12 research outputs found

    HIV-2 Integrase Variation in Integrase Inhibitor-NaĂŻve Adults in Senegal, West Africa

    Get PDF
    Antiretroviral therapy for HIV-2 infection is hampered by intrinsic resistance to many of the drugs used to treat HIV-1. Limited studies suggest that the integrase inhibitors (INIs) raltegravir and elvitegravir have potent activity against HIV-2 in culture and in infected patients. There is a paucity of data on genotypic variation in HIV-2 integrase that might confer intrinsic or transmitted INI resistance.We PCR amplified and analyzed 122 HIV-2 integrase consensus sequences from 39 HIV-2-infected, INI-naive adults in Senegal, West Africa. We assessed genetic variation and canonical mutations known to confer INI-resistance in HIV-1.No amino acid-altering mutations were detected at sites known to be pivotal for INI resistance in HIV-1 (integrase positions 143, 148 and 155). Polymorphisms at several other HIV-1 INI resistance-associated sites were detected at positions 72, 95, 125, 154, 165, 201, 203, and 263 of the HIV-2 integrase protein.Emerging genotypic and phenotypic data suggest that HIV-2 is susceptible to the new class of HIV integrase inhibitors. We hypothesize that intrinsic HIV-2 integrase variation at "secondary" HIV-1 INI-resistance sites may affect the genetic barrier to HIV-2 INI resistance. Further studies will be needed to assess INI efficacy as part of combination antiretroviral therapy in HIV-2-infected patients

    Prevalence and correlates of beta human papillomavirus detection in fingernail samples from mid-adult women

    No full text
    Cutaneous human papillomaviruses (HPVs) have not been evaluated in fingernails from healthy individuals. To determine prevalence and correlates of β-HPVs in fingernails from healthy mid-adult women, we tested archived samples collected from 2011 to 2012 using a multiplex PCR combined with Luminex technology for 46 β-HPV genotypes. One hundred thirteen (61.1%) of 185 fingernail samples were positive for β-HPV, and the median number of types detected in positive samples was 2 (interquartile range: 1–4). The most common genotypes detected were HPV-23 (β−2) (13.5%), HPV-38 (β−2) (13.0%), HPV-5 (β−1) (9.2%), HPV-107 (β−2) (8.7%), and HPV-120 (β−2) (8.7%). In multivariate analysis, β-HPV detection was associated with age (prevalence ratio [PR] for women 40–51 years versus 30–39 years = 1.30, 95% CI: 1.05–1.62) and race (PR for non-white versus white race = 0.65, 95% CI: 0.45–0.94). The prevalence of β-HPV in fingernail samples from healthy mid-adult women was similar to the prevalence of β-HPV reported at other cutaneous sites in prior studies. We did not identify any significant health or sexual behavior predictors of β-HPV detection in fingernails. Our results support the hypothesis that fingers may serve as a source of transmission or autoinoculation of cutaneous HPVs to other anatomic sites. Keywords: Fingernails, Women, Beta-HPV, Prevalence, Mid-adult, Risk facto

    Development and Evaluation of a Liquid Bead Microarray Assay for Genotyping Genital Human Papillomaviruses▿ †

    No full text
    We developed a liquid bead microarray (LBMA) assay for genotyping genital human papillomaviruses (HPVs) based on the MY09-MY11-HMB01 PCR system and the reverse line blot (RLB) assay probe sequences. Using individual HPV plasmids, we were able to detect as few as 50 copies per reaction. In two separate retrospective studies, the LBMA assay was compared to the RLB assay and to the Hybrid Capture II (hc2) assay. Testing was performed without knowledge of other assay results. In the first study, 614 cervical swab samples (enriched for HPV infection) from 160 young women were tested for HPV DNA, and 360 (74.8%) type-specific HPV infections were detected by both assays, 71 (14.8%) by the LBMA assay only, and 50 (10.4%) by the RLB assay only. Type-specific agreement for the two assays was excellent (99.1%; kappa = 0.85; 95% confidence interval [95% CI], 0.82 to 0.88). Samples with discrepant LBMA and RLB test results tended to have low viral loads by a quantitative type-specific PCR assay. In the second study, cervical swab samples from 452 women (including 54 women with histologically confirmed cervical-intraepithelial neoplasia grade 2 or worse [≥CIN2]) were tested initially by the hc2 and subsequently by the LBMA assay. The estimated sensitivities for ≥CIN2 were similar for the LBMA and hc2 assays (98.4% [95% CI, 95.0 to 100%] and 95.6% [95% CI, 89.2 to 100%], respectively). The percentages of negative results among 398 women without ≥CIN2 were similar for the LBMA and hc2 assays (45% and 50%, respectively). The repeat test reproducibility for 100 samples was 99.1% (kappa = 0.92; 95% CI, 0.90 to 0.95). We conclude that the new LBMA assay will be useful for clinical and epidemiological research

    Evaluation of Transported Dry and Wet Cervical Exfoliated Samples for Detection of Human Papillomavirus Infection▿

    No full text
    We determined the feasibility of human papillomavirus (HPV) detection in cervical exfoliated cells collected as dry swab samples. Both dry cervical swab and specimen transport medium (STM) cervical swab samples were collected from 135 patients attending either colposcopy or women's clinics in Guayaquil, Ecuador, who had a cytology diagnosis within 6 months. HPV was detected by dot blot hybridization and genotyped by the liquid bead microarray assay (LBMA). Overall, 23.1% of dry samples were positive for any high-risk HPV types, and 24.6% of STM samples were positive for any high-risk HPV types. Of 125 paired samples, the type-specific high-risk HPV proportion positive agreement was 60.7% (kappa, 0.69; 95% confidence interval [CI], 0.53 to 0.82). Of six women with cytological evidence of invasive cervical cancer, high-risk HPV DNA was detected in three of their STM samples and in five of their dry samples. Dry samples were more likely to be insufficient for HPV testing than STM samples. Consistent with this observation, the amount of genomic DNA quantitated with the β-actin gene was almost 20 times lower in dry samples than in STM samples when detected by the real-time TaqMan assay; however, HPV DNA viral loads in dry samples were only 1.6 times lower than those in matched STM samples. We concluded that exfoliated cervical cells could be collected as dry swab samples for HPV detection
    corecore