    Sterilization of single-use helical stone baskets: an experimental study

    No full text
    ABSTRACT Objectives: To experimentally evaluate the efficacy of a standard sterilization protocol employed during reuse of disposable helical stone baskets. Methods: Study performed on 20 helical stone baskets: 10 were used in the initial validation process, contaminated with Escherichia coli ATCC 25922 and imprinted on Müeller-Hinton media; 10 catheters were contaminated with Geobacillus stearothermophilus ATCC 7953, processed, inoculated in TSB and incubated in a water bath at a temperature of 55°C. Bacterial growth was evaluated after 1, 3, 5 and 7 days. After sterilization, stone baskets were also opened and closed 40 times to check for functional problems. All plastic and basket parts were carefully checked for damages. Results: After the 72-hour incubation period, there was growth of E. coli ATCC 25922 in 100% of imprints. After the sterilization process and up to 7 days incubation period on a blood agar plate, there was no growth of G. stearothermophilus ATCC 7953 or any other bacteria. There were no functional problems or damage to baskets after the sterilization process. Conclusion: The ethylene oxide system is efficacious and safe for sterilization of disposable helical stone baskets. However, further clinical studies are required and should provide more safety information

    Microbiological evaluation of the steam sterilization of assembled laparoscopic instruments

    No full text
    ABSTRACT Objective: assess the safety of steam sterilization of assembled laparoscopic instruments with challenge contamination. Method: a laboratory experimental study, using as test samples trocars and laparoscopic graspers. Geobacillus stearothermophillus ATCC-7953 was used, with a microbial population of 106UFC/Filter paper substrate, removed from the biological indicator. Three of them were introduced into each instrument at the time of assembly, and sterilized at pressurized saturated steam, 134oC for 5 minutes. After sterilization, the instrument was disassembled and each filter paper substrate was inoculated in soybean casein culture and incubated at 56oC for 21 days. In case of absence of growth, they were subjected to heat shock of 80oC, for 20 minutes and re-incubated for 72 hours. Sample size: 185 graspers and 185 trocars, with 95% power. We paired the experiments with comparative negative control groups (5 graspers and 5 trocars with challenge contamination, sterilized disassembled) and positive control (30 filter paper supports, unsterilized), subject to the same incubation procedures. Results: there was no microbial growth in experimental and negative control. The results of the positive control were satisfactory. Conclusion: this study provided strong scientific evidence to support the safety of steam sterilizing of the assembled laparoscopic instrument

    Microbial diagnosis of infection and colonization of cardiac implantable electronic devices by use of sonication

    No full text
    Objectives: The clinical utility of sonication as an adjunctive diagnostic tool for the microbial diagnosis of cardiac implantable device-associated infections (CIDAIs) was investigated. Methods: The implants of 83 subjects were investigated, 15 with a CIDAI and 68 without a clinical infection. Clinical data were analyzed prospectively and sonication fluid cultures (83 patients, 100%) and traditional cultures (31 patients, 37.4%) were performed Results: Generator pocket infection and device-related endocarditis were found in 13 (86.7%) and four (26.7%) subjects, respectively. The mean numbers of previous technical complications and infections were higher in the infected patients compared to the non-infected patients (8 vs. 1, p < 0.001; 2 vs. 0, p < 0.031, respectively). The sensitivity and specificity for detecting CIDAI was 73.3% (11/15) and 48.5% (33/68) for sonication fluid culture, and 26.7% (4/15) and 100% (16/16) for traditional culture (p < 0.001), respectively. A higher number of organisms were identified by sonication fluid than by tissue culture (58 vs. 4 specimens; p < 0.001). The most frequent organisms cultured were Gram-positive cocci (66.1%), mainly coagulase-negative staphylococci (35.5%). Thirty-five (51.5%) non-infected subjects were considered colonized due to the positive identification of organisms exclusively through sonication fluid culture. Conclusions: Sonication fluid culture from the removed cardiac implants has the potential to improve the microbiological diagnosis of CIDAIs

    Microbial investigation of biofilms recovered from endotracheal tubes using sonication in intensive care unit pediatric patients

    Get PDF
    Objectives: To compare cultured microorganisms identified on endotracheal tubes biofilms through sonication technique with traditional tracheal aspirate collected at extubation of pediatric intensive care unit patients. Methods: Demographic and epidemiological data were analyzed to identify factors possibly related with the microbiological profile of the two collection methods. Associations between categorical and continuous variables were analyzed using the chi-square or Fisher's exact test, or Student's t test. p-Value <0.05 were considered significant. Results: Thirty endotracheal tubes and tracheal aspirates samples from 27 subjects were analyzed. Only one patient presented the clinical diagnosis of ventilator-associated pneumonia. Overall, 50% of bacteria were Gram-negative bacilli, followed by Gram-positive bacteria in 37%, and fungi in 10%. No statistically significant difference on the distribution of Gram-positive or Gram-negative bacteria (p = 0.996), and fungi (p = 0.985) were observed between the collection methods. Pseudomonas spp. was the most frequent microorganism identified (23.8%), followed by Streptococcus spp. (18.5%), Acinetobacter spp. (15.9%), coagulase-negative staphylococci (11.2%), and Klebsiella spp. (8.6%). Concordant results between methods amounted to 83.3%. Pseudomonas aeruginosa and Acinetobacter baumannii showed carbapenem resistance in 50% and 43.7% of the isolates, respectively. In general, cultures after endotracheal tubes sonication (non-centrifuged sonication fluid and centrifuged sonication fluid) yielded bacteria with higher rates of antimicrobial resistance compared to tracheal aspirates cultures. Additionally, in 12 subjects (40%), we observed discrepancies regarding microbiologic profiles of cultures performed using the collection methods. Conclusions: Our study demonstrated that sonication technique can be applied to ET biofilms to identify microorganisms attached to their surface with a great variety of species identified. However, we did not find significant differences in comparison with the traditional tracheal aspirate culture approach. Keywords: Sonication, Endotracheal tube, Biofilm, Tracheal aspirat

    Evaluation of aflibercept and ziv-aflibercept binding affinity to vascular endothelial growth factor, stability and sterility after compounding

    No full text
    Abstract Purpose To investigate the binding affinity, stability, and sterility of aflibercept and ziv-aflibercept to vascular endothelial growth factor (Holash et al. in Proc Natl Acad Sci USA 99(17):11393–11398, 2002. https://doi.org/10.1073/pnas.172398299) after compounding and storage for up to 28 days at 4 °C and − 8 °C. Methods Tuberculin-type 1-mL syringes were prepared containing aflibercept (40 mg/mL) and ziv-aflibercept (25 mg/mL). Samples were stored at 4 °C and − 8 °C for 0, 14, and 28 days and evaluated for the binding affinity of anti-VEGF to VEGF and stability using enzyme-linked immunosorbent assays. The evaluation of sample sterility was performed. Results Laboratory trials with aflibercept and ziv-aflibercept showed preservation of the drug-binding capability to recombinant VEGF when stored in plastic syringes for up to 28 days at 4 °C and − 8 °C. No significant decrease in mass or concentration were observed. Microbiologic evaluations did not detect contamination in the syringes. Conclusions The current study corroborates that compounded anti-VEGF drugs aflibercept and ziv-aflibercept do not loose stability or binding affinity and do not become contaminated if prepared under sterile conditions and stored at 4 °C or − 8 °C for 14 or 28 days