42 research outputs found

    C3TM: CEI CCD charge transfer model for radiation damage analysis and testing

    Get PDF
    Radiation induced defects in the silicon lattice of Charge Couple Devices (CCDs) are able to trap electrons during read out and thus create a smearing effect that is detrimental to the scientific data. To further our understanding of the positions and properties of individual radiation-induced traps and how they affect space- borne CCD performance, we have created the Centre for Electronic Imaging (CEI) CCD Charge Transfer Model (C3TM). This model simulates the physical processes taking place when transferring signal through a radiation damaged CCD. C3TM is a Monte Carlo model based on Shockley-Read-Hall theory, and it mimics the physical properties in the CCD as closely as possible. It runs on a sub-electrode level taking device specific charge density simulations made with professional TCAD software as direct input. Each trap can be specified with 3D positional information, emission time constant and other physical properties. The model is therefore also able to simulate multi-level clocking and other complex clocking schemes, such as trap pumping

    Importance of charge capture in interphase regions during readout of charge-coupled devices

    Get PDF
    The current understanding of charge transfer dynamics in charge-coupled devices (CCDs) is that charge is moved so quickly from one phase to the next in a clocking sequence and with a density so low that trapping of charge in the interphase regions is negligible. However, simulation capabilities developed at the Centre for Electronic Imaging, which includes direct input of electron density simulations, have made it possible to investigate this assumption further. As part of the radiation testing campaign of the Euclid CCD273 devices, data have been obtained using the trap pumping method, a method that can be used to identify and characterize single defects within CCDs. Combining these data with simulations, we find that trapping during the transfer of charge among phases is indeed necessary to explain the results of the data analysis. This result could influence not only trap pumping theory and how trap pumping should be performed but also how a radiation-damaged CCD is readout in the most optimal way

    Evolution and impact of defects in a p-channel CCD after cryogenic proton-irradiation

    Get PDF
    P-channel CCDs have been shown to display improved tolerance to radiation-induced charge transfer inefficiency (CTI) when compared to n-channel CCDs. However, the defect distribution formed during irradiation is expected to be temperature dependent due to the differences in lattice energy caused by a temperature change. This has been tested through defect analysis of two p-channel e2v CCD204 devices, one irradiated at room temperature and one at a cryogenic temperature (153K). Analysis is performed using the method of single trap pumping. The dominant charge trapping defects at these conditions have been identified as the donor level of the silicon divacancy and the carbon interstitial defect. The defect parameters are analysed both immediately post irradiation and following several subsequent room-temperature anneal phases up until a cumulative anneal time of approximately 10 months. We have also simulated charge transfer in an irradiated CCD pixel using the defect distribution from both the room-temperature and cryogenic case, to study how the changes affect imaging performance. The results demonstrate the importance of cryogenic irradiation and annealing studies, with large variations seen in the defect distribution when compared to a device irradiated at room-temperature, which is the current standard procedure for radiation-tolerance testing

    Towards high-resolution astronomical imaging

    Full text link
    This paper is a report from a recent meeting on "the Future of high-resolution imaging in the visible and infrared", reviewing the astronomical drivers for development and the technological advances that might boost performance. Each of the authors listed contributed a section themselves.Comment: 6 pages, 7 figures, 11 contributors, Accepted for publication in Astronomy & Geophysics of the RAS, June 2019 issu

    Comparing simulations and test data of a radiation damaged charge-coupled device for the Euclid mission

    Get PDF
    The visible imager instrument on board the Euclid mission is a weak-lensing experiment that depends on very precise shape measurements of distant galaxies obtained by a large charge-coupled device (CCD) array. Due to the harsh radiative environment outside the Earth’s atmosphere, it is anticipated that the CCDs over the mission lifetime will be degraded to an extent that these measurements will be possible only through the correction of radiation damage effects. We have therefore created a Monte Carlo model that simulates the physical processes taking place when transferring signals through a radiation-damaged CCD. The software is based on Shockley–Read–Hall theory and is made to mimic the physical properties in the CCD as closely as possible. The code runs on a single electrode level and takes the three-dimensional trap position, potential structure of the pixel, and multilevel clocking into account. A key element of the model is that it also takes device specific simulations of electron density as a direct input, thereby avoiding making any analytical assumptions about the size and density of the charge cloud. This paper illustrates how test data and simulated data can be compared in order to further our understanding of the positions and properties of the individual radiation-induced traps

    A pair of temperate sub-Neptunes transiting the star EPIC 212737443

    Get PDF
    We report the validation of a new planetary system around the K3 star EPIC 212737443 using a combination of K2 photometry, follow-up high resolution imaging and spectroscopy. The system consists of two sub-Neptune sized transiting planets with radii of 2.6R⊕, and 2.7R⊕, with orbital periods of 13.6 days and 65.5 days, equilibrium temperatures of 536 K and 316 K respectively. In the context of validated K2 systems, the outer planet has the longest precisely measured orbital period, as well as the lowest equilibrium temperature for a planet orbiting a star of spectral type earlier than M. The two planets in this system have a mutual Hill radius of ΔRH = 36, larger than most other known transiting multi-planet systems, suggesting the existence of another (possibly non-transiting) planet, or that the system is not maximally packed