592 research outputs found

    Development of liquid xenon detectors for medical imaging

    Full text link
    In the present paper, we report on our developments of liquid xenon detectors for medical imaging, positron emission tomography and single photon imaging, in particular. The results of the studies of several photon detectors (photomultiplier tubes and large area avalanche photodiode) suitable for detection of xenon scintillation are also briefly described.Comment: 13 pages, 5 figures, presented on the International Workshop on Techniques and Applications of Xenon Detectors (Xenon01), ICRR, Univ. of Tokyo, Kashiwa, Japan, December 3-4, 2001 (submitted to proceedings

    A model of the reflection distribution in the vacuum ultra violet region

    Full text link
    A reflection model with three components, a specular spike, a specular lobe and a diffuse lobe is discussed. This model was successfully applied to describe reflection of xenon scintillation light (175 nm) by PTFE and other fluoropolymers and can be used for Monte Carlo simulation and analysis of scintillation detectors. The measured data favors a Trowbridge-Reitz distribution function of ellipsoidal micro-surfaces. The intensity of the coherent reflection increases with increasing angle of incidence, as expected, since the surface appears smoother at grazing angles. The total reflectance obtained for PTFE is about 70% for VUV light at normal incidence in vacuum and estimated to be up to 100% in contact with liquid xenon

    Reflectance of Polytetrafluoroethylene (PTFE) for Xenon Scintillation Light

    Full text link
    Gaseous and liquid xenon particle detectors are being used in a number of applications including dark matter search and neutrino-less double beta decay experiments. Polytetrafluoroethylene (PTFE) is often used in these detectors both as electrical insulator and as a light reflector to improve the efficiency of detection of scintillation photons. However, xenon emits in the vacuum ultraviolet wavelength region (175 nm) where the reflecting properties of PTFE are not sufficiently known. In this work we report on measurements of PTFE reflectance, including its angular distribution, for the xenon scintillation light. Various samples of PTFE, manufactured by different processes (extruded, expanded, skived and pressed) have been studied. The data were interpreted with a physical model comprising both specular and diffuse reflections. The reflectance obtained for these samples ranges from about 47% to 66% for VUV light. Fluoropolymers, namely ETFE, FEP and PFA were also measured

    GEM operation in double-phase xenon

    Get PDF
    http://www.sciencedirect.com/science/article/B6TJM-4T7F5JF-5/2/897502f8049abd8c2dd3dffc3821f0f

    Scintillation efficiency of liquid xenon for nuclear recoils with the energy down to 5 keV

    Full text link
    The scintillation efficiency of liquid xenon for nuclear recoils has been measured to be nearly constant in the recoil energy range from 140 keV down to 5 keV. The average ratio of the efficiency for recoils to that for gamma-rays is found to be 0.19+-0.02.Comment: 13 pages, 5 figure

    Low Temperature Performance of a Large Area Avalanche Photodiode

    Get PDF
    A Large Area Avalanche Photodiode (LAAPD) was studied, aiming to access its performance as light detector at low temperatures, down to -80 C. The excess noise factor, F, was measured and found to be approximately independent of the temperature. A linear dependence of F on the APD gain with a slope of 0.00239 +/- 0.00008 was observed for gains above 100. The detection of low intensity light pulses, producing only a few primary electron-hole pairs in the photodiode, is reported.Comment: 16 pages, 7 figures; was presented at 3-rd conference "New Developments in Photodetection" Beaune, France, June 17-21, 2002; submitted to NI
    corecore