1,221 research outputs found

    Loci Controlling Resistance to High Plains Virus and Wheat Streak Mosaic Virus in a B73 × Mo17 Population of Maize

    Get PDF
    High Plains disease has the potential to cause significant yield loss in susceptible corn (Zea mays L.) and wheat (Triticum aestivum L.) genotypes, especially in the central and western USA. The primary causal agent, High Plains virus (HPV), is vectored by wheat curl mite (WCM; Aceria tossicheila Keifer), which is also the vector of wheat streak mosaic virus (WSMV). In general, the two diseases occur together as a mixed infection in the field. The objective of this research was to characterize the inheritance of HPV and WSMV resistance using B73 (resistant to HPV and WSMV) × Mo17 (moderately susceptible to HPV and WSMV) recombinant inbred lines. A population of 129 recombinant inbred lines scored for 167 molecular markers was used to evaluate resistance to WSMV and to a mixed infection of WSMV and HPV. Loci conferring resistance to systemic movement of WSMV in plants mapped to chromosomes 3, 6, and 10, consistent with the map position of wsm2, wsm1, and wsm3, respectively. Major genes for resistance to systemic spread of HPV in doubly infected plants mapped to chromosomes 3 and 6, coincident or tightly linked with the WSMV resistance loci. Analysis of doubly infected plants revealed that chromosome 6 had a major effect on HPV resistance, consistent with our previous analysis of B73 × W64A and B73 × Wf9 populations. Quantitative trait loci (QTL) affecting resistance to localized symptom development mapped to chromosomes 4 (umc66), 5 (bnl5.40), and 6 (umc85), and accounted for 24% of the phenotypic variation. Localized symptoms may reflect the amount of mite feeding or the extent of virus spread at the point of infection. Identification of cosegregating markers may facilitate selection for HPV and WSMV resistance in corn breeding programs

    Ultra-high-resolution 3D imaging of atherosclerosis in mice with synchrotron differential phase contrast: a proof of concept study.

    Get PDF
    The goal of this study was to investigate the performance of 3D synchrotron differential phase contrast (DPC) imaging for the visualization of both macroscopic and microscopic aspects of atherosclerosis in the mouse vasculature ex vivo. The hearts and aortas of 2 atherosclerotic and 2 wild-type control mice were scanned with DPC imaging with an isotropic resolution of 15 μm. The coronary artery vessel walls were segmented in the DPC datasets to assess their thickness, and histological staining was performed at the level of atherosclerotic plaques. The DPC imaging allowed for the visualization of complex structures such as the coronary arteries and their branches, the thin fibrous cap of atherosclerotic plaques as well as the chordae tendineae. The coronary vessel wall thickness ranged from 37.4 ± 5.6 μm in proximal coronary arteries to 13.6 ± 3.3 μm in distal branches. No consistent differences in coronary vessel wall thickness were detected between the wild-type and atherosclerotic hearts in this proof-of-concept study, although the standard deviation in the atherosclerotic mice was higher in most segments, consistent with the observation of occasional focal vessel wall thickening. Overall, DPC imaging of the cardiovascular system of the mice allowed for a simultaneous detailed 3D morphological assessment of both large structures and microscopic details

    Robust volume-targeted balanced steady-state free-precession coronary magnetic resonance angiography in a breathhold at 3.0 Tesla: a reproducibility study.

    Get PDF
    BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period

    Spatially selective implementation of the adiabatic T2 prep sequence for magnetic resonance angiography of the coronary arteries.

