701 research outputs found

    An extended two-target differential game model for medium-range air combat game analysis

    Get PDF
    The first phase of an investigation of a two-target game, representing an air combat with boresight limited all-aspect guided missiles is summarized. The results, obtained by using a line of sight coordinate system, are compared to a similar recently published work. The comparison indicates that improved insight, gained by using line of sight coordinates, allows to discover important new features of the game solution

    Validation of zero-order feedback strategies for medium range air-to-air interception in a horizontal plane

    Get PDF
    A zero order feedback solution of a variable speed interception game between two aircraft in the horizontal plane, obtained by using the method of forced singular perturbation (FSP), is compared with the exact open loop solution. The comparison indicates that for initial distances of separation larger than eight turning radii of the evader, the accuracy of the feedback approximation is better than one percent. The result validates the zero order FSP approximation for medium range air combat analysis

    Photoexcitation spectroscopy of polythiophene

    Get PDF
    Journal ArticleRadiative recombination in polythiophene is studied by cw photoluminescence and photoinduced absorption spectroscopies and by photoluminescence-detected magnetic resonance. The fast-recombination centers are assigned to intrachain excitons in defect-free chains, while the slow recombination is due to intrachain excitons bound to spin- 1/2 defects

    Integrated organic light-emitting device/fluorescence-based chemical sensors

    Full text link
    A fluorescent chemical sensor platform, integrating an organic light-emitting device (OLED) light-source with a fluorescent probe, is demonstrated for a subsecond-fast oxygen sensor. The integration results in strong light coupling and negligible heating of the sensor film or analyte. The potential in vivo operation of compact, stand-alone, battery-powered, OLED-based miniaturized sensor arrays for chemical and biological applications is discussed. © 2002 American Institute of Physics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/69695/2/APPLAB-81-24-4652-1.pd

    Tunable perovskite-based photodetectors in optical sensing

    Get PDF
    Broad- and narrow-band, tunable perovskite photodetectors (PPDs) with size-dependent fast response times are demonstrated for the first time in optical sensing of analytes, including gas-phase and dissolved oxygen (DO), as well as glucose. The sensors included a LED excitation source and a polystyrene film with embedded oxygen-sensitive dyes, PtOEP or PdOEP. The analyte's dose-dependent photoluminescence (PL) intensity I and decay time τ were measured. Using the PPDs enabled monitoring gas-phase O2 at levels of 0 %–100 % with a sensitivity comparable to that of a Si photodiode. A broad dynamic range was similarly observed for DO monitoring and the limit of detection for glucose monitoring was ∌0.02 mM at an initial level of ∌0.26 mM DO. Importantly, the size-dependent fast response time of the PPDs enabled analyte monitoring via the preferred measurement of τ, rather than I, over a broad dynamic range, which was unattainable with organic photodetectors. The use of the narrow-band PPDs eliminated the need for optical filters, which leads to more compact device designs

    Electronic Structure of Lanthanum Hydrides with Switchable Optical Properties

    Full text link
    Recent dramatic changes in the optical properties of LaH_{2+x} and YH_{2+x} films discovered by Huiberts et al. suggest their electronic structure is described best by a local model. Electron correlation is important in H^- -centers and in explaining the transparent insulating behavior of LaH_3. The metal-insulator transition at x∌0.8x\sim 0.8 takes place in a band of highly localized states centered on the HH-vacancies in the LaH_3 structure.Comment: plain tex, 3 figure

    Practice characteristics of Emergency Department extracorporeal cardiopulmonary resuscitation (eCPR) programs in the United States: The current state of the art of Emergency Department extracorporeal membrane oxygenation (ED ECMO).

    Get PDF
    PURPOSE: To characterize the current scope and practices of centers performing extracorporeal cardiopulmonary resuscitation (eCPR) on the undifferentiated patient with cardiac arrest in the emergency department. METHODS: We contacted all US centers in January 2016 that had submitted adult eCPR cases to the Extracorporeal Life Support Organization (ELSO) registry and surveyed them, querying for programs that had performed eCPR in the Emergency Department (ED ECMO). Our objective was to characterize the following domains of ED ECMO practice: program characteristics, patient selection, devices and techniques, and personnel. RESULTS: Among 99 centers queried, 70 responded. Among these, 36 centers performed ED ECMO. Nearly 93% of programs are based at academic/teaching hospitals. 65% of programs are less than 5 years old, and 60% of programs perform ≀3 cases per year. Most programs (90%) had inpatient eCPR or salvage ECMO programs prior to starting ED ECMO programs. The majority of programs do not have formal inclusion and exclusion criteria. Most programs preferentially obtain vascular access via the percutaneous route (70%) and many (40%) use mechanical CPR during cannulation. The most commonly used console is the Maquet Rotaflow(Âź). Cannulation is most often performed by cardiothoracic (CT) surgery, and nearly all programs (\u3e85%) involve CT surgeons, perfusionists, and pharmacists. CONCLUSIONS: Over a third of centers that submitted adult eCPR cases to ELSO have performed ED ECMO. These programs are largely based at academic hospitals, new, and have low volumes. They do not have many formal inclusion or exclusion criteria, and devices and techniques are variable

