33 research outputs found
Decabromodiphenylether trends in the European environment: bird eggs, sewage sludge and surficial sediments
Concern on relatively high levels and the potential bioaccumulation of decabromodiphenylether (BDE209) has led to a European 8-year monitoring program on trends in BDE209 concentrations in birds, sewage sludge and sediments from seven countries. BDE209 was analysed in four environmental matrices: sparrowhawk eggs (UK), glaucous gull eggs (Bear Island, Norway), sewage sludge (UK, Ireland and the Netherlands) and sediment (France, Germany, the Netherlands, UK and Ireland). BDE209 was detected in most of the glaucous gull and sparrow hawk eggs but neither increasing nor decreasing trends in these BDE209 levels were observed. An indication for debromination of BDE209 in sparrowhawk eggs was found. BDE209 concentrations in sediments ranged from very low ng/g (88 ng/g on an organic carbon (OC) basis) concentrations, in the rivers Elbe, Ems, Seine and the Outer Humber, to high μg/g (120 μg/g OC), in the Western Scheldt, Liverpool Bay and River Mersey. Apart from decreasing values in the Western Scheldt sediment no further decreases in BDE209 concentrations were observed over time, neither in sediment nor in sewage sludge showing that the voluntary emissions control program of the bromine industry only had a local effect. In contrast to the sewage sludge samples from the Netherlands (mean 355 ng/g dry weight (dw) or 1026 ng/g OC), the BDE209 concentrations in the UK increased at all sites from 2006 to 2011 (8092 ng/g dw or 22,367 ng/g OC). The BDE209 levels in several UK sediments and sewage sludge were still very high at the end of the program in 2012, most likely caused by frequent use of BDE209 in the textile industry. This may be indicative of the persistence of BDE209 and the limited degradation into lower brominated congeners in sediment, although it cannot be excluded that ongoing BDE209 emissions have played a role as well
Determination of ultra-trace levels of priority PBDEs in water samples by isotope dilution GC(ECNI)MS using 81Br-labelled standards.
A gas chromatography electron capture negative ionization mass spectrometry (GC(ECNI)MS) procedure for the determination of priority polybrominated diphenyl ethers (PBDEs; congeners 28, 47, 99, 100, 153 and 154) in water samples at regulatory EU levels has been developed. The method is based on the use o
A new class of contaminants of concern? A comprehensive review of liquid crystal monomers
Liquid crystal monomers (LCMs) are a class of emerging contaminants of concern predicted to be persistent, bioaccumulative and toxic (PBT). Being one of the key components in liquid crystal displays (LCDs), the disposal of LCD containing devices is closely related to the emission of LCMs into the environment. LCMs have been detected in a wide range of environmental matrices including dust, sediment, soil, sewage leachate, and air, with concentration ranges between 17 and 2121 ng/g found in indoor residential dust. Furthermore, they have been detected on human skin at concentrations up to 2,071,000 ng/m2 and in the serum of e-waste dismantling workers, at concentrations ranging from 3.9 to 276 ng/mL. Despite the far-reaching contamination of these compounds, there is limited knowledge of their environmental behaviour, fate, and toxicity. Model predictions show that 297 of 330 LCMs are persistent and bioaccumulative compounds, with many more indicated as being toxic. However, current knowledge of their physicochemical and PBT properties is largely restricted to theoretical predictions and limited to a small number of experimental toxicity studies. As an emerging class of contaminants of concern, a lack of standardisation between studies was identified as a key challenge to advancing the state of knowledge of these compounds. Not only are harmonised analytical methods for their determination and quantification in environmental media yet to be established, but there is also a need for a universal abbreviation system. To further harmonise the reporting of data on LCMs we propose reporting the sum concentration of ten priority LCMs, selected on the basis detection frequency, toxicity and potential for human exposure. Of the ten priority LCMs five are fluorinated biphenyls and analogues, four are biphenyls/bicyclohexyls and analogues and one is a cyanobiphenyl.</p
A Rapid Screening Method for the Detection of Additives in Electronics and Plastic Consumer Products Using AP-MALDI-qTOF-MS
A novel method was developed and optimized for the fast-screening analysis of additives in electronics and plastic consumer products using atmospheric pressure matrix-assisted laser desorption ionization (AP-MALDI) coupled with a high-resolution quadrupole time-of-flight (qTOF) mass spectrometer (MS). To simplify sample preparation and increase sample throughput, an innovative 48 well graphene nanoplatelets (GNP) doped AP-MALDI target plate was developed. The GNP incorporated in the target plate fulfilled the role of the MALDI matrix and, therefore, sample extracts could be directly transferred to the AP-MALDI 48 well target plate and analyzed without a subsequent matrix addition. The homogeneously dispersed and immobilized GNP target plates also provided increased signal intensity and reproducibility. Furthermore, analytical standards of various plastic additives and plastic products with known concentrations of additives were studied to assess the AP-MALDI ionization mechanisms and method capability. The analysis time was 15 s per measurement using an automated sequence. The GNP-doped target plates exhibited high desorption/ionization of low molecular weight molecules (<1000 Da) and can be used in both positive and negative ionization modes. The AP-MALDI-qTOF-MS method was applied to screen for additives in various electronics and plastic consumer products. Suspect screening was performed using a database containing 1366 compounds. A total of 56 additives including antioxidants, flame retardants, plasticizers, UV-stabilizers, and UV-filters were identified (confidence level 4). Identification of certain plastic additives in plastic children’s toys may indicate that they are recycled from waste electronic and electronic equipment (WEEE)
Chlorinated paraffins and tris (1-chloro-2-propyl) phosphate in spray polyurethane foams – A source for indoor exposure?
