184 research outputs found
Stacked Corrugated Horn Rings
This Brief describes a method of machining and assembly when the depth of corrugations far exceeds the width and conventional machining is not practical. The horn is divided into easily machined, individual rings with shoulders to control the depth. In this specific instance, each of the corrugations is identical in profile, and only differs in diameter and outer profile. The horn is segmented into rings that are cut with an interference fit (zero clearance with all machining errors biased toward contact). The interference faces can be cut with a reverse taper to increase the holding strength of the joint. The taper is a compromise between the interference fit and the clearance of the two faces during assembly. Each internal ring is dipped in liquid nitrogen, then nested in the previous, larger ring. The ring is rotated in the nest until the temperature of the two parts equalizes and the pieces lock together. The resulting assay is stable, strong, and has an internal finish that cannot be achieved through other methods
A Three-Frequency Feed for Millimeter-Wave Radiometry
A three-frequency millimeter-wave feed horn was developed as part of an advanced component technology task that provides components necessary for higher-frequency radiometers to meet the needs of the Surface Water and Ocean Topography (SWOT) mission. The primary objectives of SWOT are to characterize ocean sub-mesoscale processes on 10-km and larger scales in the global oceans, and to measure the global water storage in inland surface water bodies, including rivers, lakes, reservoirs, and wetlands. In this innovation, the feed provides three separate output ports in the 87-to- 97-GHz, 125-to-135-GHz, and 161-to-183- GHz bands; WR10 for the 90-GHz channel, WR8 for the 130-GHz channel, and WR5 for the 170-GHz channel. These ports are in turn connected to individual radiometer channels that will also demonstrate component technology including new PIN-diode switches and noise diodes for internal calibration integrated into each radiometer front end. For this application, a prime focus feed is required with an edge taper of approximately 20 dB at an illumination angle of 40 deg. A single polarization is provided in each band. Preliminary requirements called for a return loss of better than 15 dB, which is achieved across all three bands. Good pattern symmetry is also obtained throughout all three-frequency bands. This three-frequency broadband millimeter-wave feed also minimizes mass and provides a common focal point for all three millimeter-wave bands
High-carrier-density electron dynamics in low-temperature-grown GaAs
Pump-probe differential transmission measurements examine high-carrier-density phenomena in as-grown and annealed GaAs samples grown at temperatures from 210 to 270 °C. We observe trap saturation and Auger recombination, and accurately model the measurements on annealed samples with a simple two level rate equation, allowing us to extract the trapped-electron lifetimes. © 1997 American Institute of Physics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/70634/2/APPLAB-70-24-3245-1.pd
Dichroic Filter for Separating W-Band and Ka-Band
The proposed Aerosol/Cloud/Ecosystems (ACEs) mission development would advance cloud profiling radar from that used in CloudSat by adding a 35-GHz (Ka-band) channel to the 94-GHz (W-band) channel used in CloudSat. In order to illuminate a single antenna, and use CloudSat-like quasi-optical transmission lines, a spatial diplexer is needed to add the Ka-band channel. A dichroic filter separates Ka-band from W-band by employing advances in electrical discharge machining (EDM) and mode-matching analysis techniques developed and validated for designing dichroics for the Deep Space Network (DSN), to develop a preliminary design that both met the requirements of frequency separation and mechanical strength. First, a mechanical prototype was built using an approximately 102-micron-diameter EDM process, and tolerances of the hole dimensions, wall thickness, radius, and dichroic filter thickness measured. The prototype validated the manufacturing needed to design a dichroic filter for a higher-frequency usage than previously used in the DSN. The initial design was based on a Ka-band design, but thicker walls are required for mechanical rigidity than one obtains by simply scaling the Ka-band dichroic filter. The resulting trade of hole dimensions for mechanical rigidity (wall thickness) required electrical redesign of the hole dimensions. Updates to existing codes in the linear solver decreased the analysis time using mode-matching, enabling the electrical design to be realized quickly. This work is applicable to missions and instruments that seek to extend W-band cloud profiling measurements to other frequencies. By demonstrating a dichroic filter that passes W-band, but reflects a lower frequency, this opens up the development of instruments that both compare to and enhance CloudSat
