Eksperymentalne badania drewnianych łuków
This paper presents the findings of the pilot studies of two-hinged wooden arches.
The prototype models of wooden arches with the span of 6m and the rise of 1m
were designed. The models had a rectangular cross-section of 180x40mm and
a T-section of 180x40mm with a plywood plate with the thickness of 6 mm and the
width of 500mm. The main objective of the T-section was to ensure the stability of
the arch. Each arch was composed of six segments – boards joined by clamping
plates. The bowstring truss including two inclined tie bars enables carrying asymmetric
loads and provides in-plane stability of the arch. A methodology for laboratory
testing of the prototype models of wooden arches subjected to different types
of loads was developed. Two prototypes of wooden arches were tested with rectangular
cross-sections and two T-section ones subjected to the loading across the
span, and two prototypes subjected to the half-span loading. In total, eight arches
were tested. Deflections of arches, cross-section deformations and arch thrust force
were recorded. The arches were tested until failure. The results of testing revealed
insufficient stability of the arches with rectangular cross-section in the horizontal
plane. For the arches with T-section the whole arch rib was damaged, the in-plane
stability was ensured by the T-section. The collapsing force of the T-section arch
was about 1.3times greater than the collapsing force of the rectangular section
arches.W niniejszym artykule przedstawiono wyniki eksperymentalnych badań dwuprzegubowych
drewnianych łuków. Skonstruowano badawcze modele drewnianych łuków o rozpiętości 6 m
i strzałce 1 m. Modele do badań miały przekrój prostokątny o wymiarach 180x40 mm oraz przekrój
teowy ze środnikiem 180x40mm i półką ze sklejki o grubości 6 mm i szerokości 500 mm.
Głównym zadaniem przekroju teowego było zabezpieczenie stabilności łuku. Każdy łuk składał
się z sześciu elementów – desek, które były połączone między sobą za pomocą płytek kolczastych.
W łuku było poziome stężenie z kabla dla przeniesienia sił poziomych od rozporu konstrukcji oraz
dwóch pochyłych stężeń z kabli dla przeniesienia niesymetrycznych obciążeń i zabezpieczenia
stabilności w płaszczyźnie łuku. Opracowano metodę badania eksperymentalnych wzorców drewnianych
łuków w warunkach laboratoryjnych na działanie różnych rodzajów obciążeń. Wypróbowano
po 2 badawcze wzorce drewnianych łuków o przekroju prostokątnym i przekroju teowym na
działanie obciążenia na całej rozpiętości, a także po 2 badawcze wzorce przy działaniu obciążenia
na połowie rozpiętości. W sumie zbadano 8 łuków. W trakcie eksperymentu były odczytywane
ugięcia łuku, odkształcenia w przekrojach poprzecznych oraz naprężenia rozciągające w stężeniach.
Łuki były badane do całkowitego zniszczenia. W wyniku badań łuków o przekroju prostokątnym
ustalono ich niedostateczną stabilność w poziomej płaszczyźnie. Łuki o przekroju teowym
niszczyły się w przekroju łuku, ich stabilność z płaszczyzny była zabezpieczona przekrojem teowym.
Niszczące obciążenia w łukach o przekroju teowym średnio były 1,3 razy większe od niszczących
obciążeń łuków o przekroju prostokątnym
EXPERIMENTAL RESEARCH OF WOODENARCHES
This paper presents the findings of the pilot studies of two-hinged wooden arches.
