259 research outputs found
Technological Advances in Universal Neonatal Hearing Screening (UNHS)
Within the last decade, numerous new challenges have appeared in the UNHS arena, such as (i) the need to validate the automated OAE/ABR screeners; (ii) the need to qualify the responses from the automated devices; (iii) the need to obtain additional information (i.e., hearing threshold) for the subject under assessment, in a short period of time; (iv) and the need to integrate numerous measurements in a single portable automated device. To respond to these clinical demands, several new methodologies have been introduced to the UNHS clinical practice. In this context, the aim of this chapter is to provide information on these new technological trends
Detection of hearing losses (HL) via transient-evoked otoacoustic emissions: towards an automatic classification
Transiently evoked otoacoustic emissions (TEOAEs) are routinely used in the hearing assessment of the auditory periphery. The major contribution of TEOAEs is the early detection of hearing losses in neonates, children, and adults. The evaluation of TEOAE responses by specific signal decomposition techniques offers numerous advantages for current and future research. One methodology, based on recurrence quantification analysis (RQA), can identify adult subjects presenting sensorineural hearing impairments. In two previous papers, the RQA-based approach was successfully applied in identifying and classifying cases presenting noise and age related hearing losses. The current work investigates further two aspects of the previously proposed RQA-based analysis for hearing loss detection: (i) the reliability of a Training set built from different numbers of ears with normal hearing, and (ii) the threshold set of values of the key hearing loss detecting parameter RAD2D.Results:The Training set built from 158 healthy ears was found to be quite reliable and a similar but slightly minor performance was observed for the training set of 118 normal subjects, used in the past; the proposed ROC-curve method, optimizing the values of RAD2D, shows improved sensibility and specificity in one class discrimination.Conclusions.A complete and simplified procedure, based on the combined use of the traditional TEOAE reproducibility value and on values from the RQA-based RAD2D parameter, is proposed as an improved automatic classifier, in terms of sensitivity and specificity, for different types of hearing losses
Speech-Evoked Brainstem Response
The auditory brainstem response (ABR) is a clinical tool to assess the neural functionality of the auditory brainstem. The use of verbal stimuli in ABR protocols has provided important information of how the speech stimuli are processed by the brainstem structure. The perception of speech sounds seems to begin in the brainstem, which has an important role in the reading process and the phonological acquisition speech ABR assessment allows the identification of fine-grained auditory processing deficits, which do not appear in click evoked ABR responses. The syllable /da/ is commonly used by speech ABR assessment due to it being considered a universal syllable and allows it to be applied in different countries with good clinical assertiveness. The speech ABR is a objective, fast procedure that can be applied to very young subjects. It be utilized in different languages and can provide differential diagnoses of diseases with similar symptoms, as an effective biomarker of auditory processing disorders present in various diseases, such as dyslexia, specific language impairment, hearing loss, auditory processing disorders, otitis media, and scholastic difficulties. Speech ABR protocols can assist in the detection, treatment, and monitoring of various types of hearing impairments
Sense of taste in patients after cochlear implantation-preliminary study
Background: Taste is the leading sense in how we determine the quality of consumed food. Proper gustatory sensation largely determines the well-being and health of an organism, and this affects their quality of life.Objectives: The aim of the present study was to estimate the risk of early taste disorders following implantation surgery.
Methods: Twenty patients underwent a taste test before, 1 day after, and 1 month after cochlear implantation. The taste sensations of sweet, sour, salty, and bitter were determined.
Results: Statistical analysis showed no significant differences (p > 0.05) between individual tests among the entire study group. After dividing the respondents into smoking (n=6) and non-smoking (n=14) groups, only a weak correlation (p =0.043) was found between the results of the first and second examination in the smoker group. However, a statistically significant decrease in the number of saline-sensitive (p<0.001) and acid-sensitive (p = 0.042) subjects was observed.
Conclusion: These findings suggest that people after a cochlear implant may have transient taste disorders. Taste disorder called dysgeusia may be an early complication after the implantation procedure contributing to deterioration of patients quality of life.
