73 research outputs found

    Sequentially Timed All-Optical Mapping Photography for Real- Time Monitoring of Laser Ablation: Breakdown and Filamentation in Picosecond and Femtosecond Regimes

    Get PDF
    To investigate ultrafast phenomena, a novel, ultrafast imaging technique was developed. Sequentially timed all-optical mapping photography (STAMP) performs single-shot image acquisition without the need for repetitive measurements and without sacrificing high-temporal resolution and image quality. The principle of this imaging method is based on the all-optical approach, and therefore it overcomes the temporal resolution in conventional high-speed cameras. Also, STAMP’s single-shot movie-shooting capability allows us to obtain sequential images of non-repetitive ultrafast dynamic phenomena. Here, we present the motion pictures of early stage dynamics during femtosecond laser ablation captured by two types of STAMP setup. Breakdown was induced by intense femtosecond laser pulse and monitored with a frame interval of 15.3 ps and a total of six frames. The movie clearly shows the plasma generation and expansion on glass surface. Also, filamentation was generated inside a glass and observed with a frame interval of 230 fs and total of 25 frames. These phenomena have previously only been observed by pump-probe imaging. STAMP is a powerful tool to understand precise processes of complex dynamics in ultrashort laser ablation

    Filtrate of Phellinus linteus Broth Culture Reduces Infarct Size Significantly in a Rat Model of Permanent Focal Cerebral Ischemia

    Get PDF
    Phellinus linteus, a natural growing mushroom, has been known to exhibit anti-tumor, anti-inflammatory, anti-allergic and anti-oxidant effects. Aiming to exploit the neuroprotective effects of P. linteus, we evaluated its effects on infarct volume reduction in a rat model of focal cerebral ischemia. Male Sprague-Dawley rats were subjected to right middle cerebral artery occlusion. Filtrate of P. linteus broth culture (various doses), fractionated filtrate (based on molecular weight) or control medium was administered intraperitoneally to rats before or after ischemia induction. Rats were killed at 24 h after the stroke surgery. Cortical and caudoputaminal infarct volumes were determined separately using an image analysis program following staining with 2,3,5-triphenyltetrazolium chloride. Significant cortical infarct volume reductions were found in the pre-treatment groups (30 and 60 minutes before onset of cerebral ischemia) compared with the control group, showing dose dependence. Posttreatment (30 minutes after ischemic onset) also significantly reduced cortical infarct volume. Furthermore, the higher molecular weight (≥12 000) fraction of the culture filtrate was more effective compared with the lower molecular weight fraction. The present findings suggest that P. linteus may be a new promising approach for the treatment of focal cerebral ischemia, with the additional benefit of a wide therapeutic time window since significant infarct volume reduction is obtained by administration even after the ischemic event. Our finding that the higher molecular weight fraction of the P. linteus culture filtrate demonstrated more prominent effect may provide a clue to identify the neuroprotective substances and mechanisms

    Cryogenic measurement of the optical absorption coefficient in sapphire crystals at 1.064(micro)m for the Large-scale Cryogenic Gravitational wave Telescope

    Get PDF
    We have applied laser calorimetry to the measurement of optical absorption in mono-crystalline sapphire at cryogenic temperatures. Sapphire is a promising candidate for the mirror substrates of the Large-scale Cryogenic Gravitational wave Telescope. The optical absorption coefficients of different sapphire samples at a wavelength of 1.064(micro)m at 5K were found to average 90ppm/cm.Comment: 8 pages, accepted to Phys. Lett.

    Reduction of thermal fluctuations in a cryogenic laser interferometric gravitational wave detector

    Full text link
    The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17\,K and 18\,K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90\,Hz to 240\,Hz by cooling the mirrors. The improved sensitivity reached a maximum of 2.2×1019m/Hz2.2 \times 10^{-19}\,\textrm{m}/\sqrt{\textrm{Hz}} at 165\,Hz.Comment: Accepted for publication in Physical Review Letters, 5 pages, 2 figure

    Conduction Effect of Thermal Radiation in a Metal Shield Pipe in a Cryostat for a Cryogenic Interferometric Gravitational Wave Detector

    Full text link
    A large heat load caused by thermal radiation through a metal shield pipe was observed in a cooling test of a cryostat for a prototype of a cryogenic interferometric gravitational wave detector. The heat load was approximately 1000 times larger than the value calculated by the Stefan-Boltzmann law. We studied this phenomenon by simulation and experiment and found that it was caused by the conduction of thermal radiation in a metal shield pipe.Comment: 7 pages, 4 figures, 2 tables, Submitted to Jpn. J. Appl. Phy

    Measurement of the mechanical loss of a cooled reflective coating for gravitational wave detection

    Full text link
    We have measured the mechanical loss of a dielectric multilayer reflective coating (ion-beam sputtered SiO2_2 and Ta2_2O5_5) in cooled mirrors. The loss was nearly independent of the temperature (4 K \sim 300 K), frequency, optical loss, and stress caused by the coating, and the details of the manufacturing processes. The loss angle was (46)×104(4 \sim 6) \times 10^{-4}. The temperature independence of this loss implies that the amplitude of the coating thermal noise, which is a severe limit in any precise measurement, is proportional to the square root of the temperature. Sapphire mirrors at 20 K satisfy the requirement concerning the thermal noise of even future interferometric gravitational wave detector projects on the ground, for example, LCGT.Comment: 8 pages, 6 figures, 3 tables : accepted version (by Physical Review D

