4,979 research outputs found
Core structure of EAS in 10(15) to 10(17) eV
With the use of Akeno calorimeter, the attenuation of particles in concrete is analyzed as the function of the shower size of 10 to the 5th power to 10 to the 7th power. The attenuation length does not depend much on the shower size but depends a little on the shower age. The average value is approx. 150 g/sq cm for s = 0.5 to 0.85 and approx. 40 g/sq cm for s = 0.85 to 1.15. These values and their fluctuations are consistent with the equi-intensity curves of extensive air showers (EAS)
The sidereal anisotropy of cosmic rays around 3 x 10 (15) eV observed at a middle north latitude
The sidereal time variation of cosmic rays (median primary energy : 3 10 to the 15th power eV) is investigated with air shower observations at Akeno, Japan (900 m a.s.l.) which started in September 1981. Air showers are detected by a coincidence requirement on several muon detectors. The result obtained for three years is suggestive of a big semi-diurnal variation (0.37 % in amplitude). On the other hand, the diurnal variation is rather small than the semi-diurnal one. The feature of the sidereal anisotropy supposed from the present result looks quite different from that below 10 to the 14th power eV
Warm absorber, reflection and Fe K line in the X-ray spectrum of IC 4329A
Results from the X-ray spectral analysis of the ASCA PV phase observation of
the Seyfert 1 galaxy IC 4329A are presented. We find that the 0.4 - 10 keV
spectrum of IC 4329A is best described by the sum of a steep () power-law spectrum passing through a warm absorber plus a strong
reflection component and associated Fe K line, confirming recent results
(Madejski et al. 1995, Mushotsky et al. 1995). Further cold absorption in
excess of the Galactic value and covering the entire source is also required by
the data, consistent with the edge-on galactic disk and previous X-ray
measurements. The effect of the warm absorber at soft X-ray energies is best
parameterized by two absorption edges, one consistent with OVI, OVII or NVII,
the other consistent with OVIII. A description of the soft excess in terms of
blackbody emission, as observed in some other Seyfert 1 galaxies, is ruled out
by the data. A large amount of reflection is detected in both the GIS and SIS
detectors, at similar intensities. We find a strong correlation between the
amount of reflection and the photon index, but argue that the best solution
with the present data is that given by the best statistical fit. The model
dependence of the Fe K line parameters is also discussed. Our best fit gives a
slightly broad ( keV) and redshifted (E keV) Fe K line, with equivalent width 89 33 eV.
The presence of a weak Fe K line with a strong reflection can be reconciled if
one assumes iron underabundances or ionized reflection. We also have modeled
the line with a theoretical line profile produced by an accretion disk. This
yields results in better agreement with the constraints obtained from the
reflection component.Comment: Accepted for publication in The Astrophysical Journal, 10th February
1996 issue; 24 pages and 8 figures + 1 table tared, compressed and uuencoded
(with uufiles
Spectral Statistics and Luminosity Function of a Hard X-ray Complete Sample of Brightest AGNs
We investigated the statistics of the X-ray spectral properties of a complete
flux-limited sample of bright AGNs from HEAO-1 all-sky catalogs to provide the
bright end constraint of the evolution of AGN hard X-ray luminosity function
(HXLF) and the AGN population synthesis model of the X-ray background. Spectral
studies have been made using ASCA and XMM-Newton observation data for almost
all AGNs in this sample.Comment: PTPTex v0.88, 2 pages with 4 figures, Proceedings of the
"Stellar-Mass, Intermediate -Masss, and Supermassive Black Holes" in Kyoto,
Japa
A Novel Approach in Constraining Electron Spectra in Blazar Jets: The Case of Markarian 421
We report results from the observations of the well studied TeV blazar Mrk
421 with the Swift and the Suzaku satellites in December 2008. During the
observation, Mrk 421 was found in a relatively low activity state, with the
corresponding 2-10 keV flux of erg/s/cm^2. For the purpose
of robust constraining the UV-to-X-ray emission continuum we selected only the
data corresponding to truly simultaneous time intervals between Swift and
Suzaku, allowing us to obtain a good-quality, broad-band spectrum despite a
modest length (0.6 ksec) exposure. We analyzed the spectrum with the parametric
forward-fitting SYNCHROTRON model implemented in XSPEC assuming two different
representations of the underlying electron energy distribution, both well
motivated by the current particle acceleration models: a power-law distribution
above the minimum energy with an exponential cutoff at the
maximum energy , and a modified ultra-relativistic Maxwellian
with an equilibrium energy . We found that the latter implies
unlikely physical conditions within the blazar zone of Mrk 421. On the other
hand, the exponentially moderated power-law electron distribution gives two
possible sets of the model parameters: (i) flat spectrum with low minimum electron energy , and
(ii) steep spectrum with high minimum electron energy
. We discuss different interpretations of
both possibilities in the context of a diffusive acceleration of electrons at
relativistic, sub- or superluminal shocks. We also comment on how exactly the
gamma-ray data can be used to discriminate between the proposed different
scenarios.Comment: 18 pages, 2 figures; accepted for publication in the Astrophysical
Journa
Measurement of energy muons in EAS at energy region larger thean 10(17) eV
A measurement of low energy muons in extensive air showers (EAS) (threshold energies are 0.25, 0.5, 0.75 and 1.38 GeV) was carried out. The density under the concrete shielding equivalent to 0.25 GeV at core distance less than 500 m and 0.5 GeV less than 150 m suffers contamination of electromagnetic components. Therefore the thickness of concrete shielding for muon detectors for the giant air shower array is determined to be 0.5 GeV equivalence. Effects of photoproduced muons are found to be negligible in the examined ranges of shower sizes and core distances. The fluctuation of the muon density in 90 sq m is at most 25% between 200 m and 600 m from the core around 10 to the 17th power eV
Magnetic monopole search by 130 m(2)sr He gas proportional counter
A search experiment for cosmic ray magnetic monopoles was performed by means of atomic induction mechanism by using He mixture gas proportional counters of the calorimeter (130 square meters sr) at the center of the Akeno air shower array. In 3,482 hours operation no monopole candidate was observed. The upper limit of the monopole flux is 1.44 x 10 to the minus 13th power cm-z, sec -1, sr-1 (90% C.L.) for the velocity faster than 7 x 0.0001 c
Gamma rays of energy or = 10(15) eV from Cyg X-3
The experimental data of extensive air showers observed at Akeno have been analyzed to detect the gamma ray signal from Cyg X-3. After muon poor air showers are selected, the correlation of data acquisition time with 4.8 hours X-ray period is studied, giving the data concentration near the phase 0.6, the time of X-ray maximum. The probability that uniform backgrounds create the distribution is 0.2%. The time averaged integral gamma ray flux is estimated as (1.1 + or - 0.4)x 10 to the -14th power cm(-2) sec(-1) for Eo 10 to the 15th power eV and (8.8 + or - 5.0)x 10 to the 14th power cm(-2) sec(-1) for Eo 6 x 10 to the 14th power eV
- …
