14 research outputs found

    The LAGUNA design study- towards giant liquid based underground detectors for neutrino physics and astrophysics and proton decay searches

    Get PDF
    The feasibility of a next generation neutrino observatory in Europe is being considered within the LAGUNA design study. To accommodate giant neutrino detectors and shield them from cosmic rays, a new very large underground infrastructure is required. Seven potential candidate sites in different parts of Europe and at several distances from CERN are being studied: Boulby (UK), Canfranc (Spain), Fr\'ejus (France/Italy), Pyh\"asalmi (Finland), Polkowice-Sieroszowice (Poland), Slanic (Romania) and Umbria (Italy). The design study aims at the comprehensive and coordinated technical assessment of each site, at a coherent cost estimation, and at a prioritization of the sites within the summer 2010.Comment: 5 pages, contribution to the Workshop "European Strategy for Future Neutrino Physics", CERN, Oct. 200

    The LAGUNA design study- towards giant liquid based underground detectors for neutrino physics and astrophysics and proton decay searches

    Get PDF
    The feasibility of a next generation neutrino observatory in Europe is being considered within the LAGUNA design study. To accommodate giant neutrino detectors and shield them from cosmic rays, a new very large underground infrastructure is required. Seven potential candidate sites in different parts of Europe and at several distances from CERN are being studied: Boulby (UK), Canfranc (Spain), Fr\'ejus (France/Italy), Pyh\"asalmi (Finland), Polkowice-Sieroszowice (Poland), Slanic (Romania) and Umbria (Italy). The design study aims at the comprehensive and coordinated technical assessment of each site, at a coherent cost estimation, and at a prioritization of the sites within the summer 2010

    Evaluation of the effectiveness of pollutants’ removal in the sewage treatment plant in Tarnow

    No full text
    W artykule przedstawiono ocenę efektywności oczyszczania ścieków przez Tarnowską Grupową Oczyszczalnie Ścieków. Na podstawie wyników badań fizykochemicznych ścieków surowych i oczyszczonych określono skuteczność zmniejszenia wybranych zanieczyszczeń ścieków. Badano następujące wskaźniki zanieczyszczeń: BZT5, ChZTCr, zawiesinę ogólną, azot ogólny, fosfor ogólny. Badania prowadzono od stycznia 2006 do listopada 2007 roku. W pracy przedstawiono ilość przekroczeń poszczególnych wskaźników w stosunku do wartości dopuszczalnych określonych w pozwoleniu wodno-prawnym. Na podstawie przeprowadzonej analizy badań stwierdzono następującą skuteczność usuwania zanieczyszczeń: BZT5 98,9%, ChZTCr 92,9%, zawiesina ogólna 95,1%, azot ogólny 91,3%, fosfor ogólny 87,4%. Można stwierdzić, że badana oczyszczalnia ścieków działa prawidłowo i oczyszcza ścieki do wartości normatywnej.The article presents evaluation of effectiveness of sewage treatment by the Tarnow Group Sewage Treatment Plant. On the basis of the results of raw and treated sewage physico-chemical analyses, the effectiveness of decreasing the chosen sewage pollutants was evaluated. The following pollutants’ indexes were tested: BOD5, COD, total suspended solids, general nitrogen and general phosphorus. The research period was from January 2006 until November 2007. The paper presents the amount of transgressions of each index in relation to the admissible values from the water-law permission. Basing on the performed analysis the following effectiveness of the pollutants’ removal was evaluated: BOD 98,9%, COD 92,9%, total suspended solids 95,1%, general nitrogen 91,3%, general phosphorus 87,4%. The tested sewage treatment plant may be certified to operate in high quality and the sewage treated by this plant doesn’t threaten the collector of the treated sewage

    Effectiveness of sewage pollutants' reduction in "Kujawy" Sewage Treatment Plant

    No full text
    W artykule przedstawiono skuteczność zmniejszenia zanieczyszczeń ścieków w Zakładzie Oczyszczania Ścieków „KUJAWY”. Oczyszczalnia „KUJAWY” przeznaczona jest do oczyszczania ścieków bytowych z dzielnicy Nowa Huta dla miasta Krakowa. Przepustowość oczyszczalni wynosi 80 000 m3.d-1. Badania przeprowadzono w okresie od 01.04.2006 do 31.03.2007 roku. Analizy wyników dokonano na podstawie stężenia ścieków surowych i oczyszczonych. Analizie poddano trzy wskaźniki zanieczyszczeń z grupy podstawowej: BZT5, ChZTCr i zawiesinę ogólną oraz dwa z grupy eutroficznej: azot ogólny i fosfor ogólny. Na podstawie przeprowadzonej analizy wyników określono średnią skuteczność zmniejszenia wskaźnika BZT5 na poziomie 98,5%. ChZTCr – 96,0%, zawiesiny ogólnej – 98,2%, azotu ogólnego – 73,7% oraz fosforu ogólnego – 91,4%.The article presents effectiveness of sewage pollutants’ reduction in Sewage Treatment Plant „KUJAWY”. Treatment plant “KUJAWY” is meant to neutralise living sewage from Nowa Huta quarter for Krakow city. Capacity of the treatment plant is 80 000 m3.d-1. The research was carried out in the period from 01.04.2006 to 31.03.2007. Results’ analysis was performed on the basis of raw and treated sewage concentration. Three pollutants’ indexes from the basic group were analysed: BOD5, CODCr and total suspended solids and two indexes from the eutrophic group: general nitrogen and general phosphorus. Basing on the results’analysis, mean effectiveness of BOD5 reduction was defined on the level of 98,5%, CODCr – 96,0%, total suspended solids– 98,2%, general nitrogen– 73,7% and general phosphorus – 91,4%

