Design and characteristics of the prophylactic intra-operative ventricular arrhythmia ablation in high-risk LVAD candidates (PIVATAL) trial
BACKGROUND: The use of a Left Ventricular Assist Device (LVAD) in patients with advanced heart failure refractory to optimal medical management has progressed steadily over the past two decades. Data have demonstrated reduced LVAD efficacy, worse clinical outcome, and higher mortality for patients who experience significant ventricular tachyarrhythmia (VTA). We hypothesize that a novel prophylactic intra-operative VTA ablation protocol at the time of LVAD implantation may reduce the recurrent VTA and adverse events postimplant.
METHODS: We designed a prospective, multicenter, open-label, randomized-controlled clinical trial enrolling 100 patients who are LVAD candidates with a history of VTA in the previous 5 years. Enrolled patients will be randomized in a 1:1 fashion to intra-operative VTA ablation (n = 50) versus conventional medical management (n = 50) with LVAD implant. Arrhythmia outcomes data will be captured by an implantable cardioverter defibrillator (ICD) to monitor VTA events, with a uniform ICD programming protocol. Patients will be followed prospectively over a mean of 18 months (with a minimum of 9 months) after LVAD implantation to evaluate recurrent VTA, adverse events, and procedural outcomes. Secondary endpoints include right heart function/hemodynamics, healthcare utilization, and quality of life.
CONCLUSION: The primary aim of this first-ever randomized trial is to assess the efficacy of intra-operative ablation during LVAD surgery in reducing VTA recurrence and improving clinical outcomes for patients with a history of VTA
Progress report no. 4
Statement of responsibility on title-page reads: editors: M.J. Driscoll, D.D. Lanning, I. Kaplan, A.T. Supple ; contributors: A. Alvim, G.J. Brown, J.K. Chan, T.P. Choong, M.J. Driscoll, G. A. Ducat, I.A. Forbes, M.V. Gregory, S.Y. Ho, C.M. Hove, O. K. Kadiroglu, R.J. Kennerley, D.D. Lanning, J.L. Lazewatsky, L. Lederman, A.S. Leveckis, V.A. Miethe, P. A. Scheinert, A.M. Thompson, N.E. Todreas, C.P. Tzanos, and P.J. WoodIncludes bibliographical referencesProgress report; June 30, 1973U.S. Atomic Energy Commission contract: AT(11-1)225
Progress report no. 3
Statement of responsibility on title-page reads: editors: M.J. Driscoll, D.D. Lanning, I. Kaplan; contributors: S. T. Brewer, G.J. Brown, P. Delaquil, M.J. Driscoll, G.A. Ducat, I.A. Forbes, M. V. Gregory, S.Y. Ho, M.S. Kalra, C.S. Kang, L.T. Kim, D.D. Lanning, J.L. Lazewatsky, T.C. Leung, E.A. Mason, N.R. Ortiz, N.C. Rasmussen, I.C. Rickard, K.D. Roberson, A.T. Supple, A.M. Thompson, and C.P. TzanosIncludes bibliographical referencesProgress report ; June 30, 1972U.S. Atomic Energy Commission contracts: AT(11-1)306
Recommended from our members
Quantification of Left Ventricular Function With Premature Ventricular Complexes Reveals Variable Hemodynamics.
BackgroundPremature ventricular complexes (PVCs) are prevalent in the general population and are sometimes associated with reduced ventricular function. Current echocardiographic and cardiovascular magnetic resonance imaging techniques do not adequately address the effect of PVCs on left ventricular function.Methods and resultsFifteen subjects with a history of frequent PVCs undergoing cardiovascular magnetic resonance imaging had real-time slice volume quantification performed using a 2-dimensional (2D) real-time cardiovascular magnetic resonance imaging technique. Synchronization of 2D real-time imaging with patient ECG allowed for different beats to be categorized by the loading beat RR duration and beat RR duration. For each beat type, global volumes were quantified via summation over all slices covering the entire ventricle. Different patterns of ectopy, including isolated PVCs, bigeminy, trigeminy, and interpolated PVCs, were observed. Global functional measurement of the different beat types based on timing demonstrated differences in preload, stroke volume, and ejection fraction. An average of hemodynamic function was quantified for each subject depending on the frequency of each observed beat type.ConclusionsApplication of real-time cardiovascular magnetic resonance imaging in patients with PVCs revealed differential contribution of PVCs to hemodynamics