15 research outputs found

    Evaluation of Epithelial Integrity with Various Transepithelial Corneal Cross-Linking Protocols for Treatment of Keratoconus

    Get PDF
    Purpose. Corneal collagen cross-linking (CXL) has been demonstrated to stiffen cornea and halt progression of ectasia. The original protocol requires debridement of central corneal epithelium to facilitate diffusion of a riboflavin solution to stroma. Recently, transepithelial CXL has been proposed to reduce risk of complications associated with epithelial removal. Aim of the study is to evaluate the impact of various transepithelial riboflavin delivery protocols on corneal epithelium in regard to pain and epithelial integrity in the early postoperative period. Methods. One hundred and sixty six eyes of 104 subjects affected by progressive keratoconus underwent transepithelial CXL using 6 different riboflavin application protocols. Postoperatively, epithelial integrity was evaluated at slit lamp and patients were queried regarding their ocular pain level. Results. One eye had a corneal infection associated with an epithelial defect. No other adverse event including endothelial decompensation or endothelial damage was observed, except for epithelial damages. Incidence of epithelial defects varied from 0 to 63%. Incidence of reported pain varied from 0 to 83%. Conclusion. Different transepithelial cross-linking protocols have varying impacts on epithelial integrity. At present, it seems impossible to have sufficient riboflavin penetration without any epithelial disruption. A compromise between efficacy and epithelial integrity has to be found

    Altered Regulation of mRNA and miRNA Expression in Epithelial and Stromal Tissue of Keratoconus Corneas

    Get PDF
    Purpose: Evaluation of mRNA and microRNA (miRNA) expression in epithelium and stroma of patients with keratoconus. Methods: The epithelium and stroma of eight corneas of eight patients with keratoconus and eight corneas of eight non-keratoconus healthy controls were studied separately. RNA was extracted, and mRNA and miRNA analyses were performed using microarrays. Differentially expressed mRNAs and miRNAs in epithelial and stromal keratoconus samples compared to healthy controls were identified. Selected genes and miRNAs were further validated using RT-qPCR. Results: We discovered 170 epithelial and 1498 stromal deregulated protein-coding mRNAs in KC samples. In addition, in epithelial samples 180 miRNAs and in stromal samples 379 miRNAs were significantly deregulated more than twofold compared to controls. Pathway analysis revealed enrichment of metabolic and axon guidance pathways for epithelial cells and enrichment of metabolic, mitogen-activated protein kinase (MAPK), and focal adhesion pathways for stromal cells. Conclusions: This study demonstrates significant differences in the expression and regulation of mRNAs and miRNAs in the epithelium and stroma of Patients with KC. Also, in addition to the well-known target candidates, we were able to identify further genes and miRNAs that may be associated with keratoconus. Signaling pathways influencing metabolic changes and cell contacts are affected in epithelial and stromal cells of patients with keratoconus

    Inflammatory Response in the Anterior Chamber after Implantation of an Angle-Supported Lens in Phakic Myopic Eyes

    Get PDF
    Purpose. To evaluate the inflammatory reaction after implantation of an angle-supported foldable acrylic anterior chamber IOL for myopia correction over time. Methods. Adult individuals seeking vision correction with stable myopia >7.0 D were included. Exclusion criteria are anterior chamber depth <2.8 mm, insufficient endothelial cell density, other preexisting ocular conditions, and prior eye surgery. Laser flare photometry and slitlamp examination were performed before and up to 1 year after implantation of an AcrySof Cachet IOL (Alcon Laboratories, Forth Worth, TX, USA). Postoperative treatment comprised antibiotic eye-drops for 5 days and nonsteroidal anti-inflammatory eye-drops (NSAIDs) for 4 weeks. Results. Average laser flare values of 15 consecutive eyes of 15 patients were 8.3±9.7 preoperatively and 19.0±24.2 (1 day), 24.0±27.5 (1 week), 17.6±13.4 (1 month), 14.9±15.4 (3 months), and 10.0±7.0 (1 year) photon counts/ms after implantation, respectively. Slitlamp examination yielded 0 or 1+ cells (SUN classification) in every one eye throughout the follow-up period. Conclusion. Results indicate a low maximum inflammatory response and a quick recovery to a long-term safe level. The use of NSAIDs seems sufficient in routine cases, thus avoiding potential drawbacks of using corticoids

    The influence of lens position, vault prediction, and posterior cornea on phakic posterior chamber intraocular lens power.

