28 research outputs found

    Hybrid debranching and TEVAR of the aortic arch off-pump, in re-do patients with complicated chronic type-A aortic dissections : a critical report

    Get PDF
    Background: Patients suffering from acute type A aortic dissection undergo replacement of the ascending aorta, the proximal hemiarch or complete aortic arch, depending on the extent of the individual pathology. In a subset of these treated patients, secondary pathologies of the distal anastomosis or the remaining distal part of the aorta occur. The treatment of these pathologies is challenging, requiring major surgical re-do procedures with aortic arch replacement under extracorporeal circulation and hypothermic circulatory arrest. Methods: We report our experience of five patients with complex aortic pathologies after previous aortic surgery treated with a single stage re-do hybrid procedure, consisting of bypass grafting of the supraaortic branches off-pump, stent graft placement for endovascular aortic repair (TEVAR) and surgical debranching of the aortic arch. Results: In all patients the surgical vascular grafts and stent grafts were deployed successfully, there were no intraoperative deaths. Four out of five patients were discharged from hospital in good clinical condition. One patient died postoperatively due to cardiac tamponade. In one patient a type I endoleak persisted leading to occlusion of a bypass branch requiring surgical revision at one year after debranching. Conclusion: We discuss the prerequisites, all steps and potential pitfalls of this hybrid aortic arch replacement. The current procedure avoids cardiopulmonary bypass and circulatory arrest, which may benefit early patient outcome; however, patient and device selection plays a key role for immediate success and midterm outcomes. In addition, precise procedural planning and development of customized stents may help to develop this procedure into a true alternative for conventional aortic arch replacement

    Durability of mitral valve reconstruction using the cosgrove edwards annuloplasty band at 5 years : From 23rd World Congress of the World Society of Cardio-Thoracic Surgeons. Split, Croatia. 12-15 September 2013

    Get PDF
    Oral presentation: 23rd World Congress of the World Society of Cardio-Thoracic Surgeons. Split, Croatia. 12-15 September 2013. Background: In the past, questions have been raised, whether an open flexible annuloplasty band can reliably prevent recurrent mitral valve regurgitation. The purpose of this study was to evaluate the durability of mitral valve repair at midterm, using the Cosgrove-Edwards annuloplasty band in a homogenic patient cohort. Methods: From January 2004 to December 2007, 157 consecutive patients with degenerative mitral valve disease were included in the study. All had quadrangular resection of a P2 prolapse and annuloplasty with a Cosgrove-Edwards annuloplasty band. Clinical and echocardiography follow-up was complete. Results: There was no intraoperative or 30 day mortality. After a mean follow-up of 5.0 ± 1.9 years, survival was 94.3%. At midterm, freedom from reoperations was 98.9%, freedom from thromboembolism was 97.5% and freedom from endocarditis was 99.4%. Echocardiography follow-up showed recurrent mitral valve regurgitation higher than grade 2 in two patients. Mean ejection fraction was 60.3 ± 10.2%, left atrial diameter was 42 ± 7 mm, mean gradient was 3.2 ± 1.4 mmHg, effective orifice area was 3.3 ± 1.3cm², mitral leaflet coaptation length was 7.5 ± 1.9 mm and mitral leaflet tethering height was 6.2 ± 2.3 mm. Conclusion: Mitral valve repair using the Cosgrove annuloplasty band for degenerative mitral valve disease provides an effective and durable form of reconstruction

    Empirical Evidence on Inflation and Unemployment in the Long Run

    Get PDF
    We examine the relationship between inflation and unemployment in the long run, using quarterly US data from 1952 to 2010. Using a band-pass filter approach, we find strong evidence that a positive relationship exists, where inflation leads unemployment by some 3 to 3 1/2 years, in cycles that last from 8 to 25 or 50 years. Our statistical approach is atheoretical in nature, but provides evidence in accordance with the predictions of Friedman (1977) and the recent New Monetarist model of Berentsen, Menzio, and Wright (2011): the relationship between inflation and unemployment is positive in the long run

    Patterns of Alcohol Consumption Among Individuals With Alcohol Use Disorder During the COVID-19 Pandemic and Lockdowns in Germany

