88 research outputs found

    The effects of right ventricular apical pacing on left ventricular function. Stimulation of the right ventricular apex: should it still be the gold standard?

    Get PDF
    Current pacing practice is undergoing continuous and substantial changes. Initially pacing had an exclusively palliative role, since it was reserved for patients developing complete heart block or severe symptomatic bradycardia. With the appearance of novel pacing indications such as pacing for heart failure and atrial fibrillation, the effect of pacing site on cardiac function has become a critically important issue and a subject for consideration. It seems that the classical pacing site in the right ventricular apex is no longer the gold standard because of possible disadvantageous effects on cardiac function. The aim of this review article is to discuss the effect of right ventricular apical pacing on cardiac function including cellular and hemodynamic changes. We also aim to discuss the role of alternative pacing sites in the light of cardiac function

    Kamrai tachycardiák katéterablatiós kezelése

    Get PDF
    Absztrakt Az utóbbi két évtizedben a katéterablatiós technológia és az ablatiós stratégiák fejlődésével jelentős előrelépés történt a kamrai tachycardiák ablatiós kezelésében. Jelen összefoglaló közlemény célja a kamrai ritmuszavarok aktuális katéterablatiós kezelésének áttekintő ismertetése. A szerzők részletezik a katéterablatiós kezelés technikai alapjait, a kamrai tachycardiák ablatiós kezelésének javallatait és ellenjavallatait, a beavatkozás előtti és az azt követő vizsgálatokat. Ezt követően a kamrai tachycardiák csoportosításán keresztül az egyes típusok katéteres ablatiójának jellemzőit ismertetik. Ezzel párhuzamosan kitérnek az adott ritmuszavar kezelésével kapcsolatos eredményekre is. Összegzésképpen kiemelik, hogy a katéteres ablatio sikeresen alkalmazható eszközös beavatkozás a kamrai tachycardiák kezelésében. Megfelelő javallat esetén a kezelést lehetőleg minél korábban be kell iktatni a terápiás stratégiába. Orv. Hetil., 2015, 156(25), 995–1002

    Pathophysiological Mechanisms of Premature Ventricular Complexes

    Get PDF
    Premature ventricular complexes (PVCs) are the most common ventricular arrhythmia. Despite the high prevalence, the cause of PVCs remains elusive in most patients. A better understanding of the underlying pathophysiological mechanism may help to steer future research. This review aims to provide an overview of the potential pathophysiological mechanisms of PVCs and their differentiation

    Contact-Force-Sensing-Based Radiofrequency Catheter Ablation in Paroxysmal Supraventricular Tachycardias (COBRA-PATH): A randomized controlled trial

    Get PDF
    Background: Multiple studies have demonstrated the importance of adequate catheter-tissue contact in the creation of effective lesions during radiofrequency catheter ablation. The development of contact force (CF)-sensing catheters has contributed significantly to improve clinical outcomes in atrial fibrillation. However, CF-sensing technology is not used in the ablation of paroxysmal supraventricular tachycardia (PSVT). The possible reason for this is that PSVT ablation with the conventional approach (i.e. nonirrigated, non-CF-sensing catheters) is considered a relatively low-risk procedure with fairly high success rates (short and long term). The aim of this study is to determine whether CF sensing can further improve the outcomes of PSVT ablation. Methods/design: The COBRA-PATH study is a single-center, two-armed, randomized controlled trial. Patients without structural heart disease being referred for electrophysiology study, because of PSVT and potential treatment with radiofrequency (RF) catheter ablation, will be randomly assigned to either manual ablation with standard nonirrigated ablation catheters or manual ablation with an open-irrigated ablation catheter equipped with CF sensing (used in a virtual nonirrigated modus). The primary study endpoint is the difference in the number of RF applications during the ablation of atrioventricular nodal re-entry tachycardia, and that of Wolff-Parkinson-White syndrome and atrioventricular re-entrant tachycardia. Secondary outcome para

    Comparison of monophasic and biphasic shocks for transthoracic cardioversion of atrial fibrillation

    Get PDF
    OBJECTIVE: To compare the efficacy of cardioversion in patients with atrial fibrillation between monophasic damped sine waveform and rectilinear biphasic waveform shocks at a high initial energy level and with a conventional paddle position. DESIGN: Prospective randomised study. PATIENTS AND SETTING: 227 patients admitted for cardioversion of atrial fibrillation to a tertiary referral centre. RESULTS: 70

    Emerging electromagnetic interferences between implantable cardioverter-defibrillators and left ventricular assist devices: Authors' reply

    Get PDF
    Aims To investigate the prevalence of electromagnetic interference (EMI) between left ventricular assist devices (LVADs) and implantable cardioverter-defibrillators (ICDs)/pacemakers (PMs). ................................................................................................................................................................................................... Methods and results A retrospective single-centre study was conducted, including all patients undergoing HeartMate II (HMII) and HeartMate 3 (HM3) LVAD implantation (n = 106). Electromagnetic interference was determined by the inability to interrogate the ICD/PM. Overall, 85 (mean age 59 ± 8, 79% male) patients had an ICD/PM at the time of LVAD implantation; 46 patients with HMII and 40 patients with HM3. Among the 85 LVAD patients with an ICD’s/PM’s, 11 patients (13%) experienced EMI; 6 patients (15%) with an HMII and 5 patients (11%) with an HM3 (P = 0.59). Electromagnetic interference from the HMII LVADs was only present in patients with a St Jude/Abbott device; 6 of the 23 St Jude/Abbott devices. However, in the HM3 patients, EMI was mainly present in patients with Biotronik devices: 4 of the 18 with only one (1/25) patient with a Medtronic device. While initial interrogation of these devices was not successful, none of the 11 cases experienced pacing inhibition or inappropriate shocks. ................................................................................................................................................................................................... Conclusion In summary, the prevalence of EMI between ICDs in the older and newer type of LVAD’s remains rather high. While HMII patients experienced EMI with a St Jude/Abbott device (which was already known), HM3 LVAD patients experience EMI mainly with Biotronik devices. Prospective follow-up, preferably in large registries, is warranted to investigate the overall prevalence and impact of EMI in LVAD patient
    • …