    Get PDF
    BACKGROUND Achieving precise refractive outcomes in phakic posterior chamber intraocular lens (pIOL) implantation is crucial for patient satisfaction. This study investigates factors affecting pIOL power calculations, focusing on myopic eyes, and evaluates the potential benefits of advanced predictive models. DESIGN Retrospective, single-center, algorithm improvement study METHODS: Various variations with different effective lens position (ELP) algorithms were analyzed. The algorithms included a fixed constant model, and a multiple linear regression model and were tested with and without incorporation of the posterior corneal curvature (Rcp). Furthermore, the impact of inserting the postoperative vault, the space between the pIOL and the crystalline lens, into the ELP algorithm was examined, and a simple vault prediction model was assessed. RESULTS Integrating Rcp and the measured vault into pIOL calculations did not significantly improve accuracy. Transitioning from constant model approaches to ELP concepts based on linear regression models significantly improved pIOL power calculations. Linear regression models outperformed constant models, enhancing refractive outcomes for both ICL and IPCL pIOL platforms. CONCLUSIONS This study underscores the utility of implementing ELP concepts based on linear regression models into pIOL power calculation. Linear regression based ELP models offered substantial advantages for achieving desired refractive outcomes, especially in lower to medium power pIOL models. For pIOL power calculations in both pIOL platforms we tested with preoperative measurements from a Scheimpflug device, we found improved results with the LION 1ICL formula and LION 1IPCL formula. Further research is needed to explore the applicability of these findings to a broader range of pIOL designs and measurement devices

    Changes of Subjective Symptoms and Tear Film Biomarkers following Femto-LASIK

    No full text
    Femtosecond laser-assisted in situ keratomileusis (Femto-LASIK) represents a common treatment modality in refractive surgery and shows excellent results in terms of safety, efficacy, predictability, and long-term stability. However, patients may be affected by dry eye symptoms. The aim of this study was to identify a potential association between subjective dry eye symptoms, objective dry eye markers, and possible changes in the tear film, which could be a target for future therapy development. Therefore, clinical (dry eye) examinations (OSDI, Schirmer test, lissamine green and fluorescein staining, BUT, visual acuity) were carried out before LASIK as well as 5 and 90 days post-OP. The dry eye marker MMP-9, cytokines (IL-1&beta;, IL-8), and pain markers (NGF, CGRP) were quantified in tear samples with immunoassays. In addition, correlation analyses were performed. Clinical examinations revealed an upregulated OSDI score 5 days post-OP and an increased lissamine green staining score 90 days post-OP. Downregulated CGRP levels were noted 5 days post-OP, while other protein markers were not significantly altered after Femto-LASIK. Hence, Femto-LASIK surgery induced subjective symptoms like that of dry eye which could objectively rather be classified as Femto-LASIK-related discomfort. In the future, this could possibly be better detected and treated using pain markers such as CGRP

    Increasing depth of focus with allogeneic presbyopic inlays: 3-year results

    No full text
    PURPOSE: To demonstrate the safety and efficacy of allogenic corneal inlays designed to increase the depth of focus (DoF) in treated eyes. SETTINGS: Medipol University Hospital, Istanbul, Turkey. DESIGN: Prospective case series. METHODS: This study includes 50 eyes of 25 patients with a follow-up of 3 years. Emmetropic patients with presbyopia had implantation of allogenic corneal inlays in the nondominant eye. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and uncorrected near visual acuity (UNVA) were evaluated in all eyes. A subjective visual acuity test system (Multifocal Lens Analyzer 3.0 application) was used to analyze the DoF by measuring the defocus curves. RESULTS: No significant difference between the treated and fellow eyes in UDVA and CDVA was found, whereas UNVA was significantly better in the treated eyes ( P = .20, P = .07, P < .01, respectively). Comparing to the preoperative CDVA, there was a 1-line decrease in CDVA in 6 (%24) patients. The mean defocus curves reveal a DoF of 1.1 diopters (D) for the untreated eye at the logMAR = 0.2 threshold. By contrast, the mean DoF of the treated eye and binocularly was 2.8 D. The areas under the curve were significantly better in the near, intermediate, and total distances in the treated eyes, whereas it was better for the far distances in the untreated eyes. All values were significant ( P = .023 total, P < .01 others). CONCLUSIONS: Allogenic presbyopic inlay implantation may be safe and provided a clinically and statistically significant increase in the DoF leading to good far, intermediate, and near-visual acuity in emmetropic presbyopic patients

    Changes of subjective symptoms and tear film biomarkers following Femto-LASIK

    No full text
    Femtosecond laser-assisted in situ keratomileusis (Femto-LASIK) represents a common treatment modality in refractive surgery and shows excellent results in terms of safety, efficacy, predictability, and long-term stability. However, patients may be affected by dry eye symptoms. The aim of this study was to identify a potential association between subjective dry eye symptoms, objective dry eye markers, and possible changes in the tear film, which could be a target for future therapy development. Therefore, clinical (dry eye) examinations (OSDI, Schirmer test, lissamine green and fluorescein staining, BUT, visual acuity) were carried out before LASIK as well as 5 and 90 days post-OP. The dry eye marker MMP-9, cytokines (IL-1β\beta, IL-8), and pain markers (NGF, CGRP) were quantified in tear samples with immunoassays. In addition, correlation analyses were performed. Clinical examinations revealed an upregulated OSDI score 5 days post-OP and an increased lissamine green staining score 90 days post-OP. Downregulated CGRP levels were noted 5 days post-OP, while other protein markers were not significantly altered after Femto-LASIK. Hence, Femto-LASIK surgery induced subjective symptoms like that of dry eye which could objectively rather be classified as Femto-LASIK-related discomfort. In the future, this could possibly be better detected and treated using pain markers such as CGRP
    corecore