14 research outputs found
The LAGUNA design study- towards giant liquid based underground detectors for neutrino physics and astrophysics and proton decay searches
The feasibility of a next generation neutrino observatory in Europe is being
considered within the LAGUNA design study. To accommodate giant neutrino
detectors and shield them from cosmic rays, a new very large underground
infrastructure is required. Seven potential candidate sites in different parts
of Europe and at several distances from CERN are being studied: Boulby (UK),
Canfranc (Spain), Fr\'ejus (France/Italy), Pyh\"asalmi (Finland),
Polkowice-Sieroszowice (Poland), Slanic (Romania) and Umbria (Italy). The
design study aims at the comprehensive and coordinated technical assessment of
each site, at a coherent cost estimation, and at a prioritization of the sites
within the summer 2010.Comment: 5 pages, contribution to the Workshop "European Strategy for Future
Neutrino Physics", CERN, Oct. 200
The LAGUNA design study- towards giant liquid based underground detectors for neutrino physics and astrophysics and proton decay searches
The feasibility of a next generation neutrino observatory in Europe is being considered within the LAGUNA design study. To accommodate giant neutrino detectors and shield them from cosmic rays, a new very large underground infrastructure is required. Seven potential candidate sites in different parts of Europe and at several distances from CERN are being studied: Boulby (UK), Canfranc (Spain), Fr\'ejus (France/Italy), Pyh\"asalmi (Finland), Polkowice-Sieroszowice (Poland), Slanic (Romania) and Umbria (Italy). The design study aims at the comprehensive and coordinated technical assessment of each site, at a coherent cost estimation, and at a prioritization of the sites within the summer 2010
Evaluation of the effectiveness of pollutants’ removal in the sewage treatment plant in Tarnow
W artykule przedstawiono ocenę efektywności oczyszczania ścieków przez
Tarnowską Grupową Oczyszczalnie Ścieków. Na podstawie wyników badań fizykochemicznych
ścieków surowych i oczyszczonych określono skuteczność
zmniejszenia wybranych zanieczyszczeń ścieków. Badano następujące wskaźniki
zanieczyszczeń: BZT5, ChZTCr, zawiesinę ogólną, azot ogólny, fosfor ogólny.
Badania prowadzono od stycznia 2006 do listopada 2007 roku. W pracy przedstawiono
ilość przekroczeń poszczególnych wskaźników w stosunku do wartości dopuszczalnych
określonych w pozwoleniu wodno-prawnym. Na podstawie przeprowadzonej
analizy badań stwierdzono następującą skuteczność usuwania
zanieczyszczeń: BZT5 98,9%, ChZTCr 92,9%, zawiesina ogólna 95,1%, azot ogólny
91,3%, fosfor ogólny 87,4%. Można stwierdzić, że badana oczyszczalnia ścieków
działa prawidłowo i oczyszcza ścieki do wartości normatywnej.The article presents evaluation of effectiveness of sewage treatment by the
Tarnow Group Sewage Treatment Plant. On the basis of the results of raw and
treated sewage physico-chemical analyses, the effectiveness of decreasing the chosen
sewage pollutants was evaluated. The following pollutants’ indexes were
tested: BOD5, COD, total suspended solids, general nitrogen and general
phosphorus. The research period was from January 2006 until November 2007. The paper presents the amount of transgressions of each index in relation to the
admissible values from the water-law permission. Basing on the performed analysis
the following effectiveness of the pollutants’ removal was evaluated: BOD
98,9%, COD 92,9%, total suspended solids 95,1%, general nitrogen 91,3%, general
phosphorus 87,4%. The tested sewage treatment plant may be certified to operate
in high quality and the sewage treated by this plant doesn’t threaten the collector
of the treated sewage
Effectiveness of sewage pollutants' reduction in "Kujawy" Sewage Treatment Plant
W artykule przedstawiono skuteczność zmniejszenia zanieczyszczeń ścieków
w Zakładzie Oczyszczania Ścieków „KUJAWY”. Oczyszczalnia „KUJAWY”
przeznaczona jest do oczyszczania ścieków bytowych z dzielnicy Nowa Huta
dla miasta Krakowa. Przepustowość oczyszczalni wynosi 80 000 m3.d-1.
Badania przeprowadzono w okresie od 01.04.2006 do 31.03.2007 roku.
Analizy wyników dokonano na podstawie stężenia ścieków surowych i oczyszczonych.
Analizie poddano trzy wskaźniki zanieczyszczeń z grupy podstawowej:
BZT5, ChZTCr i zawiesinę ogólną oraz dwa z grupy eutroficznej: azot ogólny i fosfor
ogólny.