    Current status of Japanese detectors

    Full text link
    Current status of TAMA and CLIO detectors in Japan is reported in this article. These two interferometric gravitational-wave detectors are being developed for the large cryogenic gravitational wave telescope (LCGT) which is a future plan for detecting gravitational wave signals at least once per year. TAMA300 is being upgraded to improve the sensitivity in low frequency region after the last observation experiment in 2004. To reduce the seismic noises, we are installing new seismic isolation system, which is called TAMA Seismic Attenuation System, for the four test masses. We confirmed stable mass locks of a cavity and improvements of length and angular fluctuations by using two SASs. We are currently optimizing the performance of the third and fourth SASs. We continue TAMA300 operation and R&D studies for LCGT. Next data taking in the summer of 2007 is planned. CLIO is a 100-m baseline length prototype detector for LCGT to investigate interferometer performance in cryogenic condition. The key features of CLIO are that it locates Kamioka underground site for low seismic noise level, and adopts cryogenic Sapphire mirrors for low thermal noise level. The first operation of the cryogenic interferometer was successfully demonstrated in February of 2006. Current sensitivity at room temperature is close to the target sensitivity within a factor of 4. Several observation experiments at room temperature have been done. Once the displacement noise reaches at thermal noise level of room temperature, its improvement by cooling test mass mirrors should be demonstrated.Comment: 6 pages, 5 figures, Proceedings of GWDAW-1

    Mechanosensory trichome cells evoke a mechanical stimuli–induced immune response in Arabidopsis thaliana

    Get PDF
    Perception of pathogen-derived ligands by corresponding host receptors is a pivotal strategy in eukaryotic innate immunity. In plants, this is complemented by circadian anticipation of infection timing, promoting basal resistance even in the absence of pathogen threat. Here, we report that trichomes, hair-like structures on the epidermis, directly sense external mechanical forces, including raindrops, to anticipate pathogen infections in Arabidopsis thaliana. Exposure of leaf surfaces to mechanical stimuli initiates the concentric propagation of intercellular calcium waves away from trichomes to induce defence-related genes. Propagating calcium waves enable effective immunity against pathogenic microbes through the CALMODULIN-BINDING TRANSCRIPTION ACTIVATOR 3 (CAMTA3) and mitogen-activated protein kinases. We propose an early layer of plant immunity in which trichomes function as mechanosensory cells that detect potential risks

    The genome of the versatile nitrogen fixer Azorhizobium caulinodans ORS571

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Biological nitrogen fixation is a prokaryotic process that plays an essential role in the global nitrogen cycle. <it>Azorhizobium caulinodans </it>ORS571 has the dual capacity to fix nitrogen both as free-living organism and in a symbiotic interaction with <it>Sesbania rostrata</it>. The host is a fast-growing, submergence-tolerant tropical legume on which <it>A. caulinodans </it>can efficiently induce nodule formation on the root system and on adventitious rootlets located on the stem.</p> <p>Results</p> <p>The 5.37-Mb genome consists of a single circular chromosome with an overall average GC of 67% and numerous islands with varying GC contents. Most nodulation functions as well as a putative type-IV secretion system are found in a distinct symbiosis region. The genome contains a plethora of regulatory and transporter genes and many functions possibly involved in contacting a host. It potentially encodes 4717 proteins of which 96.3% have homologs and 3.7% are unique for <it>A. caulinodans</it>. Phylogenetic analyses show that the diazotroph <it>Xanthobacter autotrophicus </it>is the closest relative among the sequenced genomes, but the synteny between both genomes is very poor.</p> <p>Conclusion</p> <p>The genome analysis reveals that <it>A. caulinodans </it>is a diazotroph that acquired the capacity to nodulate most probably through horizontal gene transfer of a complex symbiosis island. The genome contains numerous genes that reflect a strong adaptive and metabolic potential. These combined features and the availability of the annotated genome make <it>A. caulinodans </it>an attractive organism to explore symbiotic biological nitrogen fixation beyond leguminous plants.</p

    Application of sapphire bonding for suspension of cryogenic mirrors

    Get PDF
    In order to design a suspension for large cryogenic mirror, we have measured thermal conductance and shear strength of sapphire bonding in comparison with direct bonding and hydroxide-catalysis bonding. Thermal conductance per unit area of 4 [W/K/mm2] for the direct bonding and 0.3 [W/K/mm2] for the hydroxide-catalysis bonding were obtained around 20K. Shear strength of 28[MPa] for the direct bonding and 6.5 [MPa] for the hydroxide-catalysis bonding were measured at 300K. Based on those values, an estimated area that support a weight of a mirror produces a temperature step of less than 1% of a difference of temperature in between the main mirror and a mirror of Suspension Point Interferometer
    corecore