5 research outputs found

    High performance liquid chromatography mass spectrometric method for the simultaneous quantification of pravastatin and aspirin in human plasma: Pharmacokinetic application

    Get PDF
    AbstractA rapid and sensitive liquid chromatography–tandem mass spectrometric (LC–MS/MS) assay method has been developed and fully validated for the simultaneous quantification of pravastatin and aspirin in human plasma. Furosemide was used as an internal standard. Analytes and the internal standard were extracted from human plasma by liquid–liquid extraction technique using methyl tertiary butyl ether. The reconstituted samples were chromatographed on a Zorbax SB-C18 column by using a mixture of 5mM ammonium acetate buffer and acetonitrile (20:80, v/v) as the mobile phase at a flow rate of 0.8mL/min. The calibration curve obtained was linear (r≥0.99) over the concentration range of 0.50–600.29ng/mL for pravastatin and 20.07–2012.00ng/mL for aspirin. Method validation was performed as per FDA guidelines and the results met the acceptance criteria. A run time of 2.0min for each sample made it possible to analyze more than 400 human plasma samples per day. The proposed method was found to be applicable to clinical studies

    Simultaneous determination of atorvastatin, metformin and glimepiride in human plasma by LCâMS/MS and its application to a human pharmacokinetic study

    Get PDF
    A simple, rapid and sensitive liquid chromatography-tandem mass spectrometric (LCâMS/MS) assay method has been developed and fully validated for the simultaneous quantification of atorvastatin, metformin and glimepiride in human plasma. Carbamazepine was used as internal standard (IS). The analytes were extracted from 200 μL aliquots of human plasma via protein precipitation using acetonitrile. The reconstituted samples were chromatographed on a Alltima HP C18 column by using a 60:40 (v/v) mixture of acetonitrile and 10 mM ammonium acetate (pH 3.0) as the mobile phase at a flow rate of 1.1 mL/min. The calibration curves obtained were linear (r2â¥0.99) over the concentration range of 0.50â150.03 ng/mL for atorvastatin, 12.14â1207.50 ng/mL for metformin and 4.98â494.29 ng/mL for glimepiride. The API-4000 LCâMS/MS in multiple reaction monitoring (MRM) mode was used for detection. The results of the intra- and inter-day precision and accuracy studies were well within the acceptable limits. All the analytes were found to be stable in a battery of stability studies. The method is precise and sensitive enough for its intended purpose. A run time of 2.5 min for each sample made it possible to analyze more than 300 plasma samples per day. The developed assay method was successfully applied to a pharmacokinetic study in human male volunteers. Keywords: Atorvastatin, Metformin, Glimepiride, LCâMS/MS, Human plasma, Pharmacokinetic

    Simultaneous Determination of Atorvastatin and Aspirin in Human Plasma by LC–MS/MS: Its Pharmacokinetic Application

    Get PDF
    A simple, rapid, and sensitive liquid chromatography tandem mass spectro-metric (LC–MS/MS) assay method has been developed and fully validated for the simultaneous quantification of atorvastatin and aspirin in human plasma using a polarity switch. Proguanil and furosemide were used as the internal standards for the quantification of atorvastatin and aspirin, respectively. The analytes were extracted from human plasma by the liquid–liquid extraction technique using methyl tert-butyl ether. The reconstituted samples were chromatographed on a Zorbax XDB Phenyl column by using a mixture of 0.2% acetic acid buffer, methanol, and acetonitrile (20:16:64, v/v) as the mobile phase at a flow rate of 0.8 mL/min. Prior to detection, atorvastatin and aspirin were ionized using an ESI source in the multiple reaction monitoring (MRM) mode. The ions were monitored at the positive m/z 559.2→440.0 transition for atorvastatin and the negative m/z 179.0→136.6 transition for aspirin. The calibration curve obtained was linear (r2 ≥ 0.99) over the concentration range of 0.20–151 ng/mL for atorvastatin and 15.0–3000 ng/mL for aspirin. The method validation was performed as per FDA guidelines and the results met the acceptance criteria. A run time of 3.0 min for each sample made it possible to analyze more than 300 human plasma samples per day. The proposed method was found to be applicable to clinical studies
    corecore