5 research outputs found

    AI-assisted capsule endoscopy reading in suspected small bowel bleeding : a multicentre prospective study

    Get PDF
    Capsule endoscopy reading is time consuming, and readers are required to maintain attention so as not to miss significant findings. Deep convolutional neural networks can recognise relevant findings, possibly exceeding human performances and reducing the reading time of capsule endoscopy. Our primary aim was to assess the non-inferiority of artificial intelligence (AI)-assisted reading versus standard reading for potentially small bowel bleeding lesions (high P2, moderate P1; Saurin classification) at per-patient analysis. The mean reading time in both reading modalities was evaluated among the secondary endpoints.Patients aged 18 years or older with suspected small bowel bleeding (with anaemia with or without melena or haematochezia, and negative bidirectional endoscopy) were prospectively enrolled at 14 European centres. Patients underwent small bowel capsule endoscopy with the Navicam SB system (Ankon, China), which is provided with a deep neural network-based AI system (ProScan) for automatic detection of lesions. Initial reading was performed in standard reading mode. Second blinded reading was performed with AI assistance (the AI operated a first-automated reading, and only AI-selected images were assessed by human readers). The primary endpoint was to assess the non-inferiority of AI-assisted reading versus standard reading in the detection (diagnostic yield) of potentially small bowel bleeding P1 and P2 lesions in a per-patient analysis. This study is registered with ClinicalTrials.gov, NCT04821349.From Feb 17, 2021 to Dec 29, 2021, 137 patients were prospectively enrolled. 133 patients were included in the final analysis (73 [55%] female, mean age 66·5 years [SD 14·4]; 112 [84%] completed capsule endoscopy). At per-patient analysis, the diagnostic yield of P1 and P2 lesions in AI-assisted reading (98 [73·7%] of 133 lesions) was non-inferior (p<0·0001) and superior (p=0·0213) to standard reading (82 [62·4%] of 133; 95% CI 3·6-19·0). Mean small bowel reading time was 33·7 min (SD 22·9) in standard reading and 3·8 min (3·3) in AI-assisted reading (p<0·0001).AI-assisted reading might provide more accurate and faster detection of clinically relevant small bowel bleeding lesions than standard reading.ANKON Technologies, China and AnX Robotica, USA provided the NaviCam SB system

    New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times

    No full text
    BACKGROUND: Reading capsule endoscopy (CE) is time-consuming. The Express View (EV) (IntroMedic, Seoul, Korea) software was designed to shorten CE video reading. Our primary aim was to evaluate the diagnostic accuracy of EV in detecting significant small-bowel (SB) lesions. We also compared the reading times with EV mode and standard reading (SR). METHODS: 126 patients with suspected SB bleeding and/or suspected neoplasia were prospectively enrolled and underwent SB CE (MiroCam®1200, IntroMedic, Seoul, Korea). CE evaluation was performed in standard and EV mode. In case of discrepancies between SR and EV readings, a consensus was reached after reviewing the video segments and the findings were re-classified. RESULTS: The completion rate of SB CE in our cohort was 86.5% and no retention occurred. The per-patient analysis of sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of EV compared to SR were 86%, 86%, 90%, 81%, and 86%, respectively, before consensus. After consensus, they increased to 97%, 100%, 100%, 96%, and 98%, respectively. The median reading time with SR and EV was 71 min (range 26–340) and 13 min (range 3–85), respectively (p < 0.001). CONCLUSIONS: The new-generation EV shows high diagnostic accuracy and significantly reduces CE reading times

    Indications, Detection, Completion and Retention Rates of Capsule Endoscopy in Two Decades of Use : A Systematic Review and Meta-Analysis