    Get PDF
    In coronary magnetic resonance angiography, a magnetization-preparation scheme for T2 -weighting (T2 Prep) is widely used to enhance contrast between the coronary blood-pool and the myocardium. This prepulse is commonly applied without spatial selection to minimize flow sensitivity, but the nonselective implementation results in a reduced magnetization of the in-flowing blood and a related penalty in signal-to-noise ratio. It is hypothesized that a spatially selective T2 Prep would leave the magnetization of blood outside the T2 Prep volume unaffected and thereby lower the signal-to-noise ratio penalty. To test this hypothesis, a spatially selective T2 Prep was implemented where the user could freely adjust angulation and position of the T2 Prep slab to avoid covering the ventricular blood-pool and saturating the in-flowing spins. A time gap of 150 ms was further added between the T2 Prep and other prepulses to allow for in-flow of a larger volume of unsaturated spins. Consistent with numerical simulation, the spatially selective T2 Prep increased in vivo human coronary artery signal-to-noise ratio (42.3 ± 2.9 vs. 31.4 ± 2.2, n = 22, P < 0.0001) and contrast-to-noise-ratio (18.6 ± 1.5 vs. 13.9 ± 1.2, P = 0.009) as compared to those of the nonselective T2 Prep. Additionally, a segmental analysis demonstrated that the spatially selective T2 Prep was most beneficial in proximal and mid segments where the in-flowing blood volume was largest compared to the distal segments. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc

    Single breath-hold slice-following CSPAMM myocardial tagging

    Get PDF
    Myocardial tagging has shown to be a useful magnetic resonance modality for the assessment and quantification of local myocardial function. Many myocardial tagging techniques suffer from a rapid fading of the tags, restricting their application mainly to systolic phases of the cardiac cycle. However, left ventricular diastolic dysfunction has been increasingly appreciated as a major cause of heart failure. Subtraction based slice-following CSPAMM myocardial tagging has shown to overcome limitations such as fading of the tags. Remaining impediments, to this technique, however, are extensive scanning times (∼10 min), the requirement of repeated breath-holds using a coached breathing pattern, and the enhanced sensitivity of artifacts related to poor patient compliance or inconsistent depths of end-expiratory breath-holds. We therefore propose a combination of slice-following CSPAMM myocardial tagging with a segmented EPI imaging sequence. Together with an optimized RF excitation scheme, this enables to acquire as many as 20 systolic and diastolic grid-tagged images per cardiac cycle with a high tagging contrast during a short period of sustained respiratio

    Management of pelvic lymphoceles after radical prostatectomy: A multicentre community based study

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Pelvic lymphoceles (LC) following radical prostatectomy (LC-RP) have an incidence up to 27%. LC-managements constitute 50% of surgical interventions performed in post-RP patients.</p> <p>Objectives</p> <p>To describe a therapeutic algorithm for LC-managements based on a community based representative retrospective study.</p> <p>Patients and methods: Multicentre data from 304 patients with LC-RP were retrospectively examined for LC-managements. RPs were performed by various surgeons from 67 urological departments. All patients had undergone 3 weeks rehabilitation in a specialized hospital where the data base was generated. Indications and results of therapeutic manoeuvres were used to develop a general concept for planning therapy decisions.</p> <p>Results</p> <p>Median age was 64 years. Complications occurred in 9% (28/304) of patients. Median LC-volume was 36 ml (range 20-1800 ml). There were more complications for LCs with ≥100 ml volume than those < 100 ml (27% versus 17%, p = 0.346). Conservative therapy was the standard in uncomplicated cases (87%, 239 of 276 patients), while intervention was done in 13% (puncture and/or drainage, surgery). Surgical intervention was performed significantly more often in complicated cases (82%, 23 from 28 patients; p < 0.001). Based on these data, LCs can be stratified into 3 groups depending on the size and clinical presentation. Therapeutic decisions were used to develop the illustrated new therapy algorithm.</p> <p>Conclusions</p> <p>This study based treatment algorithm provides a rationale approach with an accurate LC-classification as regard the indications and decision making for the available LC-RP-therapies. This could facilitate management decisions. Evaluation of this concept prospectively in large patient cohort is mandatory.</p

    Climate sensitivity of radiative impacts from transport systems

    Get PDF
    Comparing individual components of a total climate impact is traditionally done in terms of radiative forcing. However, the climate impact of transport systems includes contributions that are likely to imply climate sensitivity parameters distinctly different from the “reference value” for a homogeneous CO2 perturbation. We propose to introduce efficacy factors for each component into the assessment. The way of proceeding is illustrated using aviation as an example, and prospects for evaluating the other transport system in the EU project QUANTIFY are given
    corecore