Available low temperature thermocouple information and services
Voltage vs temperature data for thermocouple pairs at low temperatures - cryogenic temperatur
Cryogenic thermocouple calibration tables
Thermocouple calibration standards are developed for low-temperature thermocouple materials. Thermovoltage, thermopower, and the thermopower derivative are presented in tabular and graphical form
Thermal conductivity, electrical resistivity, and thermopower of aerospace alloys from 4 to 300 K. 6: Fe-22Cr-13Ni-5Mn stainless steel
The equipment and techniques for determining the thermal conductivity, electrical resistivity Lorenz ratio, and thermopower characteristics of Fe-22Cr-13Ni-5Mn stainless steel are discussed. The dimensions of the specimen and its preparation are described. The experimental data are represented by arbitrary functions over the entire range and smooth tables are generated from these functions
Thermal conductivity, electrical resistivity, and thermopower of aerospace alloys from 4 to 300 K. 3: Annealed Inconel 718
Determination of thermal conductivity, electrical resistivity, Lorentz ratio, and thermopower for annealed specimen of Inconel 718 at temperatures from 4 to 300
Thermal conductivity of austenitic stainless steel, SRM 735, from 5 to 280 K
Thermal conductivity and electrical resistivity measurements were conducted on two lots of an austenitic stainless steel. Electrical resistivity measurements were performed on the second lot, both before and after the material was hot-swaged and reannealed to a size 1/10 the original diameter. These measurements indicate that this steel can be swaged and reannealed without an appreciable change in thermal conductivity. Electrical resistivity measurements as well as direct thermal conductivity measurements on several specimens from both lots indicate a material variability in these lots of less than 1% in thermal conductivity
Standard reference materials: Thermal conductivity of electrolytic iron, SRM 734, from 4 to 300 K
Thermal conductivity data were obtained by the axial one-dimensional heat flow method for a cylindrical rod 3.6 mm in diameter and 23 cm long with an electric heater at one end and a temperature controlled sink at the other. Variability of this iron was studied by means of electrical residual resistivity ratio measurements on 63 specimens. This study showed that with a two-hour anneal at 1000 C one can obtain a thermal conductivity Standard Reference Material that has variability of less than 1% in thermal conductivity
Cryogenic thermocouple tables
Cryogenic standardized thermocouple materials table
Carbon thin film thermometry
The work concerning carbon thin film thermometry is reported. Optimum film deposition parameters were sought on an empirical basis for maximum stability of the films. One hundred films were fabricated for use at the Marshall Space Flight Center; 10 of these films were given a precise quasi-continuous calibration of temperature vs. resistance with 22 intervals between 5 and 80 K using primary platinum and germanium thermometers. Sensitivity curves were established and the remaining 90 films were given a three point calibration and fitted to the established sensitivity curves. Hydrogen gas-liquid discrimination set points are given for each film
ASRDI oxygen technology survey. Volume 4: Low temperature measurement
Information is presented on temperature measurement between the triple point and critical point of liquid oxygen. The criterion selected is that all transducers which may reasonably be employed in the liquid oxygen (LO2) temperature range are considered. The temperature range for each transducer is the appropriate full range for the particular thermometer. The discussion of each thermometer or type of thermometer includes the following information: (1) useful temperature range, (2) general and particular methods of construction and the advantages of each type, (3) specifications (accuracy, reproducibility, response time, etc.), (4) associated instrumentation, (5) calibrations and procedures, and (6) analytical representations
A ROTTERDAM APPLICATION TO INTERNATIONAL TRADE IN FRESH APPLES: A DIFFERENTIAL APPROACH
A Rotterdam import allocation model is used to fit import data for fresh apples in four importing markets important to U.S. apple exporters. Nested tests rejected homotheticity but could not reject homogeneity, symmetry, or separability among import suppliers. A Monte Carlo test rejected first-order autocorrelation in each market. Expenditure and price elasticities are calculated and reported.International Relations/Trade,
- …