    Evaluation of sewage treatment efficiency in the sewage treatment plant in Nowy Sacz-Wielopole

    No full text
    W artykule przedstawiono ocenę działania oczyszczalni ścieków w Nowym Sączu-Wielopolu. Okres badań obejmował przedział czasowy od stycznia do listopada 2009 roku. Badano następujące wskaźniki zanieczyszczenia ścieków: BZT5, ChZTCr, zawiesinę ogólną, azot ogólny oraz fosfor ogólny. Na podstawie zebranych danych dokonano analizy skuteczności zmniejszania zanieczyszczeń dla poszczególnych wskaźników. Dodatkowo zestawiono ilości ścieków dopływających do oczyszczalni w rozbiciu na miesiące rozpatrywanego okresu. Ponadto określono ilość przekroczeń wartości dopuszczalnych wskaźników w stosunku do przedstawionych w pozwoleniu wodno-prawnym wydanym przez stosowny organ. Na podstawie przeprowadzonej analizy stwierdzono następującą średnią skuteczność zmniejszania zanieczyszczeń: BZT5 – 98,10%, ChZTCr – 92,76%, zawiesina ogólna – 92,66% , azot ogólny – 82,43%, fosfor ogólny – 93,41%. Stwierdzono po jednym przekroczeniu ChZTCr i zawiesiny ogólnej w stosunku do wartości dopuszczalnych przedstawionych w pozwoleniu wodno-prawnym. Wartości pozostałych wskaźników w ściekach oczyszczonych były poniżej wartości dopuszczalnej. Oczyszczalnia działa bardzo dobrze a niskie wartości stężeń badanych wskaźników w ściekach oczyszczonych świadczą o poprawnym przebiegu procesów zachodzących w urządzeniach do biologicznego oczyszczania ścieków. Fosfor był usuwany w wysokim stopniu dzięki zastosowaniu wspomagania poprzez chemiczne strącanie.The article presents evaluation of the sewage treatment plant operation in Nowy Sacz-Wielopole. The research was conducted in a period from January to November 2009. The following sewage pollution indexes were analyzed: BOD5, CODCr, total suspended solids, general nitrogen and general phosphorus. On the basis of the gathered data the analysis of pollutants’ removal efficiency was evaluated for each index. Additionally, the amount of sewage which flew into the treatment plant was compared in each month of the research period. Moreover, the amount of transgressions of the admissible values in relation to the indexes presented in the water-law permission was described. On the basis of the carried out research, the following average effectiveness of pollutants’ removal was found: BOD5 – 98.10%, CODCr – 92.76%, total suspended solids – 92.66%, general nitrogen – 82.43%, general phosphorus – 93.41%. One transgression was found for CODCr and for total suspended solids, respectively, in relation to the admissible values presented in the water-law permission. Values of other indexes in the treated sewage were lower than the admissible value. The sewage treatment plant operates very well and low values of the tested indexes in the analyzed sewage prove the correctness of the processes in the biological sewage treatment appliances

    Evaluation of performance household sewage treatment plant based on a horizontal flow sand filter

    No full text
    Celem pracy jest ocena działania przydomowej oczyszczalni ścieków, opar-tej na filtrze piaskowym o przepływie poziomym. Przeprowadzono analizy fizyko-chemiczne wybranych wskaźników zanie-czyszczeń (BZT5, ChZTCr, zawiesina ogólna, fosfor ogólny) i porównano je do ak-tualnie obowiązujących wartości w ściekach oczyszczonych zawartych w Rozpo-rządzeniu Ministra Środowiska z dnia 24 lipca 2006 r. Na tej podstawie określono skuteczność usuwania zanieczyszczeń. Próby ścieków surowych, wstępnie oczysz-czonych i oczyszczonych, pobierane były od grudnia 2008 do marca 2009 roku. Analiza fizyko-chemiczna została przeprowadzona w Laboratorium Katedry Inży-nierii Sanitarnej i Gospodarki Wodnej Uniwersytetu Rolniczego im. Hugona Koł-łątaja w Krakowie. Zgromadzone wyniki badań, oraz ich analiza przeprowadzona w pracy, ukazały sprawne działanie przydomowej oczyszczalni.The work aimed at the assessment of working of a household sewage treatment plant based on a horizontal flow sand filter. Physicochemical analyses of chosen pollution indexes (BZT5, ChZTCr, total suspension, total phosphorus) were carried out and compared with currently in force values of these indexes according to the Regulation of the Minister of the Environment of 24th July 2006. On this basis the operation of the sewage treatment plant was assessed. Raw, initially treated and treated sewage samples were taken from December 2008 to March 2009. Physicochemical analysis was carried out in the Laboratory of the Department of Sanitary Engineering and Water Management of the University of Agriculture in Kraków. The gathered results of tests and their analysis conducted in the paper showed the proper working of the household sewage treatment plant

