11 research outputs found

    Correlation Between Microleakage And Screw Loosening At Implant-Abutment Connection

    No full text
    PURPOSE This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titaniuım) with different geometries were connected to its own implant fixture. All the abutments were tightened with a standard torque value then the composition was connected to the modified fluid filtration system. After the measurements of leakage removal torque values were re-measured. Kruskal-wallis test was performed for non-parametric and one-way ANOVA was performed for parametric data. The correlation was evaluated using Spearman Correlation Test (α=0.05). RESULTS Significantly higher microleakage was found at the connection of implant-internal hex zirconium abutment. Observed mean torque value loss was also significantly higher than other connection geometries. Spearman tests revealed a significant correlation between microleakage and screw loosening. CONCLUSION Microleakage may provoke screw loosening. Removing torque values rationally decrease with the increase of microleakage.PubMedWoSScopu

    Evaluation Of Low-Level Laser Therapy In Tmd Patients

    No full text
    Light amplification by stimulated emission of radiation (laser) is one of the most recent treatment modalities in dentistry. Low-level laser therapy (LLLT) is suggested to have biostimulating and analgesic effects through direct irradiation without causing thermal response. There are few studies that have investigated the efficacy of laser therapy in temporomandibular disorders (TMD), especially in reduced mouth opening. The case report here evaluates performance of LLLT with a diode laser for temporomandibular clicking and postoperative findings were evaluated in two cases of TMD patients. First patient had a history of limited mouth opening and pain in temporomandibular joint (TMJ) region since nine months. Second patient's main complaint was his restricted mouth opening, which was progressed in one year. LLLT was performed with a 685 nm red probed diode laser that has an energy density of 6.2 J/cm2, three times a week for one month, and application time was 30 seconds (685 nm, 25 mW, 30 s, 0.02 Hz, and 6.2 J/cm2) (BTL-2000, Portative Laser Therapy Device). The treatment protocol was decided according to the literature. One year later patients were evaluated and there were no changes. This application suggested that LLLT is an appropriate treatment for TMD related pain and limited mouth opening and should be considered as an alternative to other methods.PubMedScopu

    What Is The Changing Frequency Of Diamond Burs?

    No full text
    PURPOSE The purpose of this study was to determine the changing frequency of a diamond bur after multiple usages on 3 different surfaces. MATERIALS AND METHODS Human premolar teeth (N = 26), disc shaped direct metal laser sintered CoCr (N = 3) and zirconia specimens (N = 3) were used in this study. Groups named basically as Group T for teeth, Group M for CoCr, and Group Z for zirconia. Round tapered black-band diamond bur was used. The specimens were randomly divided into three groups and placed with a special assembly onto the surveyor. 1, 5, and 10 preparation protocols were performed to the first, second, and third sub-groups, respectively. The subgroups were named according to preparation numbers (1, 5, 10). The mentioned bur of each group was then used at another horizontal preparation on a new tooth sample. The same procedure was used for CoCr and zirconia disc specimens. All of the bur surfaces were evaluated using roughness analysis. Then, horizontal tooth preparation surfaces were examined under both stereomicroscope and SEM. The depth maps of tooth surfaces were also obtained from digital stereomicroscopic images. The results were statistically analyzed using One-Way ANOVA, and the Tukey HSD post-hoc tests (α=.05). RESULTS All of the groups were significantly different from the control group (P<.001). There was no significant difference between groups Z5 and Z10 (P=.928). Significant differences were found among groups T5, M5, and Z5 (P<.001). CONCLUSION Diamond burs wear after multiple use and they should be changed after 5 teeth preparations at most. A diamond bur should not be used for teeth preparation after try-in procedures of metal or zirconia substructures.PubMedWoSScopu

    Microscopic evaluation of the thickness and structure of the cement and cement-dentin interdiffusion zone after luting posts with three different luting cements