In this study, we investigated chemical additives present in new and used spray polyurethane foams (SPFs) and assessed the dermal transfer through direct contact. This first study shows that cured do-it-yourself spray one-component SPFs (OCFs) often contain chlorinated paraffins (C14-C37), and tris (1-chloro-2-propyl) phosphate (TCIPP), ranging 0.2–50%, and 0.9–30% w/w, respectively. Six OCFs contained CP levels ranging 22–50% w/w, whereas nine OCFs used for similar applications only contained CP levels ranging 2–17% w/w. It is unclear if the combination CPs/TCIPP is meant to improve the flame retardancy of products, and could suggest an unnecessary use of high CPs/TCIPP concentrations in OCFs. The two-component SPFs (TCFs) contained only TCIPP with levels ranging from 7.0% to 9.0%. The CPs and TCIPP were easily transferred from cured OCFs to the hands. Levels up to 590 µg per hand for CPs and up to 2.7 µg per hand for TCIPP were found. After end-of-life, it is challenging to recycle used SPFs. They may, therefore, end up at landfills where the TCIPP/CPs may leach into the environment. Therefore, further investigation is needed to assess potential exposure risks associated with general and occupational use, and the impact of landfill leaching on the environment
A Rapid Screening Method for the Detection of Additives in Electronics and Plastic Consumer Products Using AP-MALDI-qTOF-MS
A novel method was developed and optimized for the fast-screening analysis of additives in electronics and plastic consumer products using atmospheric pressure matrix-assisted laser desorption ionization (AP-MALDI) coupled with a high-resolution quadrupole time-of-flight (qTOF) mass spectrometer (MS). To simplify sample preparation and increase sample throughput, an innovative 48 well graphene nanoplatelets (GNP) doped AP-MALDI target plate was developed. The GNP incorporated in the target plate fulfilled the role of the MALDI matrix and, therefore, sample extracts could be directly transferred to the AP-MALDI 48 well target plate and analyzed without a subsequent matrix addition. The homogeneously dispersed and immobilized GNP target plates also provided increased signal intensity and reproducibility. Furthermore, analytical standards of various plastic additives and plastic products with known concentrations of additives were studied to assess the AP-MALDI ionization mechanisms and method capability. The analysis time was 15 s per measurement using an automated sequence. The GNP-doped target plates exhibited high desorption/ionization of low molecular weight molecules (<1000 Da) and can be used in both positive and negative ionization modes. The AP-MALDI-qTOF-MS method was applied to screen for additives in various electronics and plastic consumer products. Suspect screening was performed using a database containing 1366 compounds. A total of 56 additives including antioxidants, flame retardants, plasticizers, UV-stabilizers, and UV-filters were identified (confidence level 4). Identification of certain plastic additives in plastic children’s toys may indicate that they are recycled from waste electronic and electronic equipment (WEEE)
Migration of hazardous contaminants from WEEE contaminated polymeric toy material by mouthing
This study evaluated the migration of brominated flame retardants (BFRs), phosphate flame retardants (PFRs), bisphenols (BPA, BPF), and phthalate ester-based plasticizers from recycled polymeric toy material, containing waste electrical and electronic equipment (WEEE), in artificial saliva simulating 1 h of mouthing. In total 12 parts of 9 different toys were tested in triplicate after confirming WEEE specific contamination. Up to 11 contaminants were detected in saliva from one toy sample. The highest migration rate up to 128 ng/(cm2 x h) was found for BPA followed by bis(2-ethylhexyl) phthalate (DEHP) and diisobutyl phthalate (DIBP) with migration rates up to 25.5 and 8.27 ng/(cm2 x h), respectively. In addition to DecaBDE, which was detected in 3 saliva samples at migration rates between 0.09 and 0.31 ng/(cm2 x h), the decaBDE replacements 2,4,6-tris(2,4,6-tribromophenoxy)-1,3,5-triazine (TTBP-TAZ), decabromodiphenyl ethane (DBDPE), resorcinol bis(diphenyl phosphate) (RDP), and hexabromocyclododecane (HBCDD) were detected as well with comparable migration rates. 