    Analysis of chosen hydrodynamics parameters along the rapid hydraulic structure with increased roughness - the Sanoczek stream

    No full text
    W ostatnim czasie istnieje coraz bardziej ożywiona dyskusja na temat nowoczesnych budowli wodnych inżynierii rzecznej, które spełniałyby wymagania stawiane przez ekologów. Jedną z takich budowli jest bystrze o zwiększonej szorstkości. W niniejszej pracy przedstawiono jeden z tego typu obiektów. Znajduje się on na potoku Sanoczek, w Bieszczadach. Jednym z ważniejszych czynników powodujących naruszenie stabilności bystrza i koryta w strefie jego oddziaływania jest prędkość maksymalna występująca na bystrzu lub tuż poniżej. Celem niniejszej pracy jest określenie rozkładu prędkości na bystrzu na potoku Sanoczek i w strefie jego oddziaływania. Rozszerzenie badań o strefy oddziaływania bystrza jest bardzo istotne do ustalenia warunków stabilności nie tylko bystrza, ale także koryta powyżej i poniżej bystrza. Pomiary rozkładu prędkości w korycie powyżej i poniżej bystrza miały na celu zbadanie czy warunki hydrauliczne przepływu są porównywalne, co świadczyłoby o wystarczającej redukcji zwiększonej energii przepływającego strumienia. W pracy dokonano także analizy prędkości stycznych, prędkości średniej i dynamicznej, występujących na bystrzu i w strefie jego oddziaływania. W celu dokładnej analizy pracy bystrza, poza głównym celem pracy, postawiono także cel dodatkowy określenia charakteru przepływu na bystrzu i w strefie jego oddziaływania.At the present time once can easily noticed very lively discussion about introducing modern, ecological friendly hydraulic structures in river training works which are suppose to stay up to the standards given by hydrobiologists, ecologists as well as fluvial geomorphologists. One of the proposals of such structures is a rapid hydraulic structure (RHS) with increased roughness. Along the presented paper such structure is presented. It was constructed within the river channel of the Sanoczek Stream in the Bieszczady Mountains, a part of Polish Carpathians. One of the main problems connected with changes of stability of hydraulic structures (in that case also with RHS) is velocity of running water causing huge turbulence and shear stresses. Thus, the objective of the following paper is to present the distribution of velocities values along the RHS and within the region of its influence. The main aim of the research was to describe conditions upstream and downstream of the structure and compare them in terms of stability of the RHS. Parallel with the main aim, the distribution of shear stresses as well as shear velocities along the RHS apron and the region within its influence are also presented. The work was conducted in Agricultural University of Krakow and was a part of the master thesis

    ISRM Suggested Methods for Determining the Creep Characteristics of Rock

    No full text
    It is important to note that creep is only one aspect of the time-dependent behavior of rocks. In Fig. 1, three cases are illustrated with respect to the complete stress–strain curve: creep, i.e., increasing strain when the stress is held constant; stress relaxation, i.e., decreasing stress when the strain is held constant; and a combination of both, when the rock unloads along a chosen unloading path. This ISRM suggested method deals only with the case of creep, which is particularly relevant for cases where the applied load or stress is kept constant. Creep tests have also been carried out on soft rocks such as tuff, shale, lignite, and sandstone, medium-hard rocks such as marble, limestone, and rock salt, and hard rocks such as granite and andesite (i.e., Akagi 1976; Akai et al. 1979, 1984; Ito and Akagi 2001; Berest et al. 2005; Doktan 1983; Passaris 1979; Serata et al. 1968; Wawersik 1983; Okubo et al. 1991, 1993; Masuda et al. 1987, 1988; Ishizuka et al. 1993; Lockner and Byerlee 1977; Boukharov et al. 1995; Fabre and Pellet 2006; Aydan et al. 1995; Chan 1997; Cristescu and Hunsche 1998; Hunsche 1992; Hunsche and Hampel 1999; Ito et al. 1999; Mottahed and Szeki 1982; Perzyna 1966; Slizowski and Lankof 2003; Yang et al. 1999). These experiments were mostly carried out under compressive loading conditions. There are few studies on rocks using creep tests under a tensile loading regime (Ito and Sasajima 1980, 1987; Ito et al. 2008; Aydan et al. 2011). In particular, shallow underground openings may be subjected to a sustained tensile stress regime, which requires the creep behavior of rocks under such conditions.http://link.springer.com/journal/603hb201
    corecore