19 research outputs found

    Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up

    Get PDF
    Background Congenital hip dysplasia may lead to severe acetabular and femoral abnormalities that can make total hip arthroplasty a challenging procedure. We assessed a series of patients affected by developmental hip dysplasia treated with total hip arthroplasty using cementless tapered stem and here we report the outcomes at long-term follow-up. Materials and methods Twenty-eight patients (24 women and 4 men) aged between 44 and 50 years (mean 47 years) were observed. Clinical evaluation was rated with the Harris Hip Score. Radiographic evaluation consisted in standard anteroposterior and axial view radiographs of the hip. According to Crowe’s classification, 16 hips presented dysplasia grade 1, 14 grade 2, and 4 grade 3. All patients were treated with total hip arthroplasty using a cementless tapered stem (Wagner Cone Prosthesis). Six patients were operated bilaterally, with a totally of 34 hips operated. After surgery, the patients were clinically and radiographically checked at 3, 6, and 12 months and yearly thereafter until an average follow-up of 12 years (range 10–14 years). Results Average Harris Hip Score was 56 ± 9 (range 45–69) preoperatively, 90 ± 9 (range 81–100) 12 months after surgery, and 91 ± 8 (range 83–100) at last follow-up. Radiographic evaluation demonstrated excellent osteointegration of the implants. Signs of bone resorption were present in 6 hips, nevertheless no evidence of loosening was observed and none of the implants has been revised. Conclusions Even in dysplasic femur, the tapered stem allowed adequate stability and orientation of the implant. We consider tapered stem a suitable option for total hip arthroplasty in developmental hip dysplasia, also in case of young patients, thanks to the favourable long-term results

    Metacarpal Nonunion in a Two-Year-Old Child

    No full text

    The influence of the centre of rotation on implant survival using a modular stem hip prosthesis

    No full text
    The restoration of the hip centre of rotation in an anatomical position is considered to be relevant for total hip prosthesis survival. When the cup is implanted with a high centre of rotation, the lever arm of the abductor muscles is decreased, causing higher joint-reaction forces. Modular stems with varying lengths and geometries can be used to balance soft tissues, and ceramic bearing surfaces can be used to reduce the wear rate. Forty-four hip replacements performed with a high hip centre of rotation were matched with 44 performed with an anatomical centre of rotation. In all cases the preoperative diagnosis was dysplasia of the hip (DDH) and cementless modular neck prostheses with ceramic bearing surfaces were used. At nine years follow-up the mean Harris hip and WOMAC scores were not statistically different. All stems and cups were stable; the femoral offset was no different between the two groups (p = 0.4) as leg-length discrepancy (p = 0.25)

    The utility of digital templating in Total Hip Arthroplasty with Crowe type II and III dysplastic hips

    No full text
    With the superiority of digital imaging, conventional preoperative acetate templating is gradually being replaced by digital templating in total hip arthroplasty (THA). The purpose of this study was to assess the utility of digital templating for patients with Crowe type II and III dysplastic hips. In this study, 41 THA patients with Crowe type II or III dysplastic hips and 48 THA patients with other primary diseases were retrospectively reviewed. All patients were fitted with cementless prostheses in 2008. For the THA patients with dysplastic hips, we attempted to restore their hip centres to the position of the true acetabulum. Digital templating was the method chosen to achieve hip centre restoration. The prosthesis prediction accuracy (within ± one size using digital templating) was 20 (48.8%) for the cup size and 30 (73.2%) for the stem size. Meanwhile, for patients with other primary diseases, the accuracy for the cup size within ± one size was 34 (70.8%) and for the stem size accuracy was within ± one size in 38 (79.2%). Between the two patient groups, there was a significant difference in the predicted cup size. In patients with dysplastic hips, the low accuracy of the predicted cup size may have resulted from difficulty in predicting the vertical location of the hip centre. Despite this limitation, preoperative planning using digital templating is a convenient technique for THA patients with Crowe type II and III dysplastic hips
    corecore