2,608 research outputs found

    Decomposition of a Cooling Plant for Energy Efficiency Optimization Using OptTopo

    Get PDF
    The operation of industrial supply technology is a broad field for optimization. Industrial cooling plants are often (a) composed of several components, (b) linked using network technology, (c) physically interconnected, and (d) complex regarding the effect of set-points and operating points in every entity. This leads to the possibility of overall optimization. An example containing a cooling tower, water circulations, and chillers entails a non-linear optimization problem with five dimensions. The decomposition of such a system allows the modeling of separate subsystems which can be structured according to the physical topology. An established method for energy performance indicators (EnPI) helps to formulate an optimization problem in a coherent way. The novel optimization algorithm OptTopo strives for efficient set-points by traversing a graph representation of the overall system. The advantages are (a) the ability to combine models of several types (e.g., neural networks and polynomials) and (b) an constant runtime independent from the number of operation points requested because new optimization needs just to be performed in case of plant model changes. An experimental implementation of the algorithm is validated using a simscape simulation. For a batch of five requests, OptTopo needs 61 (Formula presented.) while the solvers Cobyla, SDPEN, and COUENNE need 0.3 min, 1.4 min, and 3.1 min, respectively. OptTopo achieves an efficiency improvement similar to that of established solvers. This paper demonstrates the general feasibility of the concept and fortifies further improvements to reduce computing time

    System identification of a hysteresis-controlled pump system using SINDy

    Get PDF
    Hysteresis-controlled devices are widely used in industrial applications. For example, cooling devices usually contain a two-point controller, resulting in a nonlinear hybrid system with two discrete states. Dynamic models of systems are essential for optimizing such industrial supply technology. However, conventional system identification approaches can hardly handle hysteresis-controlled devices. Thus, the new identification method Sparse Identification of Nonlinear Dynamics (SINDy) is extended to consider hybrid systems. SINDy composes models from basis functions out of a customized library in a data-driven manner. For modeling systems that behave dependent on their own past as in the case of natural hysteresis, Ferenc Preisach introduced the relay hysteron as an elementary mathematical description. In this new method (SINDyHybrid), tailored basis functions in form of relay hysterons are added to the library which is used by SINDy. Experiments with a hysteresis controlled water basin show that this approach correctly identifies state transitions of hybrid systems and also succeeds in modeling the dynamics of the discrete system states. A novel proximity hysteron achieves the robustness of this method. The impacts of the sampling rate and the signal noise ratio of the measurement data are examined accordingly

    Signal characteristics of focal bone marrow lesions in patients with multiple myeloma using whole body T1w-TSE, T2w-STIR and diffusion-weighted imaging with background suppression

    Get PDF
    Objective: This study analyses the diagnostic potential of Diffusion-Weighted Imaging with Background Suppression (DWIBS) in the detection of focal bone marrow lesions from multiple myeloma. The signal and contrast properties of DWIBS are evaluated in correlation with the serum concentration of M-component (MC) and compared with established T1- and T2-weighted sequences. Methods: Data from 103 consecutive studies in 81 patients are analysed retrospectively. Signal intensities and apparent Diffusion Coefficients (ADC) of 79 focal lesions in the lumbar spine or pelvis of 38 patients are determined and contrast-to-noise-ratio (CNR) is calculated. Data from patients with low (20g/dL) MC are evaluated separately. Results: Signal intensities of focal myeloma lesions on T2w-STIR vary significantly depending on the MC, which leads to a loss in CNR in patients with high MC. No signal variation is observed for T1w-TSE and DWIBS. The CNR values provided by DWIBS in patients with high MC are slightly higher than those of T2w-STIR. ADC values in patients with low MC are significantly higher than in patients with high MC. Conclusion: Whole-body DWIBS has the potential to improve the conspicuity of focal myeloma lesions and provides additional biological information by ADC quantificatio

    Assessment of left atrial functional parameters using a novel dedicated analysis tool for real-time three-dimensional echocardiography: validation in comparison to magnetic resonance imaging

