1,252 research outputs found
On the spin modulated circular polarization from the intermediate polars NY Lup and IGRJ1509-6649
We report on high time resolution, high signal/noise, photo-polarimetry of
the intermediate polars NY Lup and IGRJ1509-6649. Our observations confirm the
detection and colour dependence of circular polarization from NY Lup and
additionally show a clear white dwarf, spin modulated signal. From our new high
signal/noise photometry we have unambiguously detected wavelength dependent
spin and beat periods and harmonics thereof. IGRJ1509-6649 is discovered to
also have a particularly strong spin modulated circularly polarized signal. It
appears double peaked through the I filter and single peaked through the B
filter, consistent with cyclotron emission from a white dwarf with a relatively
strong magnetic field.
We discuss the implied accretion geometries in these two systems and any
bearing this may have on the possible relationship with the connection between
polars and soft X-ray-emitting IPs. The relatively strong magnetic fields is
also suggestive of them being polar progenitors.Comment: 8 pages, 6 figures and 1 table. Accepted for publication in MNRA
Clouded leopard phylogeny revisited: support for species recognition and population division between Borneo and Sumatra
This is an Open Access article distributed under the terms of the Creative Commons Attribution Licens
Simultaneous optical polarimetry and X-ray data of the near synchronous polar RX J2115-5840
We present simultaneous optical polarimetry and X-ray data of the near
synchronous polar RX J2115-5840. We model the polarisation data using the
Stokes imaging technique of Potter et al. We find that the data are best
modelled using a relatively high binary inclination and a small angle between
the magnetic and spin axes. We find that for all spin-orbit beat phases, a
significant proportion of the accretion flow is directed onto the lower
hemisphere of the white dwarf, producing negative circular polarisation. Only
for a small fraction of the beat cycle is a proportion of the flow directed
onto the upper hemisphere. However, the accretion flow never occurs near the
upper magnetic pole, whatever the orientation of the magnetic poles. This
indicates the presence of a non-dipole field with the field strength at the
upper pole significantly higher. We find that the brightest parts of the hard
X-ray emitting region and the cyclotron region are closely coincident.Comment: 9 pages, accepted for publication in MNRAS 2 March 200
Randomized controlled trial of intravenous antivenom versus placebo for latrodectism: the second redback antivenom evaluation (RAVE- II) study.
Objective: Latrodectism is the most important spider envenomation syndrome worldwide. There remains considerable controversy over antivenom treatment. We aimed to investigate whether antivenom resulted in resolution of pain and systemic effects in patients with latrodectism given standardized analgesia. Methods: In a multicentre randomized placebo-controlled trial of redback spider antivenom for latrodectism, 224 patients (>7yr) with a redback spider-bite and severe pain with or without systemic effects were randomized to receive normal saline (placebo) or antivenom, after receiving standardized analgesia. The primary outcome was a clinically significant reduction in pain 2 hours after trial medication compared to baseline. A second primary outcome for the subgroup with systemic features of envenomation was resolution of systemic features at 2 hours. Secondary outcomes were improved pain at 4 and 24 hours, resolution of systemic features at 4 hours, administration of opioid analgesics or unblinded antivenom after 2 hours and adverse reactions. Results: Two hours after treatment, 26/112 patients (23%) from the placebo arm had a clinically significant improvement in pain versus 38/112 (34%) from the antivenom arm (difference in favor of antivenom 10.7%;95%CI:−1.1% to +22.6%;p=0.10). Systemic 2 effects resolved after two hours in 9/41 patients (22%) in the placebo arm and 9/35 (26%) in the antivenom arm (difference 3.8%;95%CI:−15% to +23%;p=0.79). There was no significant difference in any secondary outcome between antivenom and placebo. Acute systemic hypersensitivity reactions occurred in 4/112 (3.6%) patients given antivenom. Conclusions: The addition of antivenom to standardized analgesia in patients with latrodectism, did not significantly improve pain or systemic effects.NHMRC 54522
Stokes imaging, Doppler mapping and Roche tomography of the AM Her system V834 Cen
We report on new simultaneous phase resolved spectroscopic and polarimetric
observations of the polar (AM Herculis star) V834 Cen during a high state of
accretion. Strong emission lines and high levels of variable circular and
linear polarization are observed over the orbital period. The polarization data
is modelled using the Stokes imaging technique of Potter et al. The
spectroscopic emission lines are investigated using the Doppler tomography
technique of Marsh and Horne and the Roche tomography technique of Dhillon and
Watson. Up to now all three techniques have been used separately to investigate
the geometry and accretion dynamics in Cataclysmic Variables. For the first
time, we apply all three techniques to simultaneous data for a single system.
This allows us to compare and test each of the techniques against each other
and hence derive a better understanding of the geometry, dynamics and system
parameters of V834 Cen.Comment: 10 pages, 8 figures; Accepted for publication in MNRA
- …