Na podstawie przeprowadzonej analizy wyników określono średnią skuteczność
zmniejszenia wskaźnika BZT5 na poziomie 98,5%. ChZTCr – 96,0%,
zawiesiny ogólnej – 98,2%, azotu ogólnego – 73,7% oraz fosforu ogólnego –
91,4%.The article presents effectiveness of sewage pollutants’ reduction in Sewage
Treatment Plant „KUJAWY”. Treatment plant “KUJAWY” is meant to neutralise
living sewage from Nowa Huta quarter for Krakow city. Capacity of the treatment
plant is 80 000 m3.d-1. The research was carried out in the period from 01.04.2006
to 31.03.2007. Results’ analysis was performed on the basis of raw and treated
sewage concentration. Three pollutants’ indexes from the basic group were analysed:
BOD5, CODCr and total suspended solids and two indexes from the eutrophic
group: general nitrogen and general phosphorus. Basing on the results’analysis, mean effectiveness of BOD5 reduction was defined on the level of 98,5%,
CODCr – 96,0%, total suspended solids– 98,2%, general nitrogen– 73,7% and
general phosphorus – 91,4%
Evaluation of sewage treatment efficiency in the sewage treatment plant in Nowy Sacz-Wielopole
W artykule przedstawiono ocenę działania oczyszczalni ścieków w Nowym
Sączu-Wielopolu. Okres badań obejmował przedział czasowy od stycznia do listopada
2009 roku. Badano następujące wskaźniki zanieczyszczenia ścieków: BZT5,
ChZTCr, zawiesinę ogólną, azot ogólny oraz fosfor ogólny. Na podstawie zebranych
danych dokonano analizy skuteczności zmniejszania zanieczyszczeń dla poszczególnych
wskaźników. Dodatkowo zestawiono ilości ścieków dopływających
do oczyszczalni w rozbiciu na miesiące rozpatrywanego okresu. Ponadto określono
ilość przekroczeń wartości dopuszczalnych wskaźników w stosunku do przedstawionych
w pozwoleniu wodno-prawnym wydanym przez stosowny organ.
Na podstawie przeprowadzonej analizy stwierdzono następującą średnią
skuteczność zmniejszania zanieczyszczeń: BZT5 – 98,10%, ChZTCr – 92,76%,
zawiesina ogólna – 92,66% , azot ogólny – 82,43%, fosfor ogólny – 93,41%.
Stwierdzono po jednym przekroczeniu ChZTCr i zawiesiny ogólnej w stosunku do
wartości dopuszczalnych przedstawionych w pozwoleniu wodno-prawnym. Wartości
pozostałych wskaźników w ściekach oczyszczonych były poniżej wartości
dopuszczalnej.
Oczyszczalnia działa bardzo dobrze a niskie wartości stężeń badanych
wskaźników w ściekach oczyszczonych świadczą o poprawnym przebiegu procesów
zachodzących w urządzeniach do biologicznego oczyszczania ścieków. Fosfor
był usuwany w wysokim stopniu dzięki zastosowaniu wspomagania poprzez
chemiczne strącanie.The article presents evaluation of the sewage treatment plant operation in
Nowy Sacz-Wielopole. The research was conducted in a period from January to
November 2009. The following sewage pollution indexes were analyzed: BOD5,
CODCr, total suspended solids, general nitrogen and general phosphorus. On the
basis of the gathered data the analysis of pollutants’ removal efficiency was
evaluated for each index. Additionally, the amount of sewage which flew into the
treatment plant was compared in each month of the research period. Moreover,
the amount of transgressions of the admissible values in relation to the indexes
presented in the water-law permission was described.
On the basis of the carried out research, the following average effectiveness
of pollutants’ removal was found: BOD5 – 98.10%, CODCr – 92.76%, total
suspended solids – 92.66%, general nitrogen – 82.43%, general phosphorus –
93.41%. One transgression was found for CODCr and for total suspended solids,
respectively, in relation to the admissible values presented in the water-law permission.
Values of other indexes in the treated sewage were lower than the admissible
value.
The sewage treatment plant operates very well and low values of the tested
indexes in the analyzed sewage prove the correctness of the processes in the biological
sewage treatment appliances
Evaluation of performance household sewage treatment plant based on a horizontal flow sand filter
Celem pracy jest ocena działania przydomowej oczyszczalni ścieków, opar-tej na filtrze piaskowym o przepływie poziomym.
Przeprowadzono analizy fizyko-chemiczne wybranych wskaźników zanie-czyszczeń (BZT5, ChZTCr, zawiesina ogólna, fosfor ogólny) i porównano je do ak-tualnie obowiązujących wartości w ściekach oczyszczonych zawartych w Rozpo-rządzeniu Ministra Środowiska z dnia 24 lipca 2006 r. Na tej podstawie określono skuteczność usuwania zanieczyszczeń. Próby ścieków surowych, wstępnie oczysz-czonych i oczyszczonych, pobierane były od grudnia 2008 do marca 2009 roku. Analiza fizyko-chemiczna została przeprowadzona w Laboratorium Katedry Inży-nierii Sanitarnej i Gospodarki Wodnej Uniwersytetu Rolniczego im. Hugona Koł-łątaja w Krakowie. Zgromadzone wyniki badań, oraz ich analiza przeprowadzona w pracy, ukazały sprawne działanie przydomowej oczyszczalni.The work aimed at the assessment of working of a household sewage treatment
plant based on a horizontal flow sand filter.