    Get PDF
    Real-time three-dimensional echocardiography (RT3DE) is superior to two-dimensional echocardiography in assessing left atrial (LA) parameters, but to date algorithms developed for the left ventricle were applied due to a lack of dedicated LA software. In addition, no data are available on RT3DE assessment of active atrial contraction. The aim of this study was to validate a novel RT3DE analysis tool specifically dedicated to evaluate the LA. Cardiac magnetic resonance imaging (MRI) served as standard of reference. Fifty-five patients scheduled for pulmonary vein isolation underwent cardiac MRI and RT3DE. On ultrasound image datasets, a dynamic polyhedron model of the LA was generated from which LA maximum and minimum volumes (LAmax and LAmin), passive atrial emptying fraction (LAEF), and active atrial ejection fraction (LAEFtrue) were derived and compared to values obtained from cardiac MRI. High intraclass correlations between RT3DE and MRI were found for LAmax (r=0.94, p<0.001), LAmin (r=0.95, p<0.001), LAEF (r=0.92, p<0.001), and LAEFtrue (r=0.87, p<0.001). Similarly, Bland-Altman analysis revealed narrow limits of agreement for LAmax (−28.6 to 14.1ml), LAmin (−26.8 to 12.4ml), LAEF (−11.2 to 14.9%), and LAEFtrue (−10.6 to 6.8%). LAmax, LAmin and LAEFtrue were measured significantly (p<0.05) lower by RT3DE (111±38ml vs. 118±39ml, 73±38ml vs. 80±41ml, and 23±14% vs. 27±14%, respectively). Interobserver and intraobserver RT3DE measurements correlated closely. RT3DE using a novel dedicated software tool is valid, accurate and reproducible for assessing LA dimensional and functional parameters. This study corroborates previous reports and extends its validity to the assessment of active LA contractio

    Preoperative staging of non-small-cell lung cancer: comparison of whole-body diffusion-weighted magnetic resonance imaging and 18F-fluorodeoxyglucose-positron emission tomography/computed tomography

    Get PDF
    Objective: To investigate the diagnostic value of whole-body magnetic resonance imaging (MRI) including diffusion-weighted imaging with background signal suppression (DWIBS) for preoperative assessment of non-small-cell lung cancer (NSCLC) in comparison to 18F-fluorodeoxyglucose 18FDG) positron emission tomography/computed tomography (PET/CT). Methods: Thirty-three patients with suspected NSCLC were enrolled. Patients were examined before surgery with PET/CT and whole-body MRI including T1-weighted turbo spin echo (TSE), T2-weighted short tau inversion recovery (STIR) and DWIBS sequences (b = 0/800). Histological or cytological specimens were taken as standard of reference. Results: Whole-body MRI with DWIBS as well as PET/CT provided diagnostic image quality in all cases. Sensitivity for primary tumour detection: MRI 93%, PET/CT 98%. T-staging accuracy: MRI 63%, PET/CT 56%. N-staging accuracy: MRI 66%, PET/CT 71%. UICC staging accuracy: MRI 66%, PET/CT 74%. Sensitivity for metastatic involvement of individual lymph node groups: MRI 44%, PET/CT 47%. Specificity for individual non-metastatic lymph node groups: MRI 93%, PET/CT 96%. Assessment accuracy for individual lymph node groups: MRI 85%, PET/CT 88%. Observer agreement rate for UICC staging: MRI 74%, PET/CT 90%. Conclusion: Whole-body MRI with DWIBS provides comparable results to PET/CT in staging of NSCLC, but shows no superiority. Most relevant challenges for both techniques are T-staging accuracy and sensitivity for metastatic lymph node involvement. Key Points : • Numerous radiological methods are available for the crucial staging of lung cancer • Whole-body DWIBS MRI provides comparable results to PET/CT in NSCLC staging. • No evident superiority of whole-body DWIBS over PET/CT in NSCLC staging. • Challenges for both techniques are T-staging and detection of small metastase

    Surfactant function in lung transplantation after 24 hours of ischemia: Advantage of retrograde flush perfusion for preservation

