8 research outputs found

    Phenotypic characterization of patients with deletions in the 3’-flanking SHOX region

    Get PDF
    Context. Leri–Weill dyschondrosteosis is a clinically variable skeletal dysplasia, caused by SHOX deletion or mutations, or a deletion of enhancer sequences in the 3’-flanking region. Recently, a 47.5 kb recurrent PAR1 deletion downstream of SHOX was reported, but its frequency and clinical importance are still unknown.Objective. This study aims to compare the clinical features of different sizes of deletions in the 3’-flanking SHOX region in order to determine the relevance of the regulatory sequences in this region.Design. We collected DNA from 28 families with deletions in the 3’-PAR1 region. Clinical data were available from 23 index patients and 21 relatives.Results. In 9 families (20 individuals) a large deletion ( ∼ 200–900 kb) was found and in 19 families (35 individuals) a small deletion was demonstrated, equal to the recently described 47.5 kb PAR1 deletion. Median height SDS, sitting height/height ratio SDS and the presence of Madelung deformity in patients with the 47.5 kb deletion were not significantly different from patients with larger deletions. The index patients had a median height SDS which was slightly lower than in their affected family members (p = 0.08). No significant differences were observed between male and female patients.Conclusions. The phenotype of patients with deletions in the 3’-PAR1 region is remarkably variable. Height, sitting height/height ratio and the presence of Madelung deformity were not significantly different between patients with the 47.5 kb recurrent PAR1 deletion and those with larger deletions, suggesting that this enhancer plays an important role in SHOX expression

    Clinical And Biochemical Characteristics And Bone Mineral Density Of Homozygous, Compound Heterozygous And Heterozygous Carriers Of Three Novel Igfals Mutations

    No full text
    Objective: Acid-labile subunit (ALS) deficiency (ACLSD), caused by homozygous or compound heterozygous IGFALS mutations, is associated with moderate short stature, delayed puberty, low serum IGF-I and ALS and extremely low serum IGFBP-3. Its effect on birth weight, head circumference, bone mineral density (BMD), serum IGF-II and IGFBP-2 is uncertain, as well as the phenotype of heterozygous carriers of IGFALS mutations (partial ACLSD). Design: From all available members of five Turkish families, carrying three mutations in exon 2 of IGFALS (c. 1462G > A, p. Asp488Asn (families A, B, E); c. 251A > G, p. Asn84Ser (families C and E) and c. 1477del, p. Arg493fs (family D)), clinical, laboratory and BMD data were collected. Methods: Auxological and biochemical findings were expressed as SDS for age and gender. Ternary complex formation in serum was investigated by size-exclusion chromatography. BMD using DXA bone densitometry was adjusted for height and age (Ha-BMD z-score). Results: In ACLSD (n = 24), mean +/- s.d. height SDS (-2.7 +/- 1.2), head circumference SDS (-2.3 +/- 0.5) and body mass index (BMI) (-0.6 +/- 1.0 SDS) were lower than those in partial ACLSD (n = 26, P <= 0.01) and birth weight SDS (n = 7) tended to be lower (-2.2 +/- 1.1 vs -0.6 +/- 0.3 in partial ACLSD (P = 0.07)). Serum IGF-I was -3.7 +/- 1.4 vs -1.0 +/- 1.0, IGF-II: -5.6 +/- 0.7 vs -1.3 +/- 0.7, ALS: <-4.4 +/- 1.2 vs -2.1 +/- 0.9 and IGFBP-3: -9.0 +/- 1.9 vs -1.6 +/- 0.8 SDS respectively (P < 0.001). Ha-BMD z-score was similar and normal in both groups. Conclusions: To the known phenotype of ACLSD (i. e. short stature, reduced serum levels of IGF-I and ALS, extremely low serum IGFBP-3 and disturbed ternary complex formation), we add reduced birth weight, head circumference and serum IGF-II.WoSScopu

    Rapid and Sensitive Method Using Multiplex Real-Time PCR for Diagnosis of Infections by Influenza A and Influenza B Viruses, Respiratory Syncytial Virus, and Parainfluenza Viruses 1, 2, 3, and 4

