67 research outputs found

    Feasibility of MV CBCT-based treatment planning for urgent radiation therapy: dosimetric accuracy of MV CBCT-based dose calculations.

    Get PDF
    Unlike scheduled radiotherapy treatments, treatment planning time and resources are limited for emergency treatments. Consequently, plans are often simple 2D image-based treatments that lag behind technical capabilities available for nonurgent radiotherapy. We have developed a novel integrated urgent workflow that uses onboard MV CBCT imaging for patient simulation to improve planning accuracy and reduce the total time for urgent treatments. This study evaluates both MV CBCT dose planning accuracy and novel urgent workflow feasibility for a variety of anatomic sites. We sought to limit local mean dose differences to less than 5% compared to conventional CT simulation. To improve dose calculation accuracy, we created separate Hounsfield unit-to-density calibration curves for regular and extended field-of-view (FOV) MV CBCTs. We evaluated dose calculation accuracy on phantoms and four clinical anatomical sites (brain, thorax/spine, pelvis, and extremities). Plans were created for each case and dose was calculated on both the CT and MV CBCT. All steps (simulation, planning, setup verification, QA, and dose delivery) were performed in one 30 min session using phantoms. The monitor units (MU) for each plan were compared and dose distribution agreement was evaluated using mean dose difference over the entire volume and gamma index on the central 2D axial plane. All whole-brain dose distributions gave gamma passing rates higher than 95% for 2%/2 mm criteria, and pelvic sites ranged between 90% and 98% for 3%/3 mm criteria. However, thoracic spine treatments produced gamma passing rates as low as 47% for 3%/3 mm criteria. Our novel MV CBCT-based dose planning and delivery approach was feasible and time-efficient for the majority of cases. Limited MV CBCT FOV precluded workflow use for pelvic sites of larger patients and resulted in image clearance issues when tumor position was far off midline. The agreement of calculated MU on CT and MV CBCT was acceptable for all treatment sites

    Assessment of image quality and dose calculation accuracy on kV CBCT, MV CBCT, and MV CT images for urgent palliative radiotherapy treatments.

    Get PDF
    A clinical workflow was developed for urgent palliative radiotherapy treatments that integrates patient simulation, planning, quality assurance, and treatment in one 30-minute session. This has been successfully tested and implemented clinically on a linac with MV CBCT capabilities. To make this approach available to all clinics equipped with common imaging systems, dose calculation accuracy based on treatment sites was assessed for other imaging units. We evaluated the feasibility of palliative treatment planning using on-board imaging with respect to image quality and technical challenges. The purpose was to test multiple systems using their commercial setup, disregarding any additional in-house development. kV CT, kV CBCT, MV CBCT, and MV CT images of water and anthropomorphic phantoms were acquired on five different imaging units (Philips MX8000 CT Scanner, and Varian TrueBeam, Elekta VersaHD, Siemens Artiste, and Accuray Tomotherapy linacs). Image quality (noise, contrast, uniformity, spatial resolution) was evaluated and compared across all machines. Using individual image value to density calibrations, dose calculation accuracies for simple treatment plans were assessed for the same phantom images. Finally, image artifacts on clinical patient images were evaluated and compared among the machines. Image contrast to visualize bony anatomy was sufficient on all machines. Despite a high noise level and low contrast, MV CT images provided the most accurate treatment plans relative to kV CT-based planning. Spatial resolution was poorest for MV CBCT, but did not limit the visualization of small anatomical structures. A comparison of treatment plans showed that monitor units calculated based on a prescription point were within 5% difference relative to kV CT-based plans for all machines and all studied treatment sites (brain, neck, and pelvis). Local dose differences >5% were found near the phantom edges. The gamma index for 3%/3 mm criteria was ≥95% in most cases. Best dose calculation results were obtained when the treatment isocenter was near the image isocenter for all machines. A large field of view and immediate image export to the treatment planning system were essential for a smooth workflow and were not provided on all devices. Based on this phantom study, image quality of the studied kV CBCT, MV CBCT, and MV CT on-board imaging devices was sufficient for treatment planning in all tested cases. Treatment plans provided dose calculation accuracies within an acceptable range for simple, urgently planned palliative treatments. However, dose calculation accuracy was compromised towards the edges of an image. Feasibility for clinical implementation should be assessed separately and may be complicated by machine specific features. Image artifacts in patient images and the effect on dose calculation accuracy should be assessed in a separate, machine-specific study. PACS number(s): 87.55.D-, 87.57.C-, 87.57.Q

