58 research outputs found

    Maternal marijuana use during lactation and infant development at one year

    Full text link
    Prenatal marijuana exposure is associated with adverse perinatal effects. Very little is known about the effect of postnatal marijuana exposure on infant development. Postnatal exposure can result from maternal use of marijuana during lactation. Delta-9-tetrahydrocannabinol (THC) transfers and concentrates in the mother's milk and is absorbed and metabolized by the nursing infant. The present study investigated the relationship between infant exposure to marijuana via the mother's milk and infant motor and mental development at one year of age. One hundred and thirty-six breast-fed infants were assessed at one year of age for motor and mental development. Sixty-eight infants were exposed to marijuana via the mother's milk. An additional 68 infants were matched to the marijuana-exposed infants on pre- and postpartum maternal alcohol and tobacco use. Marijuana exposure via the mother's milk during the first month postpartum appeared to be associated with a decrease in infant motor development at one year of age.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/28699/1/0000519.pd

    A method for exploratory repeated-measures analysis applied to a breast-cancer screening study

    Get PDF
    When a model may be fitted separately to each individual statistical unit, inspection of the point estimates may help the statistician to understand between-individual variability and to identify possible relationships. However, some information will be lost in such an approach because estimation uncertainty is disregarded. We present a comparative method for exploratory repeated-measures analysis to complement the point estimates that was motivated by and is demonstrated by analysis of data from the CADET II breast-cancer screening study. The approach helped to flag up some unusual reader behavior, to assess differences in performance, and to identify potential random-effects models for further analysis.Comment: Published in at http://dx.doi.org/10.1214/11-AOAS481 the Annals of Applied Statistics (http://www.imstat.org/aoas/) by the Institute of Mathematical Statistics (http://www.imstat.org

    Computer-assisted mammographic imaging

    Get PDF
    Computer-assisted mammography imaging comprises computer-based analysis of digitized images resulting in prompts aiding mammographic interpretation and computerized stereotactic localization devices which improve location accuracy. The commercial prompting systems available are designed to draw attention to mammographic abnormalities detected by algorithms based on symptomatic practise in North America. High sensitivity rates are important commercially but result in increased false prompt rates, which are known to distract radiologists. A national shortage of breast radiologists in the UK necessitates evaluation of such systems in a population breast screening programme to determine effectiveness in increasing cancer detection and feasibility of implementation

    Functional magnetic resonance imaging outcomes from a comprehensive magnetic resonance study of children with fetal alcohol spectrum disorders

    Get PDF
    A comprehensive neuropsychological/psychiatric, MR imaging, (MRI), MR spectroscopy (MRS), and functional MRI (fMRI) assessment was administered to children with fetal alcohol spectrum disorders (FASD) to determine if global and/or focal abnormalities could be identified, and distinguish diagnostic subclassifications across the spectrum. The four study groups included: 1. FAS/Partial FAS; 2. Static Encephalopathy/Alcohol Exposed (SE/AE); 3. Neurobehavioral Disorder/Alcohol Exposed (ND/AE); and 4. healthy peers with no prenatal alcohol exposure. fMRI outcomes are reported here. The neuropsychological/psychiatric, MRI, and MRS outcomes are reported separately. fMRI was used to assess activation in seven brain regions during performance of N-back working memory tasks. Children across the full spectrum of FASD exhibited significant working memory deficits and altered activation patterns in brain regions that are known to be involved in working memory. These results demonstrate the potential research and diagnostic value of this non-invasive MR tool in the field of FASD

    Accuracy of Digital Breast Tomosynthesis for Depicting Breast Cancer Subgroups in a UK Retrospective Reading Study (TOMMY Trial).

    Get PDF
    PURPOSE: To compare the diagnostic performance of two-dimensional (2D) mammography, 2D mammography plus digital breast tomosynthesis (DBT), and synthetic 2D mammography plus DBT in depicting malignant radiographic features. MATERIALS AND METHODS: In this multicenter, multireader, retrospective reading study (the TOMMY trial), after written informed consent was obtained, 8869 women (age range, 29-85 years; mean, 56 years) were recruited from July 2011 to March 2013 in an ethically approved study. From these women, a reading dataset of 7060 cases was randomly allocated for independent blinded review of (a) 2D mammography images, (b) 2D mammography plus DBT images, and (c) synthetic 2D mammography plus DBT images. Reviewers had no access to results of previous examinations. Overall sensitivities and specificities were calculated for younger women and those with dense breasts. RESULTS: Overall sensitivity was 87% for 2D mammography, 89% for 2D mammography plus DBT, and 88% for synthetic 2D mammography plus DBT. The addition of DBT was associated with a 34% increase in the odds of depicting cancer (odds ratio [OR] = 1.34, P = .06); however, this level did not achieve significance. For patients aged 50-59 years old, sensitivity was significantly higher (P = .01) for 2D mammography plus DBT than it was for 2D mammography. For those with breast density of 50% or more, sensitivity was 86% for 2D mammography compared with 93% for 2D mammography plus DBT (P = .03). Specificity was 57% for 2D mammography, 70% for 2D mammography plus DBT, and 72% for synthetic 2D mammography plusmDBT. Specificity was significantly higher than 2D mammography (P < .001in both cases) and was observed for all subgroups (P < .001 for all cases). CONCLUSION: The addition of DBT increased the sensitivity of 2D mammography in patients with dense breasts and the specificity of 2D mammography for all subgroups. The use of synthetic 2D DBT demonstrated performance similar to that of standard 2D mammography with DBT. DBT is of potential benefit to screening programs, particularly in younger women with dense breasts. (©) RSNA, 2015.The TOMMY Trial (a comparison of digital breast tomosynthesis with mammography in the UK Breast Screening Programme) was supported by the NIHR Health Technology Assessment Programme.This is the final published version of the article. It was originally published in Radiology (Gilbert et al., Radiology, 2015, doi:10.1148/radiol.2015142566). The final version is available at http://dx.doi.org/10.1148/radiol.201514256

