577 research outputs found

    Commentary

    Get PDF

    1.6 GHz Low-Power Cross-Correlator System Enabling Geostationary Earth Orbit Aperture Synthesis

    Get PDF
    We present a 64-channel cross-correlator system for space-borne synthetic aperture imaging. Two different types of ASICs were developed to fit into this system: An 8-channel comparator ASIC implemented in a 130 nm SiGe BiCMOS process technology performs A/D conversion, while a single 64-channel digital cross-correlator ASIC implemented in a 65 nm CMOS process performs the signal processing. The digital ASIC handles 2016 cross-correlations at up to 3.6 GS/s and has a power dissipation of only 0.13 mW/correlation/GHz at a supply voltage of 1 V. The comparator ASIC can handle sample rates of at least 4.5 GS/s with a power dissipation of 47 mW/channel or 1 GS/s with a power dissipation of 17 mW/channel. The assembled system consists of a single board measuring a mere 136 x 136 mm(2) and weighing only 135 g. The assembled system demonstrates crosstalk of 0.04% between neighboring channels and stability of 800 s. We provide ASIC and system-board measurement results that demonstrate that aperture synthesis can be a viable approach for Earth observation from a geostationary Earth orbit

    Comparison of the effects of vitamin D products in a psoriasis plaque test and a murine psoriasis xenograft model

    Get PDF
    The aim of the present study was to compare the effects of Daivobet® and calcipotriol on clinical score and biomarker responses in a modified version of the Scholtz-Dumas psoriasis plaque assay. Furthermore, it was the aim to compare the effects of calcipotriol and betamethasone in the murine psoriasis xenograft model. Twenty four patients with psoriasis were treated topically once daily for three weeks, whereas the grafted mice were treated for four weeks. Clinical responses were scored twice weekly and biopsies were taken at the end of each study to analyse for skin biomarkers by histology and immunohistochemistry. The results clearly demonstrate effects on both clinical signs and biomarkers. In the patient study the total clinical score was reduced significantly with both Daivobet® and calcipotriol. Both treatments reduced epidermal thickness, Ki-67 and cytokeratin 16 expression. T cell infiltration was significantly reduced by Daivobet® but only marginally by calcipotriol. Both treatments showed strong effects on the epidermal psoriatic phenotype

    On the early stages of localised atmospheric corrosion of magnesium–aluminium alloys

    Get PDF
    The surface film on pure magnesium and two aluminium-containing magnesium alloys was characterised after 96\ua0h at 95% RH and 22\ua0\ub0C. The concentration of CO2 was carefully controlled to be either 0 or 400\ua0ppm. The exposed samples were investigated using X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, X-ray diffraction, and electron microscopy. The results showed that when the alloys were exposed to the CO2-containing environment, aluminium cations (Al3+) was incorporated into a layered surface film comprising a partially “hydrated” MgO layer followed by Mg(OH)2, and magnesium hydroxy carbonates. The results indicated that aluminium-containing magnesium alloys exhibited considerably less localised corrosion in humid air than pure magnesium. Localised corrosion in the materials under investigation was attributed to film thinning by a dissolution/precipitation mechanism

    Does right thoracotomy increase the risk of mitral valve reoperation?

