11 research outputs found

    Minimization of Radiation Exposure due to Computed Tomography in Inflammatory Bowel Disease

    Get PDF
    Patient awareness and concern regarding the potential health risks from ionizing radiation have peaked recently (Coakley et al., 2011) following widespread press and media coverage of the projected cancer risks from the increasing use of computed tomography (CT) (Berrington et al., 2007). The typical young and educated patient with inflammatory bowel disease (IBD) may in particular be conscious of his/her exposure to ionising radiation as a result of diagnostic imaging. Cumulative effective doses (CEDs) in patients with IBD have been reported as being high and are rising, primarily due to the more widespread and repeated use of CT (Desmond et al., 2008). Radiologists, technologists, and referring physicians have a responsibility to firstly counsel their patients accurately regarding the actual risks of ionizing radiation exposure; secondly to limit the use of those imaging modalities which involve ionising radiation to clinical situations where they are likely to change management; thirdly to ensure that a diagnostic quality imaging examination is acquired with lowest possible radiation exposure. In this paper, we synopsize available evidence related to radiation exposure and risk and we report advances in low-dose CT technology and examine the role for alternative imaging modalities such as ultrasonography or magnetic resonance imaging which avoid radiation exposure

    Computed tomography dose optimisation in cystic fibrosis: A review.

    Get PDF
    Cystic fibrosis (CF) is the most common autosomal recessive disease of the Caucasian population worldwide, with respiratory disease remaining the most relevant source of morbidity and mortality. Computed tomography (CT) is frequently used for monitoring disease complications and progression. Over the last fifteen years there has been a six-fold increase in the use of CT, which has lead to a growing concern in relation to cumulative radiation exposure. The challenge to the medical profession is to identify dose reduction strategies that meet acceptable image quality, but fulfil the requirements of a diagnostic quality CT. Dose-optimisation, particularly in CT, is essential as it reduces the chances of patients receiving cumulative radiation doses in excess of 100 mSv, a dose deemed significant by the United Nations Scientific Committee on the Effects of Atomic Radiation. This review article explores the current trends in imaging in CF with particular emphasis on new developments in dose optimisation

    Role of radiologic imaging in irritable bowel syndrome: evidence-based review

    Get PDF
    Purpose: To critically evaluate the current literature in an effort to establish the current role of radiologic imaging (computed tomography, magnetic resonance imaging, ultrasonography [US], fluoroscopy, conventional film radiography) in irritable bowel syndrome (IBS). Materials and Methods: The term “irritable bowel syndrome” was used to search Clinical Evidence, UpToDate, Cochrane Library, TRIP, and National Institute for Health and Clinical Excellence databases and the American College of Physicians Journal Club and Evidence-Based Medicine online. PubMed was searched by using medical subject headings (“irritable bowel syndrome;” “colonic diseases, functional;” “diagnosis;” “colonography;” “computed tomographic (CT)”) and the dates January 1, 1985 to July 1, 2010. Appraisal was independently performed by two reviewers who followed the Oxford Centre for Evidence Based Medicine practice criteria. Results: No systematic review (SR) specifically examined radiologic imaging in IBS; however, in the secondary literature, five relevant SRs or guidelines partially addressed this topic. A PubMed search identified 1451 articles, 111 of which at least partially addressed radiologic imaging. Of these, seven valid articles (two SRs and five primary research articles) were identified. The five primary research articles examined either colonic investigations (colonoscopy and barium enema examination) (n = 5) or US (n = 2) or both (n = 2). Structural disease found infrequently in patients with IBS-type symptoms included diverticulosis, colorectal cancer, celiac disease, inflammatory bowel disease, and ovarian cancer. The incidence of structural disease in patients with concerning symptoms was low. Conclusion: Although widely used, there is a surprising paucity of evidence guiding radiologic imaging in IBS. Radiologic imaging may not be required in patients with IBS without potentially concerning symptoms but should be considered where such symptoms exist, and choice of imaging study should be influenced by predominant symptoms. Definitive recommendations must await further research