    Get PDF
    Importance Alcohol consumption (AC) leads to death and disability worldwide. Ongoing discussions on potential negative effects of the COVID-19 pandemic on AC need to be informed by real-world evidence. Objective To examine whether lockdown measures are associated with AC and consumption-related temporal and psychological within-person mechanisms. Design, Setting, and Participants This quantitative, intensive, longitudinal cohort study recruited 1743 participants from 3 sites from February 20, 2020, to February 28, 2021. Data were provided before and within the second lockdown of the COVID-19 pandemic in Germany: before lockdown (October 2 to November 1, 2020); light lockdown (November 2 to December 15, 2020); and hard lockdown (December 16, 2020, to February 28, 2021). Main Outcomes and Measures Daily ratings of AC (main outcome) captured during 3 lockdown phases (main variable) and temporal (weekends and holidays) and psychological (social isolation and drinking intention) correlates. Results Of the 1743 screened participants, 189 (119 [63.0%] male; median [IQR] age, 37 [27.5-52.0] years) with at least 2 alcohol use disorder (AUD) criteria according to the Diagnostic and Statistical Manual of Mental Disorders (Fifth Edition) yet without the need for medically supervised alcohol withdrawal were included. These individuals provided 14 694 smartphone ratings from October 2020 through February 2021. Multilevel modeling revealed significantly higher AC (grams of alcohol per day) on weekend days vs weekdays (β = 11.39; 95% CI, 10.00-12.77; P < .001). Alcohol consumption was above the overall average on Christmas (β = 26.82; 95% CI, 21.87-31.77; P < .001) and New Year’s Eve (β = 66.88; 95% CI, 59.22-74.54; P < .001). During the hard lockdown, perceived social isolation was significantly higher (β = 0.12; 95% CI, 0.06-0.15; P < .001), but AC was significantly lower (β = −5.45; 95% CI, −8.00 to −2.90; P = .001). Independent of lockdown, intention to drink less alcohol was associated with lower AC (β = −11.10; 95% CI, −13.63 to −8.58; P < .001). Notably, differences in AC between weekend and weekdays decreased both during the hard lockdown (β = −6.14; 95% CI, −9.96 to −2.31; P = .002) and in participants with severe AUD (β = −6.26; 95% CI, −10.18 to −2.34; P = .002). Conclusions and Relevance This 5-month cohort study found no immediate negative associations of lockdown measures with overall AC. Rather, weekend-weekday and holiday AC patterns exceeded lockdown effects. Differences in AC between weekend days and weekdays evinced that weekend drinking cycles decreased as a function of AUD severity and lockdown measures, indicating a potential mechanism of losing and regaining control. This finding suggests that temporal patterns and drinking intention constitute promising targets for prevention and intervention, even in high-risk individuals

    Left ventricular non-compaction cardiomyopathy and left ventricular assist device: a word of caution

    No full text
    BACKGROUND: In patients with left ventricular non-compaction (LVNC), implantation of a left ventricular assist device (LVAD) may be performed as a bridge to transplantation. In this respect, the particular characteristics of the left ventricular myocardium may represent a challenge. CASE PRESENTATION: We report a patient with LVNC who required urgent heart transplantation for inflow cannula obstruction nine months after receiving a LVAD. LVAD parameters, echocardiography and examination of the explanted heart suggested changes of left ventricular configuration brought about by LVAD support as the most likely cause of inflow cannula obstruction. CONCLUSIONS: We conclude that changes experienced by non-compacted myocardium during LVAD support may give rise to inflow cannula obstruction and flow reduction. Presence of LVNC mandates tight surveillance for changes in LV configuration and LVAD flow characteristics and may justify urgent transplantation listing status

    Identification of factors influencing cumulative long-term radiation exposure in patients undergoing EVAR

    Get PDF
    Patients who undergo endovascular repair of aortic aneurysms (EVAR) require life-long surveillance because complications including, in particular, endoleaks, aneurysm rupture, and graft dislocation are diagnosed in a certain share of the patient population and may occur at any time after the original procedure. Radiation exposure in patients undergoing EVAR and post-EVAR surveillance has been investigated by previous authors. Arriving at realistic exposure data is essential because radiation doses resulting from CT were shown to be not irrelevant. Efforts directed at identification of factors impacting the level of radiation exposure in both the course of the EVAR procedure and post-EVAR endovascular interventions and CTAs are warranted as potentially modifiable factors may offer opportunities to reduce the radiation. In the light of the risks found to be associated with radiation exposure and considering the findings above, those involved in EVAR and post-EVAR surveillance should aim at optimal dose management

    Kinetics of circulating endothelial progenitor cells in patients undergoing carotid artery surgery

    No full text
    Aim: Endothelial progenitor cells (EPCs) are primitive cells found in the bone marrow and peripheral blood (PB). In particular, the potential of EPCs to differentiate into mature endothelial cells remains of high interest for clinical applications such as bio-functionalized patches for autologous seeding after implantation. The objective of this study was to determine EPCs’ kinetics in patients undergoing carotid artery thromboendarterectomy (CTEA) and patch angioplasty. Methods: Twenty CTEA patients were included (15 male, mean age 76 years). PB samples were taken at 1 day preoperatively, and at 1, 3, and 5 days postoperatively. Flow cytometric analysis was performed for CD34, CD133, KDR, and CD45. Expression of KDR, SDF-1α, and G-CSF was analyzed by means of enzyme-linked immunosorbent assay. Results: Fluorescence-activated cell sorting analysis revealed 0.031%±0.016% (% of PB mononuclear cells) KDR+ cells and 0.052%±0.022% CD45-/CD34+/CD133+ cells, preoperatively. A 33% decrease of CD45–/CD34+/CD133+ cells was observed at day 1 after surgery. However, a relative number (compared to initial preoperative values) of CD45-/CD34+/CD133+ cells was found on day 3 (82%) and on day 5 (94%) postoperatively. More profound upregulated levels of CD45–CD34+/CD133+ cells were observed for diabetic (+47% compared to nondiabetic) and male (+38% compared to female) patients. No significant postoperative time-dependent differences were found in numbers of KDR+ cells and the concentrations of the cytokines KDR and G-CSF. However, the SDF-1α levels decreased significantly on day 1 postoperatively but returned to preoperative levels by day 3. Conclusion: CTEA results in short-term downregulation of circulating EPCs and SDF-1α levels. Rapid return to baseline levels might indicate participation of EPCs in repair mechanisms following vascular injury
    corecore