2,4,6-tribromphenol (246-TBP) reached migration rates up to 1.15 ng/(cm2 x h) in correspondence to the presence of TTBP-TAZ. Tetrabromobisphenol A (TBBPA), BPA, 246-TBP, DEHP, DIBP and triphenyl phosphate (TPHP) were predominantly observed in saliva with a detection frequency between 50 and 75%. Daily intake (DI) values were calculated for relevant analytes and compared to tolerable daily intake (TDI) values. The highest DI values of 72.4, 14.3, 5.74, 2.28 and 2.09 ng/(kg BW x day), were obtained for BPA, DEHP, DIBP, TBBPA, and TPHP, respectively. None of them exceed the TDI value or respective reference dose (RfD)
Optimization of a low flow sampler for improved assessment of gas and particle bound exposure to chlorinated paraffins
An optimized low volume sampler was developed to determine both gas- and particle bound concentrations of short and medium-chain chlorinated paraffins (S/MCCPs). Background contamination was limited by the sampler design, providing method quantification limits (MQLs) at least two orders of magnitude lower than other studies within the gas (MQL: 500 pg (ΣSCCPs), 1.86 ng (ΣMCCPs)) and particle (MQL: 500 pg (ΣSCCPs), 1.72 ng (ΣMCCPs) phases. Good repeatability was observed between parallel indoor measurements (RSD ≤ 9.3% (gas), RSD ≤ 14% (particle)) with no breakthrough/saturation observed after a week of continuous sampling. For indoor air sampling, SCCPs were dominant within the gas phase (17 ± 4.9 ng/m3) compared to MCCPs (2.7 ± 0.8 ng/m3) while the opposite was observed in the particle bound fraction (0.28 ± 0.11 ng/m3 (ΣSCCPs) vs. 2.7 ± 1.0 ng/m3 (ΣMCCPs)). Only SCCPs in the gas phase could be detected reliably during outdoor sampling and were considerably lower compared to indoor concentrations (0.27 ± 0.10 ng/m3). Separation of the gas and particle bound phase was found to be crucial in applying the appropriate response factors for quantification based on the deconvoluted S/MCCP sample profile, thus avoiding over- (gas phase) or underestimation (particle phase) of reported concentrations. Very short chain chlorinated paraffins (vSCCPs, C5-C9) were also detected at equal or higher abundance compared to SCCP congener groups (C10-C13) congener groups, indicating an additional human indoor inhalation risk
Optimization of a low flow sampler for improved assessment of gas and particle bound exposure to chlorinated paraffins
An optimized low volume sampler was developed to determine both gas- and particle bound concentrations of short and medium-chain chlorinated paraffins (S/MCCPs). Background contamination was limited by the sampler design, providing method quantification limits (MQLs) at least two orders of magnitude lower than other studies within the gas (MQL: 500 pg (ΣSCCPs), 1.86 ng (ΣMCCPs)) and particle (MQL: 500 pg (ΣSCCPs), 1.72 ng (ΣMCCPs) phases. Good repeatability was observed between parallel indoor measurements (RSD ≤ 9.3% (gas), RSD ≤ 14% (particle)) with no breakthrough/saturation observed after a week of continuous sampling. For indoor air sampling, SCCPs were dominant within the gas phase (17 ± 4.9 ng/m3) compared to MCCPs (2.7 ± 0.8 ng/m3) while the opposite was observed in the particle bound fraction (0.28 ± 0.11 ng/m3 (ΣSCCPs) vs. 2.7 ± 1.0 ng/m3 (ΣMCCPs)). Only SCCPs in the gas phase could be detected reliably during outdoor sampling and were considerably lower compared to indoor concentrations (0.27 ± 0.10 ng/m3). Separation of the gas and particle bound phase was found to be crucial in applying the appropriate response factors for quantification based on the deconvoluted S/MCCP sample profile, thus avoiding over- (gas phase) or underestimation (particle phase) of reported concentrations. Very short chain chlorinated paraffins (vSCCPs, C5-C9) were also detected at equal or higher abundance compared to SCCP congener groups (C10-C13) congener groups, indicating an additional human indoor inhalation risk