    Pure iterative reconstruction improves image quality in computed tomography of the abdomen and pelvis acquired at substantially reduced radiation doses in patients with active Crohn disease

    Get PDF
    Objective: We assessed diagnostic accuracy and image quality of modified protocol (MP) computed tomography (CT) of the abdomen and pelvis reconstructed using pure iterative reconstruction (IR) in patients with Crohn disease (CD). Methods: Thirty-four consecutive patients with CD were referred with suspected extramural complications. Two contemporaneous CT datasets were acquired in all patients: standard protocol (SP) and MP. The MP and SP protocols were designed to impart radiation exposures of 10% to 20% and 80% to 90% of routine abdominopelvic CT, respectively. The MP images were reconstructed with model-based IR (MBIR) and adaptive statistical IR (ASIR). Results: The MP-CT and SP-CT dose length product were 88 (58) mGy.cm (1.27 [0.87] mSv) and 303 [204] mGy.cm (4.8 [2.99] mSv), respectively (P < 0.001). Median diagnostic acceptability, spatial resolution, and contrast resolution were significantly higher and subjective noise scores were significantly lower on SP-ASIR 40 compared with all MP datasets. There was perfect clinical agreement between MP-MBIR and SP-ASIR 40 images for detection of extramural complications. Conclusions: Modified protocol CT using pure IR is feasible for assessment of active CD

    Cumulative radiation exposure from diagnostic imaging in intensive care unit patients.

    Get PDF
    AIM: To quantify cumulative effective dose of intensive care unit (ICU) patients attributable to diagnostic imaging. METHODS: This was a prospective, interdisciplinary study conducted in the ICU of a large tertiary referral and level 1 trauma center. Demographic and clinical data including age, gender, date of ICU admission, primary reason for ICU admission, APACHE II score, length of stay, number of days intubated, date of death or discharge, and re-admission data was collected on all patients admitted over a 1-year period. The overall radiation exposure was quantified by the cumulative effective radiation dose (CED) in millisieverts (mSv) and calculated using reference effective doses published by the United Kingdom National Radiation Protection Board. Pediatric patients were selected for subgroup-analysis. RESULTS: A total of 2737 studies were performed in 421 patients. The total CED was 1704 mSv with a median CED of 1.5 mSv (IQR 0.04-6.6 mSv). Total CED in pediatric patients was 74.6 mSv with a median CED of 0.07 mSv (IQR 0.01-4.7 mSv). Chest radiography was the most commonly performed examination accounting for 83% of all studies but only 2.7% of total CED. Computed tomography (CT) accounted for 16% of all studies performed and contributed 97% of total CED. Trauma patients received a statistically significant higher dose [median CED 7.7 mSv (IQR 3.5-13.8 mSv)] than medical [median CED 1.4 mSv (IQR 0.05-5.4 mSv)] and surgical [median CED 1.6 mSv (IQR 0.04-7.5 mSv)] patients. Length of stay in ICU [OR = 1.12 (95%CI: 1.079-1.157)] was identified as an independent predictor of receiving a CED greater than 15 mSv. CONCLUSION: Trauma patients and patients with extended ICU admission times are at increased risk of higher CEDs. CED should be minimized where feasible, especially in young patients

    Low-dose carotid computed tomography angiography using pure iterative reconstruction

    Get PDF
    The aim of this study was to assess if a low-dose carotid computed tomography angiography (CTA) performed with pure iterative reconstruction (IR) is comparable to a conventional dose CTA protocol. Methods: Twenty patients were included. Radiation dose was divided into a low-dose acquisition reconstructed with pure IR and a conventional dose acquisition reconstructed with 40% hybrid IR. Dose, image noise, contrast resolution, spatial resolution, and carotid artery stenosis were measured. Results: Mean effective dose was significantly lower for low-dose than conventional dose studies (1.84 versus 3.71 mSv; P < 0.001). Subjective image noise, contrast resolution, and spatial resolution were significantly higher for the low-dose studies. There was excellent agreement for stenosis grading accuracy between low- and conventional dose studies (Cohen κ = 0.806). Conclusions: A low-dose carotid CTA protocol reconstructed with pure IR is comparable to a conventional dose CTA protocol in terms of image quality and diagnostic accuracy while enabling a dose reduction of 49.6%

    Feasibility of low-dose CT with model-based iterative image reconstruction in follow-up of patients with testicular cancer.