    No full text
    Clinical studies report that failures of fiber post cementation occur mainly at the cement-dentin interface. The aim of this in vitro study is to compare the scanning electron microscopic (SEM) evaluations of the cement thicknesses in the root canals and the thickness of cement-dentin interface zones obtained after luting standardized glass-fiber posts with three different types of luting cements. Thirty single-rooted mandibular premolars of similar sizes were prepared for post insertion after biomechanical preparation and obturation. They were divided into three groups containing 10 samples each. Standardized glass-fiber posts were cemented with zinc phosphate cement for ZNP group, with conventional adhesive resin cement for CAR group, and with self-adhesive resin cement for SAR group. The formation and thickness of cement and cement-dentin interface zone were evaluated by stereomicroscope and SEM using x800 magnification, and the data were analyzed. There was no significant difference between groups in terms of cement thickness (p=0.835); however, there were significant differences among the cement layer thicknesses measured at the three examined levels of the root canals (p=0.000). The groups using conventional adhesive resin cement presented longer micromechanical interlocking while the groups using self-adhesive resin cement showed wide gaps and zinc phosphate cement showed no bonding between cement-dentin interdiffusion zones along the root canal. As a clinical consequence, the use of zinc phosphate cement may not provide strong bond between dentin-cement interface. Conventional adhesive resin cements showed reliable bond to dentin when compared to zinc phosphate and self-adhesive resin cement

    Combined Treatment with Laser Sintering and Zirconium: A Case Report of Dentinogenesis Imperfecta

    Get PDF
    Osteogenesis imperfecta (OI) is a heterogeneous disorder of connective tissue that manifests mainly as skeletal deformity and bone fragility. Dentinogenesis imperfecta (DI) is sometimes an accompanying symptom of OI. The treatment protocol of these patients varies according to the clinical appearance. The case report here describes complete mouth rehabilitation of an 18-year-old male patient with OI and DI using direct metal laser sintering (DMLS) technique of metal-ceramic restorations and zirconium all-ceramic crowns. DMLS is an additive metal fabrication technology that is simpler, more precise, and healthier than conventional manufacturing and can be remarkably cost effective. Moreover, the technique affords highly accurate production of fixed partial dentures with ideal marginal fit and excellent mechanical properties. The patient was treated using a multidisciplinary strategy that focused on controlling caries, protecting teeth from further wear, obtaining an appropriate vertical dimension, and providing soft tissue support to return the facial profile to a normal appearance using new technology in the field of prosthetics

    The effect of MDP-based primer on shear bond strength of various cements to two different ceramic materials

    No full text
    The aim of this study was to determine the effect of 10-metha cryloyloxydecyl dihydrogen phosphate (MDP)-based primer on the shear bond strengths of thermally aged self-adhesive and conventional adhesive resin cements and zinc phosphate cement to zirconia and lithium disilicate substructures. Sixty zirconia (Z) and 60 lithium disilicate (L) disk specimens were cut from ceramic blocks. Each group was divided into six subgroups (n = 10). Half of the specimens of each ceramic group were treated with primer (P) and the other half was remained untreated. Three types of cement were applied: zinc phosphate cement [(ZPC) (Hoffmann Harmonic Shades)]; self-adhesive resin cement [(SAC) (RelyX U200)]; conventional adhesive resin cement [(CAC) (C&B)]. The specimens were subjected to thermal aging procedure for 1 week under 37 degrees C water bath. Shear bond strength (SBS) was determined using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with three-way (ANOVA). Pairwise comparisons and interactions between groups were analyzed by using Tukey's simultaneous confidence intervals. There was no significant difference between the SBS values of SAC-Z (11,47 +/- 0,47) and SAC-ZP (11,39 +/- 0,42) (p > 0.05). However, the SBS values of SAC-L (12.34 +/- 0,55) and SAC-LP (12,50 +/- 0,49) were significantly higher than those of SAC-Z and SAC-ZP (p < 0.00). The use of primer significantly increased the SBS value of CAC-ZP (8,05 +/- 0,55) when compared to the SBS value of CAC-Z (3,53 +/- 0,41) (p < 0.00). Resin cement that contains methacrylate monomers with phosphoric ester functional groups exhibited reliable bond to zirconia. However, the use of an MDP-based primer may not further improve its bond strength
    corecore