The prototype models of wooden arches with the span of 6m and the rise of 1m
were designed. The models had a rectangular cross-section of 180x40mm and
a T-section of 180x40mm with a plywood plate with the thickness of 6 mm and the
width of 500mm. The main objective of the T-section was to ensure the stability of
the arch. Each arch was composed of six segments – boards joined by clamping
plates. The bowstring truss including two inclined tie bars enables carrying asymmetric
loads and provides in-plane stability of the arch. A methodology for laboratory
testing of the prototype models of wooden arches subjected to different types
of loads was developed. Two prototypes of wooden arches were tested with rectangular
cross-sections and two T-section ones subjected to the loading across the
span, and two prototypes subjected to the half-span loading. In total, eight arches
were tested. Deflections of arches, cross-section deformations and arch thrust force
were recorded. The arches were tested until failure. The results of testing revealed
insufficient stability of the arches with rectangular cross-section in the horizontal
plane. For the arches with T-section the whole arch rib was damaged, the in-plane
stability was ensured by the T-section. The collapsing force of the T-section arch
was about 1.3times greater than the collapsing force of the rectangular section
arches.W niniejszym artykule przedstawiono wyniki eksperymentalnych badań dwuprzegubowych
drewnianych łuków. Skonstruowano badawcze modele drewnianych łuków o rozpiętości 6 m
i strzałce 1 m. Modele do badań miały przekrój prostokątny o wymiarach 180x40 mm oraz przekrój
teowy ze środnikiem 180x40mm i półką ze sklejki o grubości 6 mm i szerokości 500 mm.
Głównym zadaniem przekroju teowego było zabezpieczenie stabilności łuku. Każdy łuk składał
się z sześciu elementów – desek, które były połączone między sobą za pomocą płytek kolczastych.
W łuku było poziome stężenie z kabla dla przeniesienia sił poziomych od rozporu konstrukcji oraz
dwóch pochyłych stężeń z kabli dla przeniesienia niesymetrycznych obciążeń i zabezpieczenia
stabilności w płaszczyźnie łuku. Opracowano metodę badania eksperymentalnych wzorców drewnianych
łuków w warunkach laboratoryjnych na działanie różnych rodzajów obciążeń. Wypróbowano
po 2 badawcze wzorce drewnianych łuków o przekroju prostokątnym i przekroju teowym na
działanie obciążenia na całej rozpiętości, a także po 2 badawcze wzorce przy działaniu obciążenia
na połowie rozpiętości. W sumie zbadano 8 łuków. W trakcie eksperymentu były odczytywane
ugięcia łuku, odkształcenia w przekrojach poprzecznych oraz naprężenia rozciągające w stężeniach.
Łuki były badane do całkowitego zniszczenia. W wyniku badań łuków o przekroju prostokątnym
ustalono ich niedostateczną stabilność w poziomej płaszczyźnie. Łuki o przekroju teowym
niszczyły się w przekroju łuku, ich stabilność z płaszczyzny była zabezpieczona przekrojem teowym.
Niszczące obciążenia w łukach o przekroju teowym średnio były 1,3 razy większe od niszczących
obciążeń łuków o przekroju prostokątnym
МЕТОДИКА ЕКСПЕРИМЕНТАЛЬНИХ ДОСЛІДЖЕНЬ ДОЩАТИХ АРОК ЗІ З’ЄДНАННЯМ ОКРЕМИХ ДЕРЕВ’ЯНИХ ЕЛЕМЕНТІВ МЕТАЛОЗУБЧАТИМИ ПЛАСТИНАМИ
Наведено методику експериментальних досліджень роботи дощатих арок зі з’єднанням окремих дерев’яних елементів металозубчатими пластинами
Nucleotide-dependent farnesyl switch orchestrates polymerization and membrane binding of human guanylate-binding protein 1
Dynamin-like proteins (DLPs) mediate various membrane fusion and fission processes within the cell, which often require the polymerization of DLPs. An IFN-inducible family of DLPs, the guanylate-binding proteins (GBPs), is involved in antimicrobial and antiviral responses within the cell. Human guanylate-binding protein 1 (hGBP1), the founding member of GBPs, is also engaged in the regulation of cell adhesion and migration. Here, we show how the GTPase cycle of farnesylated hGBP1 (hGBP1F) regulates its self-assembly and membrane interaction. Using vesicles of various sizes as a lipid bilayer model, we show GTP-dependent membrane binding of hGBP1F. In addition, we demonstrate nucleotide-dependent tethering ability of hGBP1F. Furthermore, we report nucleotide-dependent polymerization of hGBP1F, which competes with membrane binding of the protein. Our results show that hGBP1F acts as a nucleotide-controlled molecular switch by modulating the accessibility of its farnesyl moiety, which does not require any supportive proteins