    Solar Energy Engineering: Processes and Systems

    Get PDF
    Errata pdf inserted.Η βιβλιοθήκη διαθέτει αντίτυπο του βιβλίου σε έντυπη μορφή με ταξινομικό αριθμό: TJ810 .K35 2009With the threat of global warming, and the gradual depletion of petroleum supplies, solar electric power is rapidly becoming significant part of our energy mix. The range of solar cells spans different materials and different structures in the quest to extract maximum power from the device while keeping the cost to a minimum. Devices with efficiency exceeding 30% have been demonstrated in the laboratory. Solar Energy Engineering: Processes and Systems. Solar Energy Processes and Systems includes all areas of solar energy engineering. All subjects are presented from the fundamental level to the highest level of current research. The book includes subjects such as energy related environmental problems, solar collectors, solar water heating, solar space heating and cooling, industrial process heat, solar desalination, photovoltaics, solar thermal power systems and modelling of solar systems including the use of artificial intelligence systems in solar energy systems modelling and performance prediction

    A review of solar hybrid photovoltaic-thermal (PV-T) collectors and systems

    Get PDF
    In this paper, we provide a comprehensive overview of the state-of-the-art in hybrid PV-T collectors and the wider systems within which they can be implemented, and assess the worldwide energy and carbon mitigation potential of these systems. We cover both experimental and computational studies, identify opportunities for performance enhancement, pathways for collector innovation, and implications of their wider deployment at the solar-generation system level. First, we classify and review the main types of PV-T collectors, including air-based, liquid-based, dual air–water, heat-pipe, building integrated and concentrated PV-T collectors. This is followed by a presentation of performance enhancement opportunities and pathways for collector innovation. Here, we address state-of-the-art design modifications, next-generation PV cell technologies, selective coatings, spectral splitting and nanofluids. Beyond this, we address wider PV-T systems and their applications, comprising a thorough review of solar combined heat and power (S–CHP), solar cooling, solar combined cooling, heat and power (S–CCHP), solar desalination, solar drying and solar for hydrogen production systems. This includes a specific review of potential performance and cost improvements and opportunities at the solar-generation system level in thermal energy storage, control and demand-side management. Subsequently, a set of the most promising PV-T systems is assessed to analyse their carbon mitigation potential and how this technology might fit within pathways for global decarbonization. It is estimated that the REmap baseline emission curve can be reduced by more than 16% in 2030 if the uptake of solar PV-T technologies can be promoted. Finally, the review turns to a critical examination of key challenges for the adoption of PV-T technology and recommendations

    Evaluation of performance at experimental buildings and real demonstration sites in BFIRST project: Theoretical and practical aspects for BIPV monitoring system

    Get PDF
    Monitoring is one of the main activity of BFIRST, Building-integrated FIbre-Reinforced Solar Technology, project, a 5 years funded European project, project reference number 29601, that started in April 2102 and deals with the design, development and demonstration of a portfolio of innovative photovoltaic products for building integration, based on cell encapsulation within fibre-reinforced composite materials. Automatic data acquisition systems are generally required for monitoring, performance evaluation and exchanging data of PV systems. Standard IEC 61724:1998 “Photovoltaic system performance monitoring –Guidelines for measurement, data exchange and analysis” provides a guideline that shall be followed in these cases. As far as Building Integrated Photovoltaics (BIPV) are considered, besides electrical parameters there is in addition the need to monitor the specific building performances. That is because a BIPV module operates as a multi-functional building construction material; it generates energy and serves as part of the building envelope. Since the building related performances are not included in the aforementioned IEC standard, a general guideline for monitoring was prepared within the project that has been used within the project at two levels: one at experimental sites mainly related to experimental single module testing and the other at demosite with real PV size plants

    Investigation of the parameters affecting the thermosiphonic phenomenon in solar water heaters