    Get PDF
    AbstractObjective: Surfactant function was shown to be impaired in clinical and experimental lung transplantation. This study was designed to define the impact of retrograde flush perfusion on graft and surfactant function after an extended period of ischemia. Methods: Left lung transplantation was performed after 24 hours of graft ischemia in 12 pigs. In half of the grafts antegrade cold flush perfusion (Perfadex) was used for preservation. In the second group grafts were flushed in a retrograde fashion via the left atrium. Graft function was monitored for 7 hours after transplantation. Before transplantation (basal) and after 2 hours of reperfusion, bronchoalveolar lavage fluid was obtained. Minimal surface tension of bronchoalveolar lavage fluid was determined and the ratio of small and large surfactant aggregates was calculated. Lung water content was analyzed online in the reperfusion period. Results: Right-sided heart failure developed in 2 animals of group 1 (antegrade perfusion) within 2 and 4.5 hours of reperfusion, respectively. All other pigs survived the observation period. PO2/FIO2 (P =.001) and dynamic lung compliance (P =.001) were superior in retrogradely flushed grafts. A comparable increase of minimal surface tension was found after reperfusion in both groups. Small/large surfactant aggregate ratio after reperfusion (P =.03), as well as extravascular lung water content, was higher in the antegrade perfusion group. Conclusion: Retrograde flush perfusion for 24-hour lung preservation with low-potassium dextran (Perfadex) solution led to better initial graft function than the standard antegrade perfusion technique. A moderate impairment of surfactant function was found in both groups, which was more pronounced in the antegrade perfusion group

    Primary intrathoracic malignant mesenchymal tumours: computed tomography features of a rare group of chest neoplasms

    Get PDF
    OBJECTIVES: To describe the computed tomography (CT) features in a case series of primary intrathoracic extracardiac malignant mesenchymal tumours (sarcomas). METHODS: A 5-year retrospective research was conducted, and 18 patients were selected. CT exams were reviewed by two chest radiologists, blinded to tumour pathological type, origin and grade. Lesions were described in relation to location, size, shape, margins, enhancement, presence of cavitation, calcifications, ground glass component, intratumoural enhanced vessels, pleural effusion, pleural tags, lymphangitis, chest wall/rib involvement and pathological lymph nodes. RESULTS: The readers described five pulmonary, six mediastinal and seven pleural/wall based lesions. Mean largest diameter was 103 mm. The most frequent shape was irregular (n = 12), most predominant margin was smooth (n = 12) and enhancement was mostly heterogeneous (n = 8). Intratumoural vessels and pleural effusion were seen in 11 patients. Pathological lymph nodes were present in four cases and calcifications in two cases. CONCLUSIONS: Some frequent radiological features were described independently of tumour location and subtype. A sarcoma should be included as a major differential diagnosis when the radiologist faces an intrathoracic mass of large size (>70 mm) but with well defined smooth or lobulated margins, especially if presenting intratumoural vessels, associated pleural effusion but no significant lymphadenopathy. MAIN MESSAGES: • Malignant mesenchymal tumours (sarcomas) are rare and can arise from any structure in the chest. • Intrathoracic sarcomas show some frequent radiological features, independent of location and type. • Some CT features may help the radiologist suspect for a sarcoma instead of other more common tumours

    ERAD Components in Organisms with Complex Red Plastids Suggest Recruitment of a Preexisting Protein Transport Pathway for the Periplastid Membrane

    Get PDF
    The plastids of cryptophytes, haptophytes, and heterokontophytes (stramenopiles) (together once known as chromists) are surrounded by four membranes, reflecting the origin of these plastids through secondary endosymbiosis. They share this trait with apicomplexans, which are alveolates, the plastids of which have been suggested to stem from the same secondary symbiotic event and therefore form a phylogenetic clade, the chromalveolates. The chromists are quantitatively the most important eukaryotic contributors to primary production in marine ecosystems. The mechanisms of protein import across their four plastid membranes are still poorly understood. Components of an endoplasmic reticulum-associated degradation (ERAD) machinery in cryptophytes, partially encoded by the reduced genome of the secondary symbiont (the nucleomorph), are implicated in protein transport across the second outermost plastid membrane. Here, we show that the haptophyte Emiliania huxleyi, like cryptophytes, stramenopiles, and apicomplexans, possesses a nuclear-encoded symbiont-specific ERAD machinery (SELMA, symbiont-specific ERAD-like machinery) in addition to the host ERAD system, with targeting signals that are able to direct green fluorescent protein or yellow fluorescent protein to the predicted cellular localization in transformed cells of the stramenopile Phaeodactylum tricornutum. Phylogenies of the duplicated ERAD factors reveal that all SELMA components trace back to a red algal origin. In contrast, the host copies of cryptophytes and haptophytes associate with the green lineage to the exclusion of stramenopiles and alveolates. Although all chromalveolates with four membrane-bound plastids possess the SELMA system, this has apparently not arisen in a single endosymbiotic event. Thus, our data do not support the chromalveolate hypothesis
    • …
    corecore