135 research outputs found

    Free radical scavenging and antioxidant activity of allopurinol and oxypurinol in experimental lens-induced uveitis

    Get PDF
    Purpose. In addition to the inhibition of xanthine oxidase, allopurinol is known to act, dependent on the dose, as a free radical scavenger, an antioxidant, and a "scavenger" of hypochlorous acid. This activity was investigated using a model of lens-induced uveitis. Methods. Lipid peroxides (LPO) were determined in aqueous humor and in retinal tissue. Reduced and oxidized glutathione (GSH and GSSG) of the aqueous humor and myeloperoxidase (MPO) activity in the iris-ciliary body complex were analyzed. Allopurinol and oxypurinol concentrations were determined by high-performance liquid chromatography in aqueous humor and retinal tissue of both control eyes and eyes with uveitis. These measurements were performed 6 hours after intravenous application of allopurinol. Results. In lens-induced uveitis, LPO are significantly elevated, GSH is reduced, and GSSG and MPO are increased. A xanthine oxidase inhibition dose (<10 mg/kg body weight) of allopurinol showed no effects on oxidative tissue damage in the model used in this study. Higher doses, however, were able to reduce the oxidative damage. Allopurinol (20 mg/kg body weight) had slight effects on GSH and GSSG. All parameters improved using a dose of 50 mg/kg body weight; a dose of 100 mg/kg body weight only showed additional improvement in GSH and GSSG. There was no further change in the other parameters. Allopurinol and oxypurinol concentrations in aqueous humor and retinal tissue showed a dose dependency reaching scavenger concentrations after application of 50 mg/kg body weight of allopurinol. Conclusions. These results suggest that the xanthine oxidase mechanism plays a minor role in the oxidative tissue damage due to lens-induced uveitis. Free radicals and oxidants are generated by activated leukocytes; therefore, the effect of higher doses of allopurinol is due to its free radical scavenging and antioxidative activity. Invest Ophthalmol Vis Sci. 1994; 35:3897-3904. Allopurinol is widely used in clinical medicine for the treatment of hyperuricemia. A reduction in uric acid is achieved by the inhibition of the enzyme xanthine oxidase. In ischemic diseases, xanthine oxidase uses oxygen as a reduction equivalent, leading to the formation of superoxideanion radicals. Therefore

    Comparative evaluation of diode laser versus argon laser photocoagulation in patients with central serous retinopathy: A pilot, randomized controlled trial [ISRCTN84128484]

    Get PDF
    BACKGROUND: To evaluate the efficacy of diode laser photocoagulation in patients with central serous retinopathy (CSR) and to compare it with the effects of argon green laser. METHODS: Thirty patients with type 1 unilateral CSR were enrolled and evaluated on parameters like best corrected visual acuity (BCVA), direct and indirect ophthalmoscopy, amsler grid for recording scotoma and metamorphopsia, contrast sensitivity using Cambridge low contrast gratings and fluorescein angiography to determine the site of leakage. Patients were randomly assigned into 2 groups according to the statistical random table using sequence generation. In Group 1 (n = 15), diode laser (810 nm) photocoagulation was performed at the site of leakage while in Group 2 (n = 15), eyes were treated with argon green laser (514 nm) using the same laser parameters. Patients were followed up at 4, 8 and 12 weeks after laser. RESULTS: The mean BCVA in group 1 improved from a pre-laser decimal value of 0.29 ± 0.14 to 0.84 ± 0.23 at 4 weeks and 1.06 ± 0.09 at 12 weeks following laser. In group 2, the same improved from 0.32 ± 0.16 to 0.67 ± 0.18 at 4 weeks and 0.98 ± 0.14 at 12 weeks following laser. The improvement in BCVA was significantly better in group 1 (p < 0.0001) at 4 weeks. At 4 weeks following laser, all the patients in group1 were free of scotoma while 6 patients in group 2 had residual scotoma (p < 0.05). The mean contrast sensitivity in group 1 improved from pre-laser value of 98.4 ± 24.77 to 231.33 ± 48.97 at 4 weeks and 306.00 ± 46.57 at 12 weeks following laser. In group 2, the same improved from 130.66 ± 31.95 to 190.66 ± 23.44 at 4 weeks and 215.33 ± 23.25 at 12 weeks. On comparative evaluation, a significantly better (p < 0.001) improvement was noted in group 1. CONCLUSION: Diode laser may be a better alternative to argon green laser whenever laser treatment becomes indicated in patients with central serous retinopathy in terms of faster visual rehabilitation and better contrast sensitivity. In addition, diode laser also has the well-recognized ergonomic and economic advantages

    Gewebekleber in der Netzhautchirurgie

    No full text

    Ferngesteuerte Glaskörperchirurgie

    Full text link

    Motorized Teleguided Stereotactic Micromanipulator for Vitreous Microsurgery

    No full text

    Fokale hämorrhagische Chorioretinopathie

    Full text link

    Anatomical Correlation of the Normal Fluoroangiography of the Fundus

    Full text link

    Peripheral Vascular Diseases

    Full text link
    corecore