61 research outputs found
Stress Reduction Using Bilateral Stimulation in Virtual Reality
The goal of this research is to integrate Virtual Reality (VR) with the bilateral stimulation used in EMDR as a tool to relieve stress. We created a 15 minutes relaxation training program for adults in a virtual, relaxing environment in form of a walk in the woods. The target platform for the tool is HTC Vive, however it can be easily ported to other VR platforms. An integral part of this tool is a set of sensors, which serves as physiological measures to evaluate the effectiveness of such system. What is more, the system integrate visual (passing sphere), auditory (surround sound) and tactile signals (vibration of controllers). A pilot treatment programme, incorporating the above mentioned VR system, was carried out. Experimental group consisting of 28 healthy adult volunteers (office workers), participated in three different sessions of relaxation training. Before starting, baseline features such as subjectively perceived stress, mood, heart rate, galvanic skin response and muscle response were registered. The monitoring of physiological indicators is continued during the training session and one minute after its completion. Before and after the session, volunteers were asked to re-fill questionnaires regarding the current stress level and mood. The obtained results were analyzed in terms of variability over time: before, during and after the session
The co-application of hypoxic preconditioning and postconditioning abolishes their own protective effect on systolic function in human myocardium
Background: Ischemic preconditioning (IPC) and postconditioning (POC) are well documented to trigger cardioprotection against ischemia/reperfusion (I/R) injury, but the effect oftheir both co-application remains unclear in human heart. The present study sought to assessthe co-application of IPC and POC on fragments of human myocardium in vitro.Methods: Muscular trabeculae of the human right atrial were electrically driven in the organbath and subjected to simulated I/R injury – hypoxia/re-oxygenation injury in vitro. To achieveIPC of trabeculae the single brief hypoxia period preceded the applied lethal hypoxia, and to achieve POC triple brief hypoxia periods followed the lethal hypoxia. Additional muscular trabeculae were exposed only to the hypoxic stimulation (Control) or were subjected to the non-hypoxic stimulation (Sham). 10 μM norepinephrine (NE) application ended every experiment to assess viability of trabeculae. The contraction force of the myocardium assessed as a maximal amplitude of systolic peak (%Amax) was obtained during the whole experiment’s period.Results: Co-application of IPC and POC resulted in decrease in %Amax during the re-oxygentaionperiod and after NE application, as compared to Control (30.35 ± 2.25 vs. 41.89 ± 2.25, 56.26 ± 7.73 vs. 65.98 ± 5.39, respectively). This was in contrary to the effects observed when IPC and POC were applied separately.Conclusions: The co-application of IPC and POC abolishes the cardioprotection of either intervention alone against simulated I/R injury in fragments of the human right heart atria
Heat Transfer Process Within The R744 Two-phase Ejector: Numerical And Experimental Study
The proposed three dimensional CFD model to simulate the influence of the heat transfer on the R744 two-phase ejector performance is presented. The numerical model was developed based on the homogeneous real fluid flow assumption with the enthalpy-based formulation of the energy equation. The R744 two-phase ejector was designed to evaluate the temperature profile within the ejector walls. The prototype R744 ejector for experimental investigation was manufactured by Institute of Thermal Technology and ATM in Poland. The performance measurements were carried out at a R744 test facility at SINTEF/NTNU in Norway. The foregoing ejector was equipped with the thirteen thermocouples located inside the ejector to measure the wall temperature in different ejector section i.e. the motive nozzle, the suction nozzle, the mixing section and the diffuser. The experimental test campaign at different operating conditions typical for refrigeration application was carried out and the uncertainty of the measurement was defined. Moreover, the experimental data are applied to validate the CFD results at defined operating conditions. The numerical results were set to evaluate the influence of the wall temperature on the two-phase flow parameters. In addition, the heat transfer coefficient of the two-phase flow within the ejector was estimated. The analysis of the heat transfer process within the R744 two-phase ejector let to investigate the influence of the ambient conditions and the different temperature levels of the motive and suction streams on the ejector performance
Thermal analysis of 8.5 MVA disk-type power transformer cooled by biodegradable ester oil working in ONAN mode by using advanced EMAG–CFD–CFD coupling
Power transformers are the first devices used to transfer the electrical energy produced in power plants to the grid to supply the industrial and individual receivers with electricity. The heat generation in windings and core, being an effect of the power losses, is usually dissipated in large units by using mineral oils, which are harmful to the environment. Nowadays, the industry and global society seek environmentally-friendly alternatives. One of the most promising substitute for their high biodegradability, safety in operation, and favourable thermo-physical properties are natural ester oils. For this reason, a numerical study of 8.5 MVA disk-type power transformer cooled using conventional mineral oil and a commercially used rapeseed ester oil is presented in this paper. Moreover, due to different thermal behaviour of the considered oils, the comparison was made for the unit working in different seasons of hot and moderate climate zones (Argentina and Poland). In the numerical approach, electromagnetic (EMAG) and computational fluid dynamics (CFD) models were used for a detailed study of the