    Targeted Gene Expression Profiling Predicts Meningioma Outcomes and Radiotherapy Responses

    Get PDF
    Surgery is the mainstay of treatment for meningioma, the most common primary intracranial tumor, but improvements in meningioma risk stratification are needed and indications for postoperative radiotherapy are controversial. Here we develop a targeted gene expression biomarker that predicts meningioma outcomes and radiotherapy responses. Using a discovery cohort of 173 meningiomas, we developed a 34-gene expression risk score and performed clinical and analytical validation of this biomarker on independent meningiomas from 12 institutions across 3 continents (N = 1,856), including 103 meningiomas from a prospective clinical trial. The gene expression biomarker improved discrimination of outcomes compared with all other systems tested (N = 9) in the clinical validation cohort for local recurrence (5-year area under the curve (AUC) 0.81) and overall survival (5-year AUC 0.80). The increase in AUC compared with the standard of care, World Health Organization 2021 grade, was 0.11 for local recurrence (95% confidence interval 0.07 to 0.17, P \u3c 0.001). The gene expression biomarker identified meningiomas benefiting from postoperative radiotherapy (hazard ratio 0.54, 95% confidence interval 0.37 to 0.78, P = 0.0001) and suggested postoperative management could be refined for 29.8% of patients. In sum, our results identify a targeted gene expression biomarker that improves discrimination of meningioma outcomes, including prediction of postoperative radiotherapy responses

    Direct and indirect costs associated with stereotactic radiosurgery or open surgery for medial temporal lobe epilepsy: Results from the ROSE trial

    Get PDF
    Objective To determine whether a less-invasive approach to surgery for medically refractory temporal lobe epilepsy is associated with lower health care costs and costs of lost productivity over time, compared to open surgery. Methods We compared direct medical costs and indirect productivity costs associated with treatment with stereotactic radiosurgery (SRS) or anterior temporal lobectomy (ATL) in the ROSE (Radiosurgery or Open Surgery for Epilepsy) trial. Health care use was abstracted from hospital bills, the study database, and diaries in which participants recorded health care use and time lost from work while seeking care. Costs of use were calculated using a Medicare costing approach used in a prior study of the costs of ATL. The power of many analyses was limited by the sample size and data skewing. Results Combined treatment and follow-up costs (in thousands of US dollars) did not differ between SRS (n = 20, mean = 76.6,9576.6, 95% confidence interval [CI] = 50.7-115.6) and ATL (n = 18, mean = 79.0, 95% CI = 60.09-103.8). Indirect costs also did not differ. More ATL than SRS participants were free of consciousness-impairing seizures in each year of follow-up (all P < 0.05). Costs declined following ATL (P = 0.005). Costs tended to increase over the first 18 months following SRS (P = 0.17) and declined thereafter (P = 0.06). This mostly reflected hospitalizations for SRS-related adverse events in the second year of follow-up. Significance Lower initial costs of SRS for medial temporal lobe epilepsy were largely offset by hospitalization costs related to adverse events later in the course of follow-up. Future studies of less-invasive alternatives to ATL will need to assess adverse events and major costs systematically and prospectively to understand the economic implications of adopting these technologies

    Efaproxiral: Should We Hold Our Breath?

    No full text

    Damage to the Superior Retinae After 30 Gy Whole-Brain Radiation.