Uro-oncology in the era of social distancing : the principles of patient-centered online consultations during the COVID-19 pandemic
The COVID-19 pandemic poses significant challenges to healthcare facilities and as per social distancing measures, many consultations are now being carried out via means of telemedicine. As some urologists may not be skilled with remote consultations, there is a need for recommendations on patient-centered online medical counseling. We have identified eight areas of excellence and defined the principles based on our experience. A professional setting should be provided, in which the privacy of the patient can be ensured. Accompanying persons should be encouraged into the consultation. Proper introduction could serve not only to verify the personality of the patient, but also to provide them with a sense of confidentiality. The interview should be held in a way to overcome the limitations of non-physical encounters, and pande-mic-specific issues should be taken into consideration. When arranging plans, the physician should judge accordingly in regards to what type of management is inevitable or safe, as well as available at this point; strict follow-up should be arranged. As home isolation may lead to unfavorable changes in lifestyle, this issue should be addressed too. The patient should be guided on how to self-educate. Concluding the visit should be aimed at proper evaluation of the patient's comprehension of the consultation. It is vital to pursue consistency in providing care to patients. While online counseling may seem challenging, if one adheres to the principles of patient-centered practice, telemedicine may become a valuable tool in maintaining the best-quality care amid the ongoing pandemic
Study of Tau-pair Production in Photon-Photon Collisions at LEP and Limits on the Anomalous Electromagnetic Moments of the Tau Lepton
Tau-pair production in the process e+e- -> e+e-tau+tau- was studied using
data collected by the DELPHI experiment at LEP2 during the years 1997 - 2000.
The corresponding integrated luminosity is 650 pb^{-1}. The values of the
cross-section obtained are found to be in agreement with QED predictions.
Limits on the anomalous magnetic and electric dipole moments of the tau lepton
are deduced.Comment: 20 pages, 9 figures, Accepted by Eur. Phys. J.
Energy dependence of Cronin momentum in saturation model for and collisions
We calculate dependence of Cronin momentum for and
collisions in saturation model. We show that this dependence is consistent with
expectation from formula which was obtained using simple dimentional
consideration. This can be used to test validity of saturation model (and
distinguish among its variants) and measure dependence of saturation
momentum from experimental data.Comment: LaTeX2e, 12 pages, 8 figure
CP asymmetry in in a general two-Higgs-doublet model with fourth-generation quarks
We discuss the time-dependent CP asymmetry of decay in an
extension of the Standard Model with both two Higgs doublets and additional
fourth-generation quarks. We show that although the Standard Model with
two-Higgs-doublet and the Standard model with fourth generation quarks alone
are not likely to largely change the effective from the decay of
, the model with both additional Higgs doublet and
fourth-generation quarks can easily account for the possible large negative
value of without conflicting with other experimental
constraints. In this model, additional large CP violating effects may arise
from the flavor changing Yukawa interactions between neutral Higgs bosons and
the heavy fourth generation down type quark, which can modify the QCD penguin
contributions. With the constraints obtained from processes
such as and , this model can lead to the
effective to be as large as in the CP asymmetry of .Comment: 13 pages, 5 figures, references added, to appear in Eur.Phys.J.
A Precise Measurement of the Tau Lifetime
The tau lepton lifetime has been measured with the e+e- -> tau+tau- events
collected by the DELPHI detector at LEP in the years 1991-1995. Three different
methods have been exploited, using both one-prong and three-prong tau decay
channels. Two measurements have been made using events in which both taus decay
to a single charged particle. Combining these measurements gave tau_tau (1
prong) = 291.8 +/- 2.3 (stat) +/- 1.5 (sys) fs. A third measurement using taus
which decayed to three charged particles yielded tau_tau (3 prong) = 288.6 +/-
2.4 (stat) +/- 1.3 (sys) fs. These were combined with previous DELPHI results
to measure the tau lifetime, using the full LEP1 data sample, to be tau_tau =
290.9 +/- 1.4 (stat) +/- 1.0 (sys) fs.Comment: 27 pages, 7 figure
- …