100 research outputs found

    SCBC: Smart city monitoring with blockchain using Internet of Things for and neuro fuzzy procedures.

    Get PDF
    The security of the Internet of Things (IoT) is crucial in various application platforms, such as the smart city monitoring system, which encompasses comprehensive monitoring of various conditions. Therefore, this study conducts an analysis on the utilization of blockchain technology for the purpose of monitoring Internet of Things (IoT) systems. The analysis is carried out by employing parametric objective functions. In the context of the Internet of Things (IoT), it is imperative to establish well-defined intervals for job execution, ensuring that the completion status of each action is promptly monitored and assessed. The major significance of proposed method is to integrate a blockchain technique with neuro-fuzzy algorithm thereby improving the security of data processing units in all smart city applications. As the entire process is carried out with IoT the security of data in both processing and storage units are not secured therefore confidence level of monitoring units are maximized at each state. Due to the integration process the proposed system model is implemented with minimum energy conservation where 93% of tasks are completed with improved security for about 90%

    Characterizing the universal rigidity of generic frameworks

    Full text link
    A framework is a graph and a map from its vertices to E^d (for some d). A framework is universally rigid if any framework in any dimension with the same graph and edge lengths is a Euclidean image of it. We show that a generic universally rigid framework has a positive semi-definite stress matrix of maximal rank. Connelly showed that the existence of such a positive semi-definite stress matrix is sufficient for universal rigidity, so this provides a characterization of universal rigidity for generic frameworks. We also extend our argument to give a new result on the genericity of strict complementarity in semidefinite programming.Comment: 18 pages, v2: updates throughout; v3: published versio

    Normal right- and left ventricular volumes and myocardial mass in children measured by steady state free precession cardiovascular magnetic resonance

    Get PDF
    BACKGROUND: Quantification of ventricular volume by steady state free precession (SSFP) cardiovascular magnetic resonance is accurate and reproducible. Normal values exist for adults, but are lacking for children.We sought to establish normal values for left and right ventricular volumes, mass and function in healthy children by using SSFP. METHODS AND RESULTS: Fifty children (27 females, 23 males) without cardiovascular disease were evaluated. Median age was 11 years (range 7 months - 18 years), weight 35 kg (range 7-77 kg), height 146 cm (range 66-181 cm). Thirty-six examinations were performed with breath holding, 14 in freely breathing sedated children.Ventricular volumes and mass were measured in the end systolic and end diastolic phase on SSFP cine images acquired in a short axis plane as a stack of 12 contiguous slices covering full length of both ventricles. Regression analysis showed an exponential relationship between body surface area (BSA) and ventricular volumes and mass (normal value = a*BSAb). Normative curves for males and females are presented in relation to BSA for the end-diastolic volume, end-systolic volume and mass of both ventricles. Intra- and interobserver variability of the measurements was within the limits of 2% and 7% respectively, except for right ventricular mass (10%). CONCLUSION: The exponential equation for calculation of normal values for each ventricular parameter and graphical display of normative curves for data acquired in healthy children by SSFP cardiovascular magnetic resonance are provided

    High spatial resolution myocardial perfusion cardiac magnetic resonance for the detection of coronary artery disease

    Get PDF
    To evaluate the feasibility and diagnostic performance of high spatial resolution myocardial perfusion cardiac magnetic resonance (perfusion-CMR). Methods and results Fifty-four patients underwent adenosine stress perfusion-CMR. An in-plane spatial resolution of 1.4 x 1.4 mm(2) was achieved by using 5x k-space and time sensitivity encoding (k-t SENSE). Perfusion was visually graded for 16 left ventricular and two right ventricular (RV) segments on a scale from 0 = normal to 3 = abnormal, yielding a perfusion score of 0-54. Diagnostic accuracy of the perfusion score to detect coronary artery stenosis of >50% on quantitative coronary angiography was determined. Sources and extent of image artefacts were documented. Two studies (4%) were non-diagnostic because of k-t SENSE-related and breathing artefacts. Endocardial dark rim artefacts if present were small (average width 1.6 mm). Analysis by receiver-operating characteristics yielded an area under the curve for detection of coronary stenosis of 0.85 [95% confidence interval (CI) 0.75-0.95] for all patients and 0.82 (95% CI 0.65-0.94) and 0.87 (95% CI 0.75-0.99) for patients with single and multi-vessel disease, respectively. Seventy-four of 102 (72%) RV segments could be analysed. Conclusion High spatial resolution perfusion-CMR is feasible in a clinical population, yields high accuracy to detect single and multi-vessel coronary artery disease, minimizes artefacts and may permit the assessment of RV perfusion

    Electrocardiographic Criteria for Left Ventricular Hypertrophy in Children

    Get PDF
    Previous studies to determine the sensitivity of the electrocardiogram (ECG) for left ventricular hypertrophy (LVH) in children had their imperfections: they were not done on an unselected hospital population, several criteria used in adults were not applied to children, and obsolete limits of normal for the ECG parameters were used. Furthermore, left ventricular mass (LVM) was taken as the reference standard for LVH, with no regard for other clinical evidence. The study population consisted of 832 children from whom a 12-lead ECG and an M-mode echocardiogram were taken on the same day. The validity of the ECG criteria was judged on the basis of an abnormal LVM index, either alone or in combination with other clinical evidence. The ECG criteria were based on recently established age-dependent normal limits. At 95% specificity, the ECG criteria have low sensitivities (<25%) when an elevated LVM index is taken as the reference for LVH. When clinical evidence is also taken into account, the sensitivity improved considerably (<43%). Sensitivities could be further improved when ECG parameters were combined. The sensitivity of the pediatric ECG in detecting LVH is low but depends strongly on the definition of the reference used for validation