    Get PDF
    Purpose: We examine the performance of pure model-based iterative reconstruction with reduced-dose CT in follow-up of patients with early-stage testicular cancer. Methods: Sixteen patients (mean age 35.6 ± 7.4 years) with stage I or II testicular cancer underwent conventional dose (CD) and low-dose (LD) CT acquisition during CT surveillance. LD data was reconstructed with model-based iterative reconstruction (LD–MBIR). Datasets were objectively and subjectively analysed at 8 anatomical levels. Two blinded clinical reads were compared to gold-standard assessment for diagnostic accuracy. Results: Mean radiation dose reduction of 67.1% was recorded. Mean dose measurements for LD–MBIR were: thorax – 66 ± 11 mGy cm (DLP), 1.0 ± 0.2 mSv (ED), 2.0 ± 0.4 mGy (SSDE); abdominopelvic – 128 ± 38 mGy cm (DLP), 1.9 ± 0.6 mSv (ED), 3.0 ± 0.6 mGy (SSDE). Objective noise and signal-to-noise ratio values were comparable between the CD and LD–MBIR images. LD–MBIR images were superior (p < 0.001) with regard to subjective noise, streak artefact, 2-plane contrast resolution, 2-plane spatial resolution and diagnostic acceptability. All patients were correctly categorised as positive, indeterminate or negative for metastatic disease by 2 readers on LD–MBIR and CD datasets. Conclusions: MBIR facilitated a 67% reduction in radiation dose whilst producing images that were comparable or superior to conventional dose studies without loss of diagnostic utility

    The Back 2 Activity Trial: education and advice versus education and advice plus a structured walking programme for chronic low back pain

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Current evidence supports the use of exercise-based treatment for chronic low back pain that encourages the patient to assume an active role in their recovery. Walking has been shown it to be an acceptable type of exercise with a low risk of injury. However, it is not known whether structured physical activity programmes are any more effective than giving advice to remain active.</p> <p>Methods/Design</p> <p>The proposed study will test the feasibility of using a pedometer-driven walking programme, as an adjunct to a standard education and advice session in participants with chronic low back pain. Fifty adult participants will be recruited via a number of different sources. Baseline outcome measures including self reported function; objective physical activity levels; fear-avoidance beliefs and health-related quality of life will be recorded. Eligible participants will be randomly allocated under strict, double blind conditions to one of two treatments groups. Participants in group A will receive a single education and advice session with a physiotherapist based on the content of the 'Back Book'. Participants in group B will receive the same education and advice session. In addition, they will also receive a graded pedometer-driven walking programme prescribed by the physiotherapist. Follow up outcomes will be recorded by the same researcher, who will remain blinded to group allocation, at eight weeks and six months post randomisation. A qualitative exploration of participants' perception of walking will also be examined by use of focus groups at the end of the intervention. As a feasibility study, treatment effects will be represented by point estimates and confidence intervals. The assessment of participant satisfaction will be tabulated, as will adherence levels and any recorded difficulties or adverse events experienced by the participants or therapists. This information will be used to modify the planned interventions to be used in a larger randomised controlled trial.</p> <p>Discussion</p> <p>This paper describes the rationale and design of a study which will test the feasibility of using a structured, pedometer-driven walking programme in participants with chronic low back pain.</p> <p>Trial Registration</p> <p>[ISRCTN67030896]</p

    Quaternary Bat Diversity in the Dominican Republic

    No full text
    Velazco, Paúl M., O'Neill, Hannah, Gunnell, Gregg F., Cooke, Siobhán B., Rimoli, Renato, Rosenberger, Alfred L., Simmons, Nancy B. (2013): Quaternary Bat Diversity in the Dominican Republic. American Museum Novitates 2013 (3779): 1-20, DOI: 10.1206/3779.2, URL: http://www.bioone.org/doi/abs/10.1206/3779.
    corecore