18 research outputs found

    Intra-abdominal hypertension due to heparin - induced retroperitoneal hematoma in patients with ventricle assist devices: report of four cases and review of the literature

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Elevated intra-abdominal pressure (IAP) has been identified as a cascade of pathophysiologic changes leading in end-organ failure due to decreasing compliance of the abdomen and the development of abdomen compartment syndrome (ACS). Spontaneous retroperitoneal hematoma (SRH) is a rare clinical entity seen almost exclusively in association with anticoagulation states, coagulopathies and hemodialysis; that may cause ACS among patients in the intensive care unit (ICU) and if treated inappropriately represents a high mortality rate.</p> <p>Case Presentation</p> <p>We report four patients (a 36-year-old Caucasian female, a 59-year-old White-Asian male, a 64-year-old Caucasian female and a 61-year-old Caucasian female) that developed an intra-abdominal hypertension due to heparin-induced retroperitoneal hematomas after implantation of ventricular assist devices because of heart failure. Three of the patients presented with dyspnea at rest, fatigue, pleura effusions in chest XR and increased heart rate although b-blocker therapy. A 36-year old female (the forth patient) presented with sudden, severe shortness of breath at rest, 10 days after an "acute bronchitis". At the time of the event in all cases international normalized ratio (INR) was <3.5 and partial thromboplastin time <65 sec. The patients were treated surgically, the large hematomas were evacuated and the systemic manifestations of the syndrome were reversed.</p> <p>Conclusion</p> <p>Identifying patients in the ICU at risk for developing ACS with constant surveillance can lead to prevention. ACS is the natural progression of pressure-induced end-organ changes and develops if IAP is not recognized and treated in a timely manner. Failure to recognize and appropriately treat ACS is fatal while timely intervention - if indicated - is associated with improvements in organ function and patient survival. Means for surgical decision making are based on clinical indicators of adverse physiology, rather than on a single measured parameter.</p

    Beneficial aspects of real time flow measurements for the management of acute right ventricular heart failure following continuous flow ventricular assist device implantation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Optimal management of acute right heart failure following the implantation of a left ventricular assist device requires a reliable estimation of left ventricular preload and contractility. This is possible by real-time pump blood flow measurements.</p> <p>Clinical case</p> <p>We performed implantation of a continuous flow left ventricular assist device in a 66 years old female patient with an end-stage heart failure on the grounds of a dilated cardiomyopathy. Real-time pump blood flow was directly measured by an ultrasonic flow probe placed around the outflow graft.</p> <p>Diagnosis</p> <p>The progressive decline of real time flow and the loss of pulsatility were associated with an increase of central venous pressure, inotropic therapy and progressive renal failure suggesting the presence of an acute right heart failure. Diagnosis was validated by echocardiography and thermodilution measurements.</p> <p>Treatment</p> <p>Temporary mechanical circulatory support of the right ventricle was successfully performed. Real time flow measurement proved to be a useful tool for the diagnosis and ultimately for the management of right heart failure including the weaning from extracorporeal membrane oxygenation.</p

    Should heart failure patients be left to fate? Temporary implementation of veno-arterial extracorporeal membrane oxygenation for haemodynamic support during excision of rectal carcinoma in an end-stage biventricular heart failure patient

    No full text
    Management of end-stage heart failure patients requiring major general surgery is not well defined. Due to poor cardiorespiratory reserve, perioperative morbidity and mortality are excessively high. We report a case of temporary implementation of veno-arterial extracorporeal membrane oxygenation for haemodynamic support during excision of rectal carcinoma in an end-stage heart failure patient and describe perioperative management
    corecore