    Get PDF
    Cyprus is currently the leading country in the world with respect to the application of solar water heaters for domestic applications, with more than 93% of the houses equipped with such a system. The great majority of these solar water heaters are of the thermosiphonic type. Thermosiphonic is a natural phenomenon where the flow of the solar heated water from the collector to the storage tank occurs from a small flow created due to the difference in density between hot and cold water. The main advantage of such systems is that they do not require a pump for circulating the water and circulation exists as long as there is sunshine. This reduces the maintenance requirements and the system is foolproof. In spite of the fact that extensive analyses of the performance of solar water heaters has been carried out by numerous researchers, almost all of them concerned forced circulation systems which use a circulating pump. Currently, the knowledge on the parameters affecting the ‘thermosiphonic phenomenon’ is rather poor while on an international level (ISO and CEN committees) there isn’t any standard to test thermosiphon solar collectors. The deeper understanding of the ‘thermosiphonic phenomenon’ and the identification of the key parameters affecting it, is the main aim of a research project currently in process in Cyprus. In this work the first preliminary results of the experimental procedure are presented. More specifically, a special test rig was set up and equipped with all sensors necessary to measure all parameters that are most likely to affect the ‘thermosiphonic phenomenon’. All tests were conducted according to ISO 9459- 2:1995(E). The system was able to operate in various weather and operating conditions and could accommodate the change of inclination of the collector. Initially, the solar collector was tested according to EN12975-2:2006 in order to determine the thermal performance at a flow and operation conditions specified by the standard. Subsequently, the efficiency of the collector operating thermosiphonically was calculated based on quasi-dynamic approach. Finally, a series of correlations were attempted using the data acquired when the collector is operating themosiphonically which are the following: (i) the temperature difference of the water at the outlet and the inlet of the collector (ΔΤ) with the solar global radiation, (ii) the water mass flow with the solar global radiation, (iii) the water mass flow with the temperature difference of the water at the outlet and the inlet of the collector (ΔΤ). The results of the data analysis showed that these parameters are very well correlated between them since the coefficient of determination (R2) is over 0.91 in all cases

    Cyprus building energy performance methodology: A comparison of the calculated and measured energy consumption results

    Get PDF
    In order to fulfil article 4 of the 2002/91/EC Directive (EPBD) a national methodology for the energy performance of buildings was drafted and approved by the Government of Cyprus in 2009. This methodology is in line with the European standards prepared to facilitate EPBD implementation and follows the asset rating approach that is, it represents the intrinsic annual energy use of a building under standardised conditions. CEN standards leave an option, quite suitable for existing and complex buildings, for operational rating, which is an energy rating based on measured amounts of delivered and exported energy. The calculated and measured rating exhibit advantages and disadvantages and as expected the results of the two approaches vary, since the measured rating approach takes into account the effect of user behaviour, the actual weather conditions and the realized (actual) thermal comfort conditions inside the building. This paper presents the Cyprus legal framework for adopting the EPBD and exhibits the Cyprus methodology for the energy performance of buildings. Moreover the advantages and disadvantages of the asset and operational rating approaches are discussed and a comparison of the results of these two approaches for a selected number of dwellings is presented. One of these cases is also examined with respect to the climatic conditions, by changing the climatic zone in which the building is erected. The latter reveals the effect of climate on the calculated energy requirements of the building for both heating and cooling

    Investigation and determination of the geothermal parameters of the ground in Cyprus for the exploitation of geothermal energy and the impact of the results in the design of the geothermal systems

    Get PDF
    The Energy Service of the Ministry of Commerce, Industry and Tourism has the overall responsibility for Energy matters in Cyprus and specifically for preparing and implementing programmes for energy conservation, the promotion of renewable energy sources (RES) and the development of technologies for the utilization of RES. The Government of Cyprus being aware of the benefits of geothermal energy and in order to increase the share of energy from renewable sources consumed in heating and cooling in 2020, promotes the geothermal energy systems through a Scheme that provides financial incentives for the utilization of RES for heating and cooling. However, the lack of valid data for the ground thermal properties in Cyprus was one of the main obstacles for the design of efficient geothermal systems, the implementation of the Schemes in the field of geothermal energy and the calculation of the share of energy from renewable sources for heating and cooling according to the methodology defined by the E.U in the directive 2009/28/EC. In an effort to identify suitable energy efficient systems for heating and cooling of buildings and the correct calculations of their contribution to the national targets, the Energy Service participated in a project founded by the Research Promotion Foundation of Cyprus to investigate and determine the geothermal parameters of the ground of Cyprus at six representative sites in Cyprus, for use in the design of ground heat exchanger applications and ground thermal storage. The paper presents the importance of the Isothermal map that helps consultants to design efficiently geothermal energy systems, calculate effectively heat losses of buildings to the ground and design the thermal energy storage equipment. The importance’s of the results are analyzed by national authorities’ experts’ point of view for evaluating geothermal applications bridging in this way the gap between technical output and commercial reality