Physicochemical analyses of chosen pollution indexes (BZT5, ChZTCr,
total suspension, total phosphorus) were carried out and compared with currently
in force values of these indexes according to the Regulation of the Minister of the Environment of 24th July 2006. On this basis the operation of the sewage treatment
plant was assessed. Raw, initially treated and treated sewage samples were
taken from December 2008 to March 2009. Physicochemical analysis was carried
out in the Laboratory of the Department of Sanitary Engineering and Water Management
of the University of Agriculture in Kraków. The gathered results of tests
and their analysis conducted in the paper showed the proper working of the
household sewage treatment plant
Analysis of chosen hydrodynamics parameters along the rapid hydraulic structure with increased roughness - the Sanoczek stream
W ostatnim czasie istnieje coraz bardziej ożywiona dyskusja na temat
nowoczesnych budowli wodnych inżynierii rzecznej, które spełniałyby wymagania
stawiane przez ekologów. Jedną z takich budowli jest bystrze o zwiększonej
szorstkości. W niniejszej pracy przedstawiono jeden z tego typu obiektów. Znajduje
się on na potoku Sanoczek, w Bieszczadach.
Jednym z ważniejszych czynników powodujących naruszenie stabilności
bystrza i koryta w strefie jego oddziaływania jest prędkość maksymalna występująca
na bystrzu lub tuż poniżej. Celem niniejszej pracy jest określenie rozkładu
prędkości na bystrzu na potoku Sanoczek i w strefie jego oddziaływania.
Rozszerzenie badań o strefy oddziaływania bystrza jest bardzo istotne do
ustalenia warunków stabilności nie tylko bystrza, ale także koryta powyżej i poniżej
bystrza. Pomiary rozkładu prędkości w korycie powyżej i poniżej bystrza miały
na celu zbadanie czy warunki hydrauliczne przepływu są porównywalne, co
świadczyłoby o wystarczającej redukcji zwiększonej energii przepływającego
strumienia.
W pracy dokonano także analizy prędkości stycznych, prędkości średniej
i dynamicznej, występujących na bystrzu i w strefie jego oddziaływania. W celu
dokładnej analizy pracy bystrza, poza głównym celem pracy, postawiono także cel
dodatkowy określenia charakteru przepływu na bystrzu i w strefie jego oddziaływania.At the present time once can easily noticed very lively discussion about
introducing modern, ecological friendly hydraulic structures in river training
works which are suppose to stay up to the standards given by hydrobiologists,
ecologists as well as fluvial geomorphologists. One of the proposals of such structures
is a rapid hydraulic structure (RHS) with increased roughness. Along the
presented paper such structure is presented. It was constructed within the river
channel of the Sanoczek Stream in the Bieszczady Mountains, a part of Polish
Carpathians. One of the main problems connected with changes of stability of
hydraulic structures (in that case also with RHS) is velocity of running water causing
huge turbulence and shear stresses. Thus, the objective of the following paper
is to present the distribution of velocities values along the RHS and within the
region of its influence. The main aim of the research was to describe conditions
upstream and downstream of the structure and compare them in terms of stability
of the RHS. Parallel with the main aim, the distribution of shear stresses as well as
shear velocities along the RHS apron and the region within its influence are also
presented. The work was conducted in Agricultural University of Krakow and was
a part of the master thesis
ISRM Suggested Methods for Determining the Creep Characteristics of Rock
It is important to note that creep is only one aspect of the
time-dependent behavior of rocks. In Fig. 1, three cases are
illustrated with respect to the complete stress–strain curve:
creep, i.e., increasing strain when the stress is held constant;
stress relaxation, i.e., decreasing stress when the
strain is held constant; and a combination of both, when the
rock unloads along a chosen unloading path. This ISRM
suggested method deals only with the case of creep, which
is particularly relevant for cases where the applied load or
stress is kept constant.
Creep tests have also been carried out on soft rocks such as
tuff, shale, lignite, and sandstone, medium-hard rocks such as marble, limestone, and rock salt, and hard rocks such as
granite and andesite (i.e., Akagi 1976; Akai et al. 1979,
1984; Ito and Akagi 2001; Berest et al. 2005; Doktan 1983;
Passaris 1979; Serata et al. 1968; Wawersik 1983; Okubo
et al. 1991, 1993; Masuda et al. 1987, 1988; Ishizuka et al.
1993; Lockner and Byerlee 1977; Boukharov et al. 1995;
Fabre and Pellet 2006; Aydan et al. 1995; Chan 1997;
Cristescu and Hunsche 1998; Hunsche 1992; Hunsche and
Hampel 1999; Ito et al. 1999; Mottahed and Szeki 1982;
Perzyna 1966; Slizowski and Lankof 2003; Yang et al.
1999). These experiments were mostly carried out under
compressive loading conditions.
There are few studies on rocks using creep tests under a
tensile loading regime (Ito and Sasajima 1980, 1987; Ito
et al. 2008; Aydan et al. 2011). In particular, shallow
underground openings may be subjected to a sustained
tensile stress regime, which requires the creep behavior of
rocks under such conditions.http://link.springer.com/journal/603hb201