96 research outputs found

    Structure–property relationships for wet dentin adhesive polymers

    Get PDF
    Dentin adhesive systems for composite tooth restorations are composed of hydrophilic/hydrophobic monomers, solvents, and photoinitiators. The adhesives undergo phase separation and concomitant compositional change during their application in the wet oral environment; phase separation compromises the quality of the hybrid layer in the adhesive/dentin interface. In this work, the adhesive composition in the hybrid layer can be represented using the phase boundaries of a ternary phase diagram for the hydrophobic monomer/hydrophilic monomer/water system. The polymer phases, previously unaccounted for, play an important role in determining the mechanical behavior of the bulk adhesive, and the chemomechanical properties of the phases are intimately related to the effects produced by differences in the hydrophobic–hydrophilic composition. As the composition of the polymer phases varies from hydrophobic-rich to hydrophilic-rich, the amount of the adsorbed water and the nature of polymer–water interaction vary nonlinearly and strongly correlate with the change in elastic moduli under wet conditions. The failure strain, loss modulus, and glass transition temperature vary nonmonotonically with composition and are explained based upon primary and secondary transitions observed in dynamic mechanical testing. Due to the variability in composition, the assignment of mechanical properties and the choice of suitable constitutive models for polymer phases in the hybrid layer are not straightforward. This work investigates the relationship between composition and chemomechanical properties of the polymer phases formed on the wateradhesive phase boundary using quasistatic and dynamic mechanical testing, mass transfer experiments, and vibrational spectroscopy.Research Grant Nos.R01DE022054 (PI: Spencer) and R01DE025476 (Spencer/Tamerler

    Effect of initiator on photopolymerization of acidic, aqueous dental model adhesives

    Get PDF
    This study evaluated different initiator systems in self-etching model adhesives, in which camphorquinone (CQ) or [3-(3,4-dimethyl-9-oxo-9H-thioxanthen-2-yloxy)-2-hydroxylpropy] trimethylammonium chloride (QTX) was employed as a photoinitiator (dye). N-phenylglycine (NPG), ethyl 4-dimethylaminobenzoate (4E) or 2-(dimethylamino) ethyl methacrylate (DMAEMA) was used as the coinitiator (CI). The role of diphenyliodonium hexafluorophosphate (DPIHP) in the polymerization process was also studied. The concentrations of dye, CI, and DPIHP in model adhesives were all maintained at 0.022 mmol per gram monomer. The model adhesive contained two monomers: (bis[2-(methacryloyloxy)ethyl] phosphate) (2MP) and 2-hydroxyethyl methacrylate (HEMA) whose mass ratio was 1:1, thus representing an acidic and hydrophilic formulation. The polymerization rate and the degree of conversion (DC) of the model adhesives with 5, 15, or 25% water content were determined using FTIR/ATR with a time-based spectrum analysis. The results indicated that with CQ as the photoinitiator, 4E appeared to be the most efficient CI, whereas the CQ-DMAEMA combination led to very low radical generation efficiency (DC < 5%). DPIHP exhibited little effect on the polymerization process. With QTX as the photoinitiator, however, DPIHP played an essential role. Without DPIHP, all three QTX-CI systems failed to initiate polymerization (DC < 5%). The QTX-DPIHP combination, on the other hand, was found to be a viable initiator system. The above results provide the critical information for the development of self-etching adhesive systems

    Compositional design and optimization of dentin adhesive with neutralization capability

    Get PDF
    Objectives The objective of this work was to investigate the polymerization behavior, neutralization capability, and mechanical properties of dentin adhesive formulations with the addition of the tertiary amine co-monomer, 2-N-morpholinoethyl methacrylate (MEMA). Methods A co-monomer mixture based on HEMA/BisGMA (45/55, w/w) was used as a control adhesive. Compared with the control formulation, the MEMA-containing adhesive formulations were characterized comprehensively with regard to water miscibility of liquid resin, water sorption and solubility of cured polymer, real-time photopolymerization kinetics, dynamic mechanical analysis (DMA), and modulated differential scanning calorimetry (MDSC). The neutralization capacity was characterized by monitoring the pH shift of 1 mM lactic acid (LA) solution, in which the adhesive polymers were soaked. Results With increasing MEMA concentrations, experimental copolymers showed higher water sorption, lower glass transition temperature and lower crosslinking density compared to the control. The pH values of LA solution gradually increased from 3.5 to about 6.0–6.5 after 90 days. With the increase in crosslinking density of the copolymers, the neutralization rate was depressed. The optimal MEMA concentration was between 20 and 40 wt%. Conclusions As compared to the control, the results indicated that the MEMA-functionalized copolymer showed neutralization capability. The crosslinking density of the copolymer networks influenced the neutralization rate