selected device. In particular, a novel and very efficient EMAG–CFD–CFD coupling procedure was developed to assess the cooling of the large power transformer. Such a coupled computational procedure allowed for the detailed investigation of the power loss, oil flow characteristics, and temperatures with a satisfying computational effort. The results showed that the average windings temperatures are higher by 2–9 K when the ester oil is used, dependent on the ambient conditions. The hotspot temperature in the low voltage windings increased by up to 9 K and up to 18 K in the high voltage windings using ester oil. According to the results, the oil duct construction requires modification in the high voltage region for transformers cooled using mineral oil in cold climate conditions.Fil: Stebel, Michal. Silesian University Of Technology; PoloniaFil: Kubiczek, Krzysztof. Silesian University Of Technology; PoloniaFil: Rios Rodriguez, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; ArgentinaFil: Palacz, Michal. Silesian University Of Technology; PoloniaFil: Garelli, Luciano. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; ArgentinaFil: Melka, Bartlomiej. Silesian University Of Technology; PoloniaFil: Haida, Michal. Silesian University Of Technology; PoloniaFil: Bodys, Jakub. Silesian University Of Technology; PoloniaFil: Nowak, Andrzej J.. Silesian University Of Technology; PoloniaFil: Lasek, Pawel. Silesian University Of Technology; PoloniaFil: Stepien, Mariusz. Silesian University Of Technology; PoloniaFil: Pessolani, Francisco. Tadeo Czerweny S.a.; ArgentinaFil: Amadei, Mauro. Tadeo Czerweny S.a.; ArgentinaFil: Granata, Daniel. Tadeo Czerweny S.a.; ArgentinaFil: Storti, Mario Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; ArgentinaFil: Smolka, Jacek. Silesian University Of Technology; Poloni
Development of the natural working fluid‐based refrigeration system for domestic scale freeze‐dryer
In this work, the analysis of the refrigeration system designed for the FrostX 10 freeze‐dryer is presented. The main goal of this study was to experimentally investigate the reference R452a freeze‐dryer and prepare recommendations for a machine based on the R290 refrigeration unit. In order to guarantee the temperature requirements and efficient operation of that unit, the analysis of suitable natural refrigerants was performed. Consequently, propane (R290) was selected. In addition, a number of modifications were introduced for the prototype system. System analysis showed that the replacement of the refrigerant in the existing system improves the system energy efficiency by approximately 18%. During the experimental campaign of the basic refrigeration unit, an unstable operation of the evaporator was found. The concept of a new cooling system for a prototype device was presented. The configuration and type of heat exchanger to maximise the performance of the ice trap of the freeze‐dryer were proposed.Development of the natural working fluid‐based refrigeration system for domestic scale freeze‐dryeracceptedVersio
Effects of trans-endocardial delivery of bone marrow-derived CD133+ cells on angina and quality of life in patients with refractory angina: A sub-analysis of the REGENT-VSEL trial
Background: The REGENT-VSEL trial demonstrated a neutral effect of transendocardial injection of autologous bone marrow (BM)-derived CD133+ in regard to myocardial ischemia. The current sub-analysis of the REGENT VSEL trial aims to assess the effect stem cell therapy has on quality of life (QoL) in patients with refractory angina.Methods: Thirty-one patients (63.0 ± 6.4 years, 70% male) with recurrent CCS II–IV angina, despite optimal medical therapy, enrolled in the REGENT-VSEL single center, randomized, double-blinded, and placebo-controlled trial. Of the 31 patients, 16 individuals were randomly assigned to the active stem cell group and 15 individuals were randomly assigned to the placebo group on a 1:1 basis. The inducibility of ischemia, (≥ one myocardial segment) was confirmed for each patient using Tc-99m SPECT. QoL was measured using the Seattle Angina Questionnaire. Each patient completed the questionnaire prior to treatment and at the time of their outpatient follow-up visits at 1, 4, 6, and 12 months after cell/placebo treatment.Results: The main finding of the REGENT-VSEL trial sub-analysis was that transendocardial injection of autologous BM-derived CD133+ stem cells in patients with chronic refractory angina did not show significant improvement in QoL in comparison to the control group. Moreover, there was no significant difference between cell therapy and placebo in a number of patients showing improvement of at least 1 Canadian Cardiovascular Society class during the follow-up period.Conclusions: Intra-myocardial delivery of autologous CD133+ stem cells is safe and feasible but does not show a significant improvement in the QoL or angina pectoris symptoms in patients with chronic myocardial ischemia
Przezcewnikowa implantacja zastawki aortalnej w leczeniu dysfunkcyjnych bioprotez chirurgicznych i przezcewnikowych. Opinia ekspertów Asocjacji Interwencji Sercowo-Naczyniowych Polskiego Towarzystwa Kardiologicznego
Ponad 15-letnie doświadczenie i wyniki dużych badań obserwacyjnych, na podstawie których tworzone są wytyczne, wskazują na bezpieczeństwo i skuteczność zabiegów przezcewnikowej implantacji „zastawki w zastawkę” (ViV-TAVI, valve-in-valve transcatheter aortic valve implantation), zmniejszając tym samym potrzebę reoperacji u pacjentów wysokiego ryzyka. Oczekuje się, że liczba zabiegów ViV-TAVI w Polsce, szacowana na około 2% wszystkich przezcewnikowej implantacji zastawki aortalnej w 2020 roku, będzie rosła. Niniejszy dokument ma na celu przegląd aspektów proceduralnych ViV-TAVI, w tym odpowiednich metod planowania przedzabiegowego, sposobów optymalizacji wyników hemodynamicznych i ograniczania ryzyka okluzji tętnic wieńcowych. Dokument zawiera również wstępny przegląd wskazań i wytycznych dotyczących ponownego zabiegu TAVI (re-do TAVI) u pacjentów ze zdegenerowanymi zastawkami przezcewnikowymi
- …