    Accuracy of Digital Breast Tomosynthesis for Depicting Breast Cancer Subgroups in a UK Retrospective Reading Study (TOMMY Trial)

    Get PDF
    Purpose To compare the diagnostic performance of two-dimensional (2D) mammography, 2D mammography plus digital breast tomosynthesis (DBT), and synthetic 2D mammography plus DBT in depicting malignant radiographic features. Materials and Methods In this multicenter, multireader, retrospective reading study (the TOMMY trial), after written informed consent was obtained, 8869 women (age range, 29–85 years; mean, 56 years) were recruited from July 2011 to March 2013 in an ethically approved study. From these women, a reading dataset of 7060 cases was randomly allocated for independent blinded review of (a) 2D mammography images, (b) 2D mammography plus DBT images, and (c) synthetic 2D mammography plus DBT images. Reviewers had no access to results of previous examinations. Overall sensitivities and specificities were calculated for younger women and those with dense breasts. Results Overall sensitivity was 87% for 2D mammography, 89% for 2D mammography plus DBT, and 88% for synthetic 2D mammography plus DBT. The addition of DBT was associated with a 34% increase in the odds of depicting cancer (odds ratio [OR] = 1.34, P = .06); however, this level did not achieve significance. For patients aged 50–59 years old, sensitivity was significantly higher (P = .01) for 2D mammography plus DBT than it was for 2D mammography. For those with breast density of 50% or more, sensitivity was 86% for 2D mammography compared with 93% for 2D mammography plus DBT (P = .03). Specificity was 57% for 2D mammography, 70% for 2D mammography plus DBT, and 72% for synthetic 2D mammography plusmDBT. Specificity was significantly higher than 2D mammography (P < .001in both cases) and was observed for all subgroups (P < .001 for all cases). Conclusion The addition of DBT increased the sensitivity of 2D mammography in patients with dense breasts and the specificity of 2D mammography for all subgroups. The use of synthetic 2D DBT demonstrated performance similar to that of standard 2D mammography with DBT. DBT is of potential benefit to screening programs, particularly in younger women with dense breasts. © RSNA, 2015The TOMMY Trial (a comparison of digital breast tomosynthesis with mammography in the UK Breast Screening Programme) was supported by the NIHR Health Technology Assessment Programme.This is the final published version of the article. It was originally published in Radiology (Gilbert et al., Radiology, 2015, doi:10.1148/radiol.2015142566). The final version is available at http://dx.doi.org/10.1148/radiol.201514256

    Validation of a new fully automated software for 2D digital mammographic breast density evaluation in predicting breast cancer risk.

    Get PDF
    We compared accuracy for breast cancer (BC) risk stratification of a new fully automated system (DenSeeMammo-DSM) for breast density (BD) assessment to a non-inferiority threshold based on radiologists' visual assessment. Pooled analysis was performed on 14,267 2D mammograms collected from women aged 48-55 years who underwent BC screening within three studies: RETomo, Florence study and PROCAS. BD was expressed through clinical Breast Imaging Reporting and Data System (BI-RADS) density classification. Women in BI-RADS D category had a 2.6 (95% CI 1.5-4.4) and a 3.6 (95% CI 1.4-9.3) times higher risk of incident and interval cancer, respectively, than women in the two lowest BD categories. The ability of DSM to predict risk of incident cancer was non-inferior to radiologists' visual assessment as both point estimate and lower bound of 95% CI (AUC 0.589; 95% CI 0.580-0.597) were above the predefined visual assessment threshold (AUC 0.571). AUC for interval (AUC 0.631; 95% CI 0.623-0.639) cancers was even higher. BD assessed with new fully automated method is positively associated with BC risk and is not inferior to radiologists' visual assessment. It is an even stronger marker of interval cancer, confirming an appreciable masking effect of BD that reduces mammography sensitivity
    corecore