    Scanning Acoustic Microscopy Investigation of Frequency-Dependent Reflectance of Acid-Etched Human Dentin Using Homotopic Measurements

    Get PDF
    Composite restorations in modern restorative dentistry rely on the bond formed in the adhesive-infiltrated acid-etched dentin. The physical characteristics of etched dentin are, therefore, of paramount interest. However, characterization of the acid-etched zone in its natural state is fraught with problems stemming from a variety of sources including its narrow size, the presence of water, heterogeneity, and spatial scale dependency. We have developed a novel homotopic (same location) measurement methodology utilizing scanning acoustic microscopy (SAM). Homotopic measurements with SAM overcome the problems encountered by other characterization/ imaging methods. These measurements provide us with acoustic reflectance at the same location of both the pre- and post-etched dentin in its natural state. We have applied this methodology for in vitro measurements on dentin samples. Fourier spectra from acid-etched dentin showed amplitude reduction and shifts of the central frequency that were location dependent. Through calibration, the acoustic reflectance of acid-etched dentin was found to have complex and non-monotonic frequency dependence. These data suggest that acid-etching of dentin results in a near-surface graded layer of varying thickness and property gradations. The measurement methodology described in this paper can be applied to systematically characterize mechanical properties of heterogeneous soft layers and interfaces in biological materials

    Physicochemical interactions at the dentin/adhesive interface using FTIR chemical imaging

    Get PDF
    This is the published version.To date, much of our understanding of dentin bonding has been based on investigations performed on sound, healthy dentin. This is not the substrate generally encountered in clinical practice, rather dentists must frequently bond to caries-affected dentin. Because of the extreme complexity and variability of the caries-affected dentin substrate, conventional characterization techniques do not provide adequate information for defining those factors that impact bond formation. Using Fourier-transform infrared imaging, we characterized the inhomogeneities and compositional differences across the length and breadth of the caries-affected dentin/adhesive interface. Differences in mineral/matrix ratio, crystallinity, and collagen organization were noted in the comparison of caries-affected and healthy dentin. As compared to healthy dentin, there were striking differences in depth of demineralization, adhesive infiltration, and degree of conversion at the interface with caries-affected dentin

    Determination of neutralization capacity and stability of a basic methacrylate monomer using NMR

    Get PDF
    This is an Accepted Manuscript of an article published by Taylor & Francis in International Journal of Polymeric Materials and Polymeric Biomaterials in 2012, available online: http://www.tandfonline.com/10.1080/00914037.2011.574660.The durability of dental resin depends on the stability of the polymer. The neutralizing capacity of a basic methacrylate monomer and its chemical stability were measured using nuclear magnetic resonance (NMR) spectroscopy. Lactic acid solution was titrated with 2-(dimethylamino)ethylmethacrylate (DMAEMA) or 2-hydroxyethylmethacrylate (HEMA) and its chemical shifts monitored. Addition of DMAEMA alters the chemical shift proportionally to pH neutralization, whereas HEMA has no impact. Chemical shifts were used to quantify both the change in pH and monomer stability. The results demonstrate that neutralization by basic monomer can be achieved and that this can be measured using an NMR assay

    Effect of Photo-Initiators on the In Vitro Performance of a Dentin Adhesive Exposed to Simulated Oral Environment

    Get PDF
    Our previous study showed poor mechanical durability and nano-sized heterogeneities in cross-linked dentin adhesives cured in the presence of water. To further explore the relationship between nano-scale heterogeneities and the long-term mechanical properties of dentin adhesives, the properties of model dentin adhesives polymerized using hydrophilic photoinitiators were compared with those of adhesives polymerized using hydrophobic camphorquinone-based photoinitiators. There was a continuous decline of mechanical properties for the specimens cured in the presence of water during 3 months aqueous storage, especially for the specimens that contained hydrophobic photoinitiators. The multi-component systems containing hydrophilic photoinitiators were shown to produce superior model dental adhesives when these materials are cured in the presence of water