    Get PDF
    Background: Capsule endoscopy (CE) has become a widespread modality for non-invasive evaluation of the gastrointestinal (GI) tract, with several CE models having been developed throughout the years. The aim of this systematic review and meta-analysis is to evaluate performance measures such as completion, detection and retention rates of CE. Methods: Literature through to August 2021 was screened for articles regarding all capsule types: small bowel, double-headed capsule for the colon or PillCam® Crohn’s capsule, magnetically-controlled capsule endoscopy, esophageal capsule and patency capsule. Primary outcomes included detection rate (DR), completion rate (CR) and capsule retention rate (RR). DR, CR and RR were also analyzed in relation to indications such as obscure GI bleeding (OGIB), known/suspected Crohn’s disease (CD), celiac disease (CeD), neoplastic lesions (NL) and clinical symptoms (CS). Results: 328 original articles involving 86,930 patients who underwent CE were included. OGIB was the most common indication (n = 44,750), followed by CS (n = 17,897), CD (n = 11,299), NL (n = 4989) and CeD (n = 947). The most used capsule type was small bowel CE in 236 studies. DR, CR and RR for all indications were 59%, 89.6% and 2%, respectively. According to specific indications: DR were 55%, 66%, 63%, 52% and 62%; CR were 90.6%, 86.5%, 78.2%, 94% and 92.8%; and RR were 2%, 4%, 1%, 6% and 2%. Conclusions: Pooled DR, CR and RR are acceptable for all capsule types. OGIB is the most common indication for CE. Technological advancements have expanded the scope of CE devices in detecting GI pathology with acceptable rates for a complete examination

    Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2022.

    No full text
    MR1: ESGE recommends small-bowel capsule endoscopy as the first-line examination, before consideration of other endoscopic and radiological diagnostic tests for suspected small-bowel bleeding, given the excellent safety profile of capsule endoscopy, its patient tolerability, and its potential to visualize the entire small-bowel mucosa.Strong recommendation, moderate quality evidence. MR2: ESGE recommends small-bowel capsule endoscopy in patients with overt suspected small-bowel bleeding as soon as possible after the bleeding episode, ideally within 48 hours, to maximize the diagnostic and subsequent therapeutic yield.Strong recommendation, high quality evidence. MR3: ESGE does not recommend routine second-look endoscopy prior to small-bowel capsule endoscopy in patients with suspected small-bowel bleeding or iron-deficiency anemia.Strong recommendation, low quality evidence. MR4: ESGE recommends conservative management in those patients with suspected small-bowel bleeding and high quality negative small-bowel capsule endoscopy.Strong recommendation, moderate quality evidence. MR5: ESGE recommends device-assisted enteroscopy to confirm and possibly treat lesions identified by small-bowel capsule endoscopy.Strong recommendation, high quality evidence. MR6: ESGE recommends the performance of small-bowel capsule endoscopy as a first-line examination in patients with iron-deficiency anemia when small bowel evaluation is indicated.Strong recommendation, high quality evidence. MR7: ESGE recommends small-bowel capsule endoscopy in patients with suspected Crohn's disease and negative ileocolonoscopy findings as the initial diagnostic modality for investigating the small bowel, in the absence of obstructive symptoms or known bowel stenosis.Strong recommendation, high quality evidence. MR8: ESGE recommends, in patients with unremarkable or nondiagnostic findings from dedicated small-bowel cross-sectional imaging, small-bowel capsule endoscopy as a subsequent investigation if deemed likely to influence patient management.Strong recommendation, low quality evidence. MR9: ESGE recommends, in patients with established Crohn's disease, the use of a patency capsule before small-bowel capsule endoscopy to decrease the capsule retention rate.Strong recommendation, moderate quality evidence. MR10: ESGE recommends device-assisted enteroscopy (DAE) as an alternative to surgery for foreign bodies retained in the small bowel requiring retrieval in patients without acute intestinal obstruction.Strong recommendation, moderate quality evidence. MR11: ESGE recommends DAE-endoscopic retrograde cholangiopancreatography (DAE-ERCP) as a first-line endoscopic approach to treat pancreaticobiliary diseases in patients with surgically altered anatomy (except for Billroth II patients).Strong recommendation, moderate quality evidence
    corecore