    No full text
    Laboratory diagnosis of viral respiratory infections is generally performed by virus isolation in cell culture and immunofluorescent assays. Reverse transcriptase PCR is now recognized as a sensitive and specific alternative for detection of respiratory RNA viruses. A rapid real-time multiplex PCR assay was developed for the detection of influenza A and influenza B viruses, human respiratory syncytial virus (RSV), parainfluenza virus 1 (PIV1), PIV2, PIV3, and PIV4 in a two-tube multiplex reaction which used molecular beacons to discriminate the pathogens. A total of 358 respiratory samples taken over a 1-year period were analyzed by the multiplex assay. The incidence of respiratory viruses detected in these samples was 67 of 358 (19%) and 87 of 358 (24%) by culture and real-time PCR, respectively. Culture detected 3 influenza A virus, 2 influenza B virus, 57 RSV, 2 PIV1, and 2 PIV3 infections. All of these culture-positive samples and an additional 5 influenza A virus, 6 RSV, 2 PIV1, 1 PIV2, 1 PIV3, and 3 PIV4 infections were detected by the multiplex real-time PCR. The application of real-time PCR to clinical samples increases the sensitivity for respiratory viral diagnosis. In addition, results can be obtained within 6 h, which increases clinical relevance. Therefore, use of this real-time PCR assay would improve patient management and infection control

    Development and Clinical Evaluation of an Internally Controlled, Single-Tube Multiplex Real-Time PCR Assay for Detection of Legionella pneumophila and Other Legionella Species

    No full text
    A multiplex real-time PCR assay for detection of Legionella pneumophila and Legionella spp. and including an internal control was designed. Legionella species, L. pneumophila, and the internal control were detected simultaneously by probes labeled with 6-carboxy-fluorescein, hexachlorofluorescein, and indodicarbocyanine, respectively. Therefore, no postamplification analysis was required in order to distinguish the targets. The sensitivity of both assays was 2.5 CFU/ml, and from analysis of 10 culture-positive and 74 culture-negative samples from patients investigated for legionellosis, 100% agreement was observed by both assays in comparison to culture. Four additional positives were found by the multiplex real-time PCR assay in the Legionella culture-negative samples

    Evaluation of Real-Time PCR for Detection of and Discrimination between Bordetella pertussis, Bordetella parapertussis, and Bordetella holmesii for Clinical Diagnosis

    No full text
    PCR is increasingly being used as a diagnostic test for the detection of Bordetella pertussis and Bordetella parapertussis DNA, as it has improved sensitivity and specificity in comparison to conventional techniques. The assay described here uses the two insertion sequences IS481 and IS1001 for B. pertussis and B. parapertussis, respectively, with detection by molecular beacons. The real-time PCR for IS481 detects both B. pertussis and Bordetella holmesii, and the real-time PCR for IS1001 detects both B. parapertussis and B. holmesii. By performing both assays discrimination between B. pertussis and B. parapertussis can be obtained. The sensitivity was 1 to 10 CFU/ml for B. pertussis, 10 CFU/ml for B. parapertussis, and 10 CFU/ml for B. holmesii in both assays. The clinical sensitivity of the B. pertussis assay was not affected by duplexing with an internal control PCR. Real-time PCR, conventional PCR, and culture were performed on 57 clinical samples. Eight of the 57 (14%) were found positive by culture, 19 of 57 (33%) were found positive by conventional PCR, and 22 of 57 (39%) were found positive by real-time PCR. One sample was inhibitory. When the B. pertussis assay was compared with a clinical standard for B. pertussis infection, sensitivity was 38, 83, and 100% and specificity was 100, 97, and 97% for culture, conventional PCR, and real-time PCR, respectively. The real-time PCR designed for B. pertussis and B. parapertussis provides sensitive and specific diagnosis of B. pertussis and B. parapertussis infections and is therefore suitable for implementation in the diagnostic laboratory

    Comparison and Evaluation of Real-Time PCR, Real-Time Nucleic Acid Sequence-Based Amplification, Conventional PCR, and Serology for Diagnosis of Mycoplasma pneumoniae

    No full text
    Mycoplasma pneumoniae is a common cause of community-acquired pneumonia and lower-respiratory-tract infections. Diagnosis has traditionally been obtained by serological diagnosis, but increasingly, molecular techniques have been applied. However, the number of studies actually comparing these assays is limited. The development of a novel duplex real-time PCR assay for detection of M. pneumoniae in the presence of an internal control real-time PCR is described. In addition, real-time nucleic acid sequence-based amplification (NASBA) on an iCycler apparatus is evaluated. These assays were compared to serology and a conventional PCR assay for 106 clinical samples from patients with lower-respiratory-tract infection. Of the 106 samples, 12 (11.3%) were positive by all the molecular methods whereas serology with acute sample and convalescent samples detected 6 (5.6%) and 9 (8.5%), respectively. Clinical symptoms of the patients with Mycoplasma-positive results were compared to those of the other patients with lower-respiratory-tract infections, and it was found that the results for mean lower age numbers as well as the presence of chills, increased erythrocyte sedimentation rate, and raised C-reactive protein levels showed significant differences. Molecular methods are superior for diagnosis of M. pneumoniae, providing more timely diagnosis. In addition, using real-time methods involves less hands-on time and affords the ability to monitor the reaction in the same tube
    corecore