131 research outputs found

    Blockchain Storage – Drive Configurations and Performance Analysis

    Get PDF
    This project will analyze the results of trials implementing various storage methods on Geth nodes to synchronize and maintain a full-archive state of the Ethereum blockchain. The purpose of these trials is to gain deeper insight to the process of lowering cost and increasing efficiency of blockchain storage using available technologies, analyzing results of various storage drives under similar conditions. It provides performance analysis and describes performance of each trial in relation to the others

    CFD Analysis of a Micro-Rotor In Ground Effect

    Get PDF
    In this work, computational fluid dynamics is used to compare experimental results for a two-bladed small rotor Out of Ground Effect and In Ground Effect conditions. The paper focuses on the evalutation and prediction of the performance of the rotor and investigates the outwash generated in ground effect. Time and phase averaged outflow velocities with two different scaling methods are compared with experiments. The results are also scaled to a full-size rotor, and compared with the PAXman model of crew operating in close rotor proximity. A particle pickup model is also used showing the dust cloud generated by the rotor

    Bilateral Ramsay Hunt syndrome in a diabetic patient

    Get PDF
    BACKGROUND: Herpes zoster oticus accounts for about 10% cases of facial palsy, which is usually unilateral and complete and full recovery occurs in only about 20% of untreated patients. Bilateral herpes zoster oticus can sometime occur in immunocompromised patients, though incidence is very rare. CASE PRESENTATION: Diabetic male, 57 year old presented to us with bilateral facial palsy due to herpes zoster oticus. Patient was having bilateral mild to moderate sensorineural hearing loss. Patient was treated with appropriate metabolic control, anti-inflammatory drugs and intravenous acyclovir. Due to uncontrolled diabetes, glucocorticoids were not used in this patient. Significant improvement in hearing status and facial nerve functions were seen in this patient. CONCLUSIONS: Herpes zoster causes severe infections in diabetic patients and can be a cause of bilateral facial palsy and bilateral Ramsay Hunt syndrome. Herpes zoster in diabetic patients should be treated with appropriate metabolic control, NSAIDS and intravenous acyclovir, which we feel should be started at the earliest. Glucocorticoids should be avoided in diabetic patients

    CFD Analysis of a Micro-Rotor In Ground Effect

    Get PDF
    In this work computational fluid dynamics is validated using experimental results for a model rotor In Ground Effect. The paper concentrates on the evaluation and prediction of the performance of the rotors and on the outwash generated In Ground Effect. Finally, safety considerations in terms of outflow forces and particles in the flow field are presented, comparing the results with other safety, distance based criteria. Using data of three different aircraft, scaling factors have been used to take into account the different size of the small-rotor studied and real case scenarios. The results show how heavier helicopters may generate the most dangerous situations, in terms of induced forces and presence of particles in a delimited area

    Evaluating the Impact of Modic Changes on Operative Treatment in the Cervical and Lumbar Spine: A Systematic Review and Meta-Analysis

    Get PDF
    Modic changes (MCs) are believed to be potential pain generators in the lumbar and cervical spine, but it is currently unclear if their presence affects postsurgical outcomes. We performed a systematic review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. All studies evaluating cervical or lumbar spine postsurgical outcomes in patients with documented preoperative MCs were included. A total of 29 studies and 6013 patients with 2688 of those patients having preoperative MCs were included. Eight included studies evaluated cervical spine surgery, eleven evaluated lumbar discectomies, nine studied lumbar fusion surgery, and three assessed lumbar disc replacements. The presence of cervical MCs did not impact the clinical outcomes in the cervical spine procedures. Moreover, most studies found that MCs did not significantly impact the clinical outcomes following lumbar fusion, lumbar discectomy, or lumbar disc replacement. A meta-analysis of the relevant data found no significant association between MCs and VAS back pain or ODI following lumbar discectomy. Similarly, there was no association between MCs and JOA or neck pain following ACDF procedures. Patients with MC experienced statistically significant improvements following lumbar or cervical spine surgery. The postoperative improvements were similar to patients without MCs in the cervical and lumbar spine

    Reasons for Transfer and Subsequent Outcomes Among Patients Undergoing Elective Spine Surgery at an Orthopedic Specialty Hospital

    Get PDF
    Objective: To evaluate the reasons for transfer as well as the 90-day outcomes of patients who were transferred from a high-volume orthopedic specialty hospital (OSH) following elective spine surgery. Materials and Methods: All patients admitted to a single OSH for elective spine surgery from 2014 to 2021 were retrospectively identified. Ninety-day complications, readmissions, revisions, and mortality events were collected and a 3:1 propensity match was conducted. Results: Thirty-five (1.5%) of 2351 spine patients were transferred, most commonly for arrhythmia (n = 7; 20%). Thirty-three transferred patients were matched to 99 who were not transferred, and groups had similar rates of complications (18.2% vs. 10.1%; P = 0.228), readmissions (3.0% vs. 4.0%; P = 1.000), and mortality (6.1% vs. 0%; P = 0.061). Conclusion: Overall, this study demonstrates a low transfer rate following spine surgery. Risk factors should continue to be optimized in order to decrease patient risks in the postoperative period at an OSH

    Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20-300 GeV/c

    Full text link
    The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.Comment: To be submitted to JINS

    Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons

    Full text link
    The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm2^2 are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation

    Biophilic architecture: a review of the rationale and outcomes

    Get PDF
    Contemporary cities have high stress levels, mental health issues, high crime levels and ill health, while the built environment shows increasing problems with urban heat island effects and air and water pollution. Emerging from these concerns is a new set of design principles and practices where nature needs to play a bigger part called “biophilic architecture”. This design approach asserts that humans have an innate connection with nature that can assist to make buildings and cities more effective human abodes. This paper examines the evidence for this innate human psychological and physiological link to nature and then assesses the emerging research supporting the multiple social, environmental and economic benefits of biophilic architecture
    corecore