2,018 research outputs found
Degradation of a Multilayer Insulation Due to a Seam and a Penetration
The degradation of the thermal performance of a multilayer insulation due to the presence of a seam and a penetration was studied. The multilayer insulation had 30 aluminized Mylar radiation shields with silk net spacers. The seam, an offset butt joint, caused a heat input of 0.169 watt per meter in addition to the basic insulation thermal performance of 0.388 watt per square meter obtained before the installation of the butt joint. The penetration, a fiberglass tank support strut, provided a heat input (including the degradation of the insulation) of 0.543 watt in addition to the basic insulation thermal performance of 0.452 watt per square meter obtained before the penetration
Transient thermal performance of multilayer insulation systems during simulated ascent pressure decay
Transient thermal performance of multilayer insulation systems with liquid hydrogen tank during simulated Saturn 5 ascent pressure deca
Comparison of reusable insulation systems for cryogenically-tanked earth-based space vehicles
Three reusable insulation systems concepts were developed for use with cryogenic tanks of earth-based space vehicles. Two concepts utilized double-goldized Kapton (DGK) or double-aluminized Mylar (DAM) multilayer insulation (MLI), while the third utilized a hollow-glass-microsphere, loadbearing insulation (LBI). Thermal performance measurements were made under space-hold (vacuum) conditions for insulating warm boundary temperatures of approximately 291 K. The resulting effective thermal conductivity was approximately 0.00008 W/m-K (W = weight,Kg; m = measured; K = temperature) for the MLI systems (liquid hydrogen test results) and 0.00054 W/m-K for the LBI system (liquid nitrogen test results corrected to liquid hydrogen temperature)
Development of improved-durability plasma sprayed ceramic coatings for gas turbine engines
As part of a NASA program to reduce fuel consumption of current commercial aircraft engines, methods were investigated for improving the durability of plasma sprayed ceramic coatings for use on vane platforms in the JT9D turbofan engine. Increased durability concepts under evaluation include use of improved strain tolerant microstructures and control of the substrate temperature during coating application. Initial burner rig tests conducted at temperatures of 1010 C (1850 F) indicate that improvements in cyclic life greater than 20:1 over previous ceramic coating systems were achieved. Three plasma sprayed coating systems applied to first stage vane platforms in the high pressure turbine were subjected to a 100-cycle JT9D engine endurance test with only minor damage occurring to the coatings
EXPERIMENTAL INVESTIGATION OF THE SLOSH-DAMPING EFFECTIVENESS OF POSITIVE-EXPULSION BAGS AND DIAPHRAGMS IN SPHERICAL TANKS
Slosh damping effectiveness of positive expulsion bags and diaphragms in spherical tank
Liquid propellant reorientation in a low-gravity environment
An existing empirical analysis relating to the reorientation of liquids in cylindrical tanks due to propulsive settling in a low gravity environment was extended to include the effects of geyser formation in the Weber number range from 4 to 10. Estimates of the minimum velocity increment required to be imposed on the propellant tank to achieve liquid reorientation were made. The resulting Bond numbers, based on tank radius, were found to be in the range from 3 to 5, depending upon the initial liquid fill level, with higher Bond number required for high initial fill levels. The resulting Weber numbers, based on tank radius and the velocity of the liquid leading edge, were calculated to be in the range from 6.5 to 8.5 for cylindrical tanks having a fineness ratio of 2.0, with Weber numbers of somewhat greater values for longer cylindrical tanks. It, therefore, appeared to be advantageous to allow small geysers to form and then dissipate into the surface of the collected liquid in order to achieve the minimum velocity increment. The Bond numbers which defined the separation between regions in which geyser formation did and did not occur due to propulsive settling in a spherical tank configuration ranged from 2 to 9 depending upon the liquid fill level
Thermal performance of gaseous-helium-purged tank-mounted multilayer insulation system during ground-hold and space-hold thermal cycling and exposure to water vapor
An experimental investigation was conducted to determine (1) the ground-hold and space-hold thermal performance of a multilayer insulation (MLI) system mounted on a spherical, liquid-hydrogen propellant tank and (2) the degradation to the space-hold thermal performance of the insulation system that resulted from both thermal cycling and exposure to moisture. The propellant tank had a diameter of 1.39 meters (4.57ft). The MLI consisted of two blankets of insulation; each blanket contained 15 double-aluminized Mylar radiation shields separated by double silk net spacers. Nineteen tests simulating basic cryogenic spacecraft thermal (environmental) conditions were conducted. These tests typically included initial helium purge, liquid-hydrogen fill and ground-hold, ascent, space-hold, and repressurization. No significant degradation of the space-hold thermal performance due to thermal cycling was noted
Experimental investigation of liquid sloshing in a scale-model Centaur liquid-hydrogen tank
Liquid sloshing in scale model Centaur liquid hydrogen tan
Purging of a multilayer insulation with dacron tuft spacer by gas diffusion
The time and purge gas usage required to purge a multilayer insulation (MLI) panel with gaseous helium by means of gas diffusion to obtain a condensable gas (nitrogen) concentration of less than 1 percent within the panel are stipulated. Two different, flat, rectangular MLI panels, one incorporating a butt joint, were constructed of of 11 double-aluminized Mylar (DAM) radiation shields separated by Dacron tuft spacers. The DAM/Dacron tuft concept is known commercially as Superfloc. The nitrogen gas concentration as a function of time within the MLI panel could be adequately predicted by using a simple, one dimensional gas diffusion model in which the boundary conditions at the edge of the MLI panel were time dependent. The time and purge gas usage required to achieve 1 percent nitrogen gas concentration within the MLI panel varied from 208 to 86 minutes and 34.1 to 56.5 MLI panel purge volumes, respectively, for gaseous helium purge rates from 10 to 40 MLI panel volumes per hour
Participatory Militias: An Analysis of an Armed Movement's Online Audience
Armed groups of civilians known as "self-defense forces" have ousted the
powerful Knights Templar drug cartel from several towns in Michoacan. This
militia uprising has unfolded on social media, particularly in the "VXM"
("Valor por Michoacan," Spanish for "Courage for Michoacan") Facebook page,
gathering more than 170,000 fans. Previous work on the Drug War has documented
the use of social media for real-time reports of violent clashes. However, VXM
goes one step further by taking on a pro-militia propagandist role, engaging in
two-way communication with its audience. This paper presents a descriptive
analysis of VXM and its audience. We examined nine months of posts, from VXM's
inception until May 2014, totaling 6,000 posts by VXM administrators and more
than 108,000 comments from its audience. We describe the main conversation
themes, post frequency and relationships with offline events and public
figures. We also characterize the behavior of VXM's most active audience
members. Our work illustrates VXM's online mobilization strategies, and how its
audience takes part in defining the narrative of this armed conflict. We
conclude by discussing possible applications of our findings for the design of
future communication technologies.Comment: Participatory Militias: An Analysis of an Armed Movement's Online
Audience. Saiph Savage, Andres Monroy-Hernandez. CSCW: ACM Conference on
Computer-Supported Cooperative Work 201
- …