1,040 research outputs found

    Fire toxicity - The elephant in the room?

    Get PDF
    Fire toxicity is the largest cause of death and injury from unwanted fires, yet it is the least well studied area of fire science and engineering. Fire toxicity increases by factors up to 50, as the fire becomes under-ventilated. This has proved difficult, but not impossible, to replicate in a controlled way on a bench-scale. Clear correlations have been observed between the stoichiometric equivalence ratio, and the yields of the major asphyxiants, carbon monoxide and hydrogen cyanide. In addition, irritant components of fire effluents, which have an instantaneous effect, can incapacitate fire victims, trapping them in a fire. However, the longer term toxicants present in fire effluents, such as the carcinogenic polycyclic aromatic hydrocarbons, and the microscopic particulates which result from their agglomeration are probably responsible for hundreds or thousands more deaths than the acute asphyxiants and irritants

    The influence of carbon nanotubes on the combustion toxicity of PP/intumescent flame retardant composites

    Get PDF
    In recent years, carbon nanotubes (CNTs) have emerged as a promising candidate for improving the ïŹ‚ame retardancy of polymer materials, as well as other physical properties. However, few researches have been focused on the influence of this nanoscale material on the combustion toxicity of polymer composites during combustion. In this work, the fire toxicity of polypropylene (PP) composites with intumescent flame retardants (IFRs) and CNTs has been investigated by a Purser Furnace apparatus, which is called steady state tube furnace (SSTF) and enables different ïŹre stages to be created. The Thermo gravimetric analyzer (TGA) and derivative thermo gravimetric analysis (DTG) data indicate that the thermal stability of PP composites was increased by the addition of IFRs or CNTs. However, the SSTF results show that PP samples with IFR or CNTs or both, produced much more carbon monoxide (CO) compared to neat PP during all fire stages, resulting in a much lower CO2/CO ratio. Furthermore, an interesting finding is that the effect of CNTs on the smoke production and CxHy yield of the PP samples during the combustion changes with the combustion equivalence ratio. It indicates that the presence of CNTs promote the formation of smoke particulates from hydrocarbon, but this effect only exist when oxygen supply is not adequate. It is also concluded that the air ventilation and combustion temperature play significant roles in the fire effluent production of PP samples and the morphology of soot particulates

    Benefits and Constraints of Telepsychiatry Utilization in the United States

    Get PDF
    This conference presentation describes the benefits and constraints of utilizing telemedicine primarily focusing on the field of psychiatry in the United States with the current system of healthcare. The utilization of telemedicine in the field of psychiatry is believed to provide better access, quality and care to the patients who necessitate psychiatric care in their overall medical care. Telemedicine has been a successfully integrated program into psychiatric facilities reaching rural, prisons or city facilities based on that it has increased the volume of patients in which physicians can reach out to and diagnose, as well as treat patients with limitations in his or her mobility

    Widely applicable coinage metal window electrodes on flexible polyester substrates applied to organic photovoltaics

    Get PDF
    The fabrication, exceptional properties, and application of 8 nm thick Cu, Ag, Au, and Cu/Ag bilayer electrodes on flexible polyethylene terephthalate (PET) and polyethylene naphthalate (PEN) substrates is reported. These electrodes are fabricated using a solvent free process in which the plastic surface is chemically modified with a molecular monolayer of thiol and amine terminated alkylsilanes prior to metal deposition. The resulting electrodes have a sheet resistance of ≀14 Ω sq–1, are exceptionally robust and can be rapidly thermally annealed at 200 °C to reduce their sheet resistance to ≀9 Ω sq–1. Notably, annealing Au electrodes briefly at 200 °C causes the surface to revert almost entirely to the {111} face, rendering it ideal as a model electrode for fundamental science and practical application alike. The power conversion efficiency of 1 cm2 organic photovoltaics (OPVs) employing 8 nm Ag and Au films as the hole-extracting window electrode exhibit performance comparable to those on indium–tin oxide, with the advantage that they are resistant to repeated bending through a small radius of curvature and are chemically well-defined. OPVs employing Cu and bilayer Cu:Ag electrodes exhibit inferior performance due to a lower open-circuit voltage and fill factor. Measurements of the interfacial energetics made using the Kelvin probe technique provide insight into the physical reason for this difference. The results show how coinage metal electrodes offer a viable alternative to ITO on flexible substrates for OPVs and highlight the challenges associated with the use of Cu as an electrode material in this contex

    Fire Toxicity and its Assessment

    Get PDF

    Polymers and Fire

    Get PDF

    Assessment of the fire toxicity of building insulation materials

    Get PDF
    A significant element in the cost of a new building is devoted to fire safety. Energy efficiency drives the replacement of traditional building materials with lightweight insulation materials, which, if flammable can contribute to the fire load. Most fire deaths arise from inhalation of toxic gases. The fire toxicity of six insulation materials (glass wool, stone wool, expanded polystyrene foam, phenolic foam, polyurethane foam and polyisocyanurate foam) was investigated under a range of fire conditions. Two of the materials, stone wool and glass wool failed to ignite and gave consistently low yields of all of the toxic products. The toxicities of the effluents, showing the contribution of individual toxic components, are compared using the fractional effective dose (FED) model and LC50 (the mass required per unit volume to generate a lethal atmosphere under specified conditions). For polyisocyanurate and polyurethane foam this shows a significant contribution from hydrogen cyanide resulting in doubling of the overall toxicity, as the fire condition changes from well-ventilated to under-ventilated. These materials showed an order of increasing fire toxicity, from stone wool (least toxic), glass wool, polystyrene, phenolic, polyurethane to polyisocyanurate foam (most toxic)

    Analysis of fire deaths in Poland and influence of smoke toxicity

    Get PDF
    Dwelling fires have changed over the years because building contents and the materials used in then have changed. They all contribute to an ever-growing diversity of chemical species found in fires, many of them highly toxic. These arise largely from the changing nature of materials in interior finishes and furniture, with an increasing content of synthetic materials containing higher levels of nitrogen, halogen and phosphorus additives. While there is still a belief that carbon monoxide is the major lethal toxic agent in fires, the hydrogen cyanide and acid gases released from these additives are now well-recognised as major contributory causes of incapacitation, morbidity and mortality in domestic fires. Data for the total number of 263 fire death cases in the Mazowieckie region (mainly Warsaw area) of Poland between 2003-2011 for dwellings fires were obtained from pathologists, forensic toxicologists, fire fighters and analysed. Factors contributing to the death such as the findings of the full post mortem examination (age, sex, health status, burns), the toxicological analysis (carbon monoxide, alcohol etc.), and a thorough investigation of the scene (fire conditions, fuel, etc.) were taken into account and are summarised. [Abstract copyright: Copyright © 2017 Elsevier B.V. All rights reserved.
    • 

    corecore