Keywords: Sense of taste; taste disorders; cochlear implant surgery; quality of life, partial deafness treatment
Detection of age-related hearing losses (Arhl) via transient-evoked otoacoustic emissions
Purpose: The objective of the study was to identify subjects presenting hearing deficits, specifically age-related hearing losses (ARHL), via objective assessment methodologies. Materials and Methods: Initially, 259 subjects (165 men, 94 women) were enrolled in the study. After the application of inclusion criteria, the final number was reduced to 88 subjects (49.8 ± 19.1 ys) subdivided into 64 normal and 83 ARHL cases. The subjects were assessed with traditional audiometry tests and with transiently evoked otoacoustic emissions (TEOAEs). Since each ear has its own acoustic signature, the TEOAE analyses were conducted in terms of ears and not subjects. The TEOAE data were processed by traditional and recurrence quantification analyses, leading to the estimation of the WWR (whole waveform reproducibility) and the new RAD2D (2-dimensional radius) parameters. A plot of WWR vs RAD2D was used to optimize the classification of the cases presenting ARHL. Results: By using a WWR value of 70% as a classifier, the sensitivity of TEOAEs was estimated as 75.9% and the specificity as 89.1%. By using the RAD2D parameter (with a cutoff value of 1.78), a sensitivity value of 80.7% and a specificity value of 71.9% were obtained. When both parameters were used, a sensitivity value of 85.5% and a specificity value of 92.2% were estimated. In the latter classification paradigm, the number of false negatives decreased from 20 to 12 out of 83 ears (14%). Conclusion: In adult hearing screening assessments, the proposed method optimizes the identification of subjects with a hearing impairment correlated to the presence of age-related hearing loss
Cloning and sequence analysis of cDNAs encoding the cytosolic precursors of subunits GapA and GapB of chloroplast glyceraldehyde-3-phosphate dehydrogenase from pea and spinach
Chloroplast glyceraldehyde-3-phosphate dehydrogenase (GAPDH) is composed of two different subunits, GapA and GapB. cDNA clones containing the entire coding sequences of the cytosolic precursors for GapA from pea and for GapB from pea and spinach have been identified, sequenced and the derived amino acid sequences have been compared to the corresponding sequences from tobacco, maize and mustard. These comparisons show that GapB differs from GapA in about 20% of its amino acid residues and by the presence of a flexible and negatively charged C-terminal extension, possibly responsible for the observed association of the enzyme with chloroplast envelopes in vitro. This C-terminal extension (29 or 30 residues) may be susceptible to proteolytic cleavage thereby leading to a conversion of chloroplast GAPDH isoenzyme I into isoenzyme II. Evolutionary rate comparisons at the amino acid sequence level show that chloroplast GapA and GapB evolve roughly two-fold slower than their cytosolic counterpart GapC. GapA and GapB transit peptides evolve about 10 times faster than the corresponding mature subunits. They are relatively long (68 and 83 residues for pea GapA and spinach GapB respectively) and share a similar amino acid framework with other chloroplast transit peptides
Speech Perception Changes in the Acoustically Aided, Nonimplanted Ear after Cochlear Implantation: A Multicenter Study
In recent years there has been an increasing percentage of cochlear implant (CI) users who have usable residual hearing in the contralateral, nonimplanted ear, typically aided by acoustic amplification. This raises the issue of the extent to which the signal presented through the cochlear implant may influence how listeners process information in the acoustically stimulated ear. This multicenter retrospective study examined pre- to postoperative changes in speech perception in the nonimplanted ear, the implanted ear, and both together. Results in the latter two conditions showed the expected increases, but speech perception in the nonimplanted ear showed a modest yet meaningful decrease that could not be completely explained by changes in unaided thresholds, hearing aid malfunction, or several other demographic variables. Decreases in speech perception in the nonimplanted ear were more likely in individuals who had better levels of speech perception in the implanted ear, and in those who had better speech perception in the implanted than in the nonimplanted ear. This raises the possibility that, in some cases, bimodal listeners may rely on the higher quality signal provided by the implant and may disregard or even neglect the input provided by the nonimplanted ear
Cochlear Implantation With Hearing Preservation Yields Significant Benefit for Speech Recognition in Complex Listening Environments
The aim of this study was to assess the benefit of having preserved acoustic hearing in the implanted ear for speech recognition in complex listening environments
Suitable Electrode Choice for Robotic-Assisted Cochlear Implant Surgery: A Systematic Literature Review of Manual Electrode Insertion Adverse Events
BACKGROUND AND OBJECTIVE: The cochlear implant (CI) electrode insertion process is a key step in CI surgery. One of the aims of advances in robotic-assisted CI surgery (RACIS) is to realize better cochlear structure preservation and to precisely control insertion. The aim of this literature review is to gain insight into electrode selection for RACIS by acquiring a thorough knowledge of electrode insertion and related complications from classic CI surgery involving a manual electrode insertion process. METHODS: A systematic electronic search of the literature was carried out using PubMed, Scopus, Cochrane, and Web of Science to find relevant literature on electrode tip fold over (ETFO), electrode scalar deviation (ESD), and electrode migration (EM) from both pre-shaped and straight electrode types. RESULTS: A total of 82 studies that include 8,603 ears implanted with a CI, i.e., pre-shaped (4,869) and straight electrodes (3,734), were evaluated. The rate of ETFO (25 studies, 2,335 ears), ESD (39 studies, 3,073 ears), and EM (18 studies, 3,195 ears) was determined. An incidence rate (±95% CI) of 5.38% (4.4–6.6%) of ETFO, 28.6% (26.6–30.6%) of ESD, and 0.53% (0.2–1.1%) of EM is associated with pre-shaped electrodes, whereas with straight electrodes it was 0.51% (0.1–1.3%), 11% (9.2–13.0%), and 3.2% (2.5–3.95%), respectively. The differences between the pre-shaped and straight electrode types are highly significant (p < 0.001). Laboratory experiments show evidence that robotic insertions of electrodes are less traumatic than manual insertions. The influence of round window (RW) vs. cochleostomy (Coch) was not assessed. CONCLUSION: Considering the current electrode designs available and the reported incidence of insertion complications, the use of straight electrodes in RACIS and conventional CI surgery (and manual insertion) appears to be less traumatic to intracochlear structures compared with pre-shaped electrodes. However, EM of straight electrodes should be anticipated. RACIS has the potential to reduce these complications
- …