    3D Echo systematically underestimates right ventricular volumes compared to cardiovascular magnetic resonance in adult congenital heart disease patients with moderate or severe RV dilatation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Three dimensional echo is a relatively new technique which may offer a rapid alternative for the examination of the right heart. However its role in patients with non-standard ventricular size or anatomy is unclear. This study compared volumetric measurements of the right ventricle in 25 patients with adult congenital heart disease using both cardiovascular magnetic resonance (CMR) and three dimensional echocardiography.</p> <p>Methods</p> <p>Patients were grouped by diagnosis into those expected to have normal or near-normal RV size (patients with repaired coarctation of the aorta) and patients expected to have moderate or worse RV enlargement (patients with repaired tetralogy of Fallot or transposition of the great arteries). Right ventricular end diastolic volume, end systolic volume and ejection fraction were compared using both methods with CMR regarded as the reference standard</p> <p>Results</p> <p>Bland-Altman analysis of the 25 patients demonstrated that for both RV EDV and RV ESV, there was a significant and systematic under-estimation of volume by 3D echo compared to CMR. This bias led to a mean underestimation of RV EDV by -34% (95%CI: -91% to + 23%). The degree of underestimation was more marked for RV ESV with a bias of -42% (95%CI: -117% to + 32%). There was also a tendency to overestimate RV EF by 3D echo with a bias of approximately 13% (95% CI -52% to +27%).</p> <p>Conclusions</p> <p>Statistically significant and clinically meaningful differences in volumetric measurements were observed between the two techniques. Three dimensional echocardiography does not appear ready for routine clinical use in RV assessment in congenital heart disease patients with more than mild RV dilatation at the current time.</p

    Repaired tetralogy of Fallot: the roles of cardiovascular magnetic resonance in evaluating pathophysiology and for pulmonary valve replacement decision support

    Get PDF
    Surgical management of tetralogy of Fallot (TOF) results in anatomic and functional abnormalities in the majority of patients. Although right ventricular volume load due to severe pulmonary regurgitation can be tolerated for many years, there is now evidence that the compensatory mechanisms of the right ventricular myocardium ultimately fail and that if the volume load is not eliminated or reduced by pulmonary valve replacement the dysfunction might be irreversible. Cardiovascular magnetic resonance (CMR) has evolved during the last 2 decades as the reference standard imaging modality to assess the anatomic and functional sequelae in patients with repaired TOF. This article reviews the pathophysiology of chronic right ventricular volume load after TOF repair and the risks and benefits of pulmonary valve replacement. The CMR techniques used to comprehensively evaluate the patient with repaired TOF are reviewed and the role of CMR in supporting clinical decisions regarding pulmonary valve replacement is discussed

    Genetic Variants of the Renin Angiotensin System: Effects on Atherosclerosis in Experimental Models and Humans

    Get PDF
    The renin angiotensin system (RAS) has profound effects on atherosclerosis development in animal models, which is partially complimented by evidence in the human disease. Although angiotensin II was considered to be the principal effector of the RAS, a broader array of bioactive angiotensin peptides have been identified that have increased the scope of enzymes and receptors in the RAS. Genetic interruption of the synthesis of these peptides has not been extensively performed in experimental or human studies. A few studies demonstrate that interruption of a component of the angiotensin peptide synthesis pathway reduces experimental lesion formation. The evidence in human studies has not been consistent. Conversely, genetic manipulation of the RAS receptors has demonstrated that AT1a receptors are profoundly involved in experimental atherosclerosis. Few studies have reported links of genetic variants of angiotensin II receptors to human atherosclerotic diseases. Further genetic studies are needed to define the role of RAS in atherosclerosis

    Abnormal septal convexity into the left ventricle occurs in subclinical hypertrophic cardiomyopathy.

    Get PDF
    BACKGROUND: Sarcomeric gene mutations cause hypertrophic cardiomyopathy (HCM). In gene mutation carriers without left ventricular (LV) hypertrophy (G + LVH-), subclinical imaging biomarkers are recognized as predictors of overt HCM, consisting of anterior mitral valve leaflet elongation, myocardial crypts, hyperdynamic LV ejection fraction, and abnormal apical trabeculation. Reverse curvature of the interventricular septum (into the LV) is characteristic of overt HCM. We aimed to assess LV septal convexity in subclinical HCM. METHODS: Cardiovascular magnetic resonance was performed on 36 G + LVH- individuals (31 ± 14 years, 33 % males) with a pathogenic sarcomere mutation, and 36 sex and age-matched healthy controls (33 ± 12 years, 33 % males). Septal convexity (SCx) was measured in the apical four chamber view perpendicular to a reference line connecting the mid-septal wall at tricuspid valve insertion level and the apical right ventricular insertion point. RESULTS: Septal convexity was increased in G + LVH- compared to controls (maximal distance of endocardium to reference line: 5.0 ± 2.5 mm vs. 1.6 ± 2.4 mm, p ≤ 0.0001). Expected findings occurred in G + LVH- individuals: longer anterior mitral valve leaflet (23.5 ± 3.0 mm vs. 19.9 ± 3.1 mm, p ≤ 0.0001), higher relative wall thickness (0.31 ± 0.05 vs. 0.29 ± 0.04, p ≤ 0.05), higher LV ejection fraction (70.8 ± 4.3 % vs. 68.3 ± 4.4 %, p ≤ 0.05), and smaller LV end-systolic volume index (21.4 ± 4.4 ml/m(2) vs. 23.7 ± 5.8 ml/m(2), p ≤ 0.05). Other morphologic measurements (LV angles, sphericity index, and eccentricity index) were not different between G + LVH- and controls. CONCLUSIONS: Septal convexity is an additional previously undescribed feature of subclinical HCM
    corecore