    No full text
    PurposeThe most common treatment protocol for whole-brain radiation therapy (WBRT) is 30 Gy in 10 fractions. This regimen entails a low risk of radiation retinopathy, with fewer than a dozen reported cases. We describe a case of radiation retinopathy that was confined to the superior retinae. These regions were the only portions of the eyes that were included in the treatment field.Methods and materialsObservational case report consisting of clinical examination, review of radiation treatment planning and implementation, computerized visual field testing, and fundus photography.ResultsA 36-year-old man with metastatic lung adenocarcinoma developed radiation retinopathy 16 months after WBRT to 30 Gy in 10 fractions. The retinopathy was largely confined to the superior halves of the retinae. There was corresponding geographic inferior visual field loss in both eyes. Review of the patient's treatment protocol revealed that the superior retinae received a substantial radiation dose, approaching 30 Gy, whereas the inferior retinae were essentially outside the treatment field.ConclusionsIn this patient, the correlation between the treatment field and the resulting local development of radiation retinopathy demonstrated unequivocally that the relatively low dose used in routine WBRT (ie, 30 Gy in 10 fractions) can induce radiation retinopathy

    Recurrent Radiation-Induced Cavernous Malformation After Gamma Knife Stereotactic Radiosurgery for Brain Metastasis.

    No full text
    Cavernous malformations are a rare complication of radiation therapy reported most commonly as a late complication after cranial irradiation for pediatric malignancies. However, cavernous malformations after stereotactic radiosurgery in adult patients are not well characterized. We present a case of a 67-year-old female with metastatic breast cancer who received Gamma Knife stereotactic radiosurgery for brain metastases and developed a cavernous malformation at the site of a treated metastasis 30 months after treatment. She underwent resection and did well until 55 months later, when she developed symptomatic recurrence of cavernous malformation without evidence of tumor recurrence, requiring repeat resection. This represents the first reported case of radiation-induced cavernous malformation treated with stereotactic radiosurgery for brain metastases, who later developed a recurrence of the cavernous malformation. As patients with brain metastases are living longer and are increasingly treated with stereotactic radiosurgery, awareness of cavernous malformation as a potential complication and the risk of recurrence is critical to ensure appropriate diagnosis and management

    Angiographic features help predict outcome after stereotactic radiosurgery for the treatment of pediatric arteriovenous malformations.

    No full text
    PurposeArteriovenous malformations (AVMs) are a frequent cause of hemorrhagic stroke in children. Stereotactic radiosurgery (SRS) is an established treatment for these lesions, particularly those that are surgically inaccessible. Because only complete AVM obliteration is believed to protect against the future risk of hemorrhage, identifying lesion characteristics that predict response to therapy is an important objective. The goal of this study is to evaluate the influence of angiographic features of AVMs on the rate of obliteration following treatment with SRS.MethodsThis is a retrospective cohort study of pediatric patients (age ≤18 years) treated with Gamma Knife SRS for cerebral AVMs between 2000 and 2012. Detailed angiographic data at the time of initial angiographic evaluation were prospectively recorded by experienced neurointerventional radiologists. The primary outcome was the rate of obliteration on a 3-year follow-up angiogram.ResultsWe identified 42 pediatric patients treated with SRS for cerebral AVMs. Twenty-seven patients completed 3-year angiographic follow-ups. Complete obliteration was seen in 30%, partial response in 67%, and no response in 4%. Higher SRS dose was associated with complete obliteration. Larger AVM diameter, presence of multiple draining veins, and presence of multiple draining veins reaching a sinus were associated with partial response. In this small cohort, diffuse AVM borders, presence of aneurysm, and pre-SRS embolization were not associated with obliteration.ConclusionsOur study identifies AVMs in the pediatric population with a nidus diameter of &lt;2.5 cm and a solitary draining vein as the most likely to undergo complete obliteration after SRS treatment
    • …