    Tris(trimethylsilyl)silane as a co-initiator for dental adhesive: Photo-polymerization kinetics and dynamic mechanical property

    Get PDF
    Objectives The purpose of this study was to evaluate the polymerization behavior of a model dentin adhesive with tris(trimethylsilyl)silane (TTMSS) as a co-initiator, and to investigate the polymerization kinetics and mechanical properties of copolymers in dry and wet conditions. Methods A co-monomer mixture based on HEMA/BisGMA (45/55, w/w) was used as a model dentin adhesive. The photoinitiator system included camphorquinone (CQ) as the photosensitizer and the co-initiator was ethyl-4-(dimethylamino) benzoate (EDMAB) or TTMSS. Iodonium salt, diphenyliodonium hexafluorophosphate (DPIHP) serving as a catalyst, was selectively added into the adhesive formulations. The control and the experimental formulations were characterized with regard to the degree of conversion (DC) and dynamic mechanical properties under dry and wet conditions. Results In two-component photoinitiator system (CQ/TTMSS), with an increase of TTMSS concentration, the polymerization rate and DC of C═C double bond increased, and showed a dependence on the irradiation time and curing light intensity. The copolymers that contained the three-component photoinitiator system (CQ/TTMSS/DPIHP) showed similar dynamic mechanical properties, under both dry and wet conditions, to the EDMAB-containing system. Significance The DC of formulations using TTMSS as co-initiator showed a strong dependence on irradiation time. With the addition of TTMSS, the maximum polymerization rate can be adjusted and the network structure became more homogenous. The results indicated that the TTMSS could be used as a substitute for amine-type co-initiator in visible-light induced free radical polymerization of methacrylate-based dentin adhesives

    Visible-Light Initiated Free-Radical/Cationic Ring-Opening Hybrid Photopolymerization of Methacrylate/Epoxy: Polymerization Kinetics, Crosslinking Structure, and Dynamic Mechanical Properties

    Get PDF
    The effects of polymerization kinetics and chemical miscibility on the crosslinking structure and mechanical properties of polymers cured by visible-light initiated free-radical/cationic ring-opening hybrid photopolymerization are determined. A three-component initiator system is used and the monomer system contains methacrylates and epoxides. The photopolymerization kinetics is monitored in situ by Fourier transform infrared-attenuated total reflectance. The crosslinking structure is studied by modulated differential scanning calorimetry and dynamic mechanical analysis. X-ray microcomputed tomography is used to evaluate microphase separation. The mechanical properties of polymers formed by hybrid formed by free-radical polymerization. These investigations mark the first time that the benefits of the chain transfer reaction between epoxy and hydroxyl groups of methacrylate, on the crosslinking network and microphase separation during hybrid visible-light initiated photopolymerization, have been determined

    Synthesis and evaluation of novel siloxane-methacrylate monomers used as dentin adhesives

    Get PDF
    Objectives The objectives of this study were to synthesize two new siloxane-methacrylate (SM) monomers for application in dentin adhesives and to investigate the influence of different functionality of the siloxane-containing monomers on the adhesive photopolymerization, water sorption, and mechanical properties. Materials and method Two siloxane-methacrylate monomers (SM1 and SM2) with four and eight methacrylate groups were synthesized. Dentin adhesives containing BisGMA, HEMA and the siloxane-methacrylate monomers were photo-polymerized. The experimental adhesives were compared with the control adhesive (HEMA/BisGMA 45/55 w/w) and characterized with regard to degree of conversion (DC), water miscibility of the liquid resin, water sorption and dynamic mechanical analysis (DMA). Results The experimental adhesives exhibited improved water miscibility as compared to the control. When cured in the presence of 12 wt % water to simulate the wet environment of the mouth, the SM-containing adhesives showed DC comparable to the control. The experimental adhesives showed higher rubbery modulus than the control under dry conditions. Under wet conditions, the mechanical properties of the formulations containing SM monomer with increased functionality were comparable with the control, even with more water sorption. Significance The concentration and functionality of the newly synthesized siloxane-methacrylate monomers affected the water miscibility, water sorption and mechanical properties of the adhesives. The experimental adhesives show improved water compatibility compared with the control. The mechanical properties were enhanced with an increase of the functionality of the siloxane-containing monomers. The results provide critical structure/property relationships and important information for future development of durable, versatile siloxane-containing dentin adhesives
    corecore