    Get PDF
    ObjectiveThe study objective was to determine whether a right thoracotomy approach increases the risk of mitral valve reoperation.MethodsBetween January of 1993 and January of 2004, 2469 patients with mitral valve disease underwent 2570 reoperations (1508 replacements, 1062 repairs). The approach was median sternotomy in 2444 patients, right thoracotomy in 80 patients, and other in 46 patients. Multivariable logistic regression was used to identify factors associated with median sternotomy versus right thoracotomy, mitral valve repair versus replacement, hospital death, and stroke. Factors favoring median sternotomy (P < .03) included coronary artery bypass grafting (30% vs 2%), aortic valve replacement (39% vs 2%), tricuspid valve repair (27% vs 13%), fewer previous cardiac operations, more recent reoperation, and no prior left internal thoracic artery graft. These factors were used to construct a propensity score for risk-adjusting outcomes.ResultsHospital mortality was 6.7% (163/2444) for the median sternotomy approach and 6.3% (5/80) for the thoracotomy approach (P = .9). Risk factors (P < .04) included earlier surgery date, higher New York Heart Association class, emergency operation, multiple reoperations, and mitral valve replacement. Stroke occurred in 66 patients (2.7%) who underwent a median sternotomy and in 6 patients (7.5%) who underwent a thoracotomy (P = .006). Mitral valve replacement (vs repair) was more common in those receiving a thoracotomy (P < .04).ConclusionsCompared with median sternotomy, right thoracotomy is associated with a higher occurrence of stroke and less frequent mitral valve repair. Specific strategies for conducting the operation should be used to reduce the risk of stroke when right thoracotomy is used for mitral valve reoperation. In most instances, repeat median sternotomy, with its better exposure and greater latitude for concomitant procedures, is preferred

    A new semi-solid casting technique for fabricating SiC-reinforced Mg alloys matrix composites

    Get PDF
    The capability of the newly developed rheocasting (RC) technique in combination with the RheoMetal process for producing SiC particulate-reinforced AM50 and AZ91D matrix composites (Mg-based MMCs) was investigated. The quality of the MMCs was studied by analyzing the fraction of casting pores, number density of SiC clusters and the uniformity of SiC particles. Solid fraction, particle size and oxidation of SiC particles had strong impacts on the overall quality of the MMCs. The MMCs produced by 40% solid fraction and oxidized micron-sized SiC particles exhibited an excellent casting quality. A low-quality MMC was obtained when non-oxidized sub-micron sized SiC particles were employed. The results showed the formation of various types intermetallic particles and carbides such as MgO, Mg2Si, Al2MgC2, Mg2C3, Al4C3 as the interfacial reaction products of SiC/Mg alloy's melts. Mg hydride (alpha-MgH2) was also identified in inter-dendritic regions of the MMCs for the first time

    Results of matching valve and root repair to aortic valve and root pathology

    Get PDF
    ObjectiveFor patients with aortic root pathology and aortic valve regurgitation, aortic valve replacement is problematic because no durable bioprosthesis exists, and mechanical valves require lifetime anticoagulation. This study sought to assess outcomes of combined aortic valve and root repair, including comparison with matched bioprosthesis aortic valve replacement.MethodsFrom November 1990 to January 2005, 366 patients underwent modified David reimplantation (n = 72), root remodeling (n = 72), or valve repair with sinotubular junction tailoring (n = 222). Active follow-up was 99% complete, with a mean of 5.6 ± 4.0 years (maximum 17 years); follow-up for vital status averaged 8.5 ± 3.6 years (maximum 19 years). Propensity-adjusted models were developed for fair comparison of outcomes.ResultsThirty-day and 5-, 10-, and 15-year survivals were 98%, 86%, 74%, and 58%, respectively, similar to that of the US matched population and better than that after bioprosthesis aortic valve replacement. Propensity-score–adjusted survival was similar across procedures (P > .3). Freedom from reoperation at 30 days and 5 and 10 years was 99%, 92%, and 89%, respectively, and was similar across procedures (P > .3) after propensity-score adjustment. Patients with tricuspid aortic valves were more likely to be free of reoperation than those with bicuspid valves at 10 years (93% vs 77%, P = .002), equivalent to bioprosthesis aortic valve replacement and superior after 12 years. Bioprostheses increasingly deteriorated after 7 years, and hazard functions for reoperation crossed at 7 years.ConclusionsValve preservation (rather than replacement) and matching root procedures have excellent early and long-term results, with increasing survival benefit at 7 years and fewer reoperations by 12 years. We recommend this procedure for experienced surgical teams

    Off-label use of direct oral anticoagulants in patients receiving surgical mechanical and bioprosthetic heart valves

    Get PDF
    This cohort study assesses direct oral anticoagulant use in patients with surgical prosthetic heart valves in the United States and evaluates differences in preoperative and postoperative profiles in patients discharged while receiving direct oral anticoagulant vs warfarin
    corecore