    Method and apparatus for magnetoresistive monitoring of analytes in flow streams

    Get PDF
    Method and apparatus for manipulating and monitoring analyte flowing in fluid streams. A giant magnetoresistive sensor has an array of sensing elements that produce electrical output signals which vary in dependence on changes in the magnetic field proximate the sensing elements. The analyte is included in a stream, such that the stream has a magnetic property which is dependent on the concentration and distribution on the analyte therein. The stream is flowed past the giant magnetoresistive sensor and in sufficiently close proximity to cause the magnetic properties of the stream to produce electrical output signals. The electrical output signals are monitored as an indicator of analyte concentration or distribution in the stream flowing past the GMR sensor. Changes in the magnetic field produced by the background stream are introduced by analyte molecules, whose presence in the flow past the GMR will effect the output reading

    Under-reporting bicycle accidents to police in the COST TU1101 international survey: Cross-country comparisons and associated factors

    Get PDF
    Police crash reports are often the main source for official data in many countries. However, with the exception of fatal crashes, crashes are often underreported in a biased manner. Consequently, the countermeasures adopted according to them may be inefficient. In the case of bicycle crashes, this bias is most acute and it probably varies across countries, with some of them being more prone to reporting accidents to police than others. Assessing if this bias occurs and the size of it can be of great importance for evaluating the risks associated with bicycling. This study utilized data collected in the COST TU1101 action “Towards safer bicycling through optimization of bicycle helmets and usage”. The data came from an online survey that included questions related to bicyclists' attitudes, behaviour, cycling habits, accidents, and patterns of use of helmets. The survey was filled by 8655 bicyclists from 30 different countries. After applying various exclusion factors, 7015 questionnaires filled by adult cyclists from 17 countries, each with at least 100 valid responses, remained in our sample. The results showed that across all countries, an average of only 10% of all crashes were reported to the police, with a wide range among countries: from a minimum of 0.0% (Israel) and 2.6% (Croatia) to a maximum of a 35.0% (Germany). Some factors associated with the reporting levels were type of crash, type of vehicle involved, and injury severity. No relation was found between the likelihood of reporting and the cyclist's gender, age, educational level, marital status, being a parent, use of helmet, and type of bicycle. The significant under-reporting – including injury crashes that do not lead to hospitalization – justifies the use of self-report survey data for assessment of bicycling crash patterns as they relate to (1) crash risk issues such as location, infrastructure, cyclists' characteristics, and use of helmet and (2) strategic approaches to bicycle crash prevention and injury reduction.Fil: Shinar, D.. Ben Gurion University of the Negev; IsraelFil: Valero Mora, Pedro. Universidad de Valencia; EspañaFil: van Strijp Houtenbos, M.. Institute For Road Safety Research; PaĂ­ses BajosFil: Haworth, N.. Queensland University of Technology; AustraliaFil: Schramm, A.. Queensland University of Technology; AustraliaFil: de Bruyne, G.. Universiteit Antwerp; BĂ©lgicaFil: Cavallo, V.. No especifĂ­ca;Fil: Chliaoutakis, J.. No especifĂ­ca;Fil: Pereira Dias, Joao. Instituto Superior Tecnico; PortugalFil: Ferraro, Ottavia Eleonora. Universita Degli Studi Di Pavia; ItaliaFil: Fyhri, Aslak. No especifĂ­ca;Fil: Sajatovic, Anika Hursa. No especifĂ­ca;Fil: Kuklane, Kalev. Lund University; SueciaFil: Ledesma, Ruben Daniel. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro CientĂ­fico TecnolĂłgico Conicet - Mar del Plata. Instituto de PsicologĂ­a BĂĄsica, Aplicada y TecnologĂ­a. Universidad Nacional de Mar del Plata. Facultad de PsicologĂ­a. Instituto de PsicologĂ­a BĂĄsica, Aplicada y TecnologĂ­a.; ArgentinaFil: CalvĂ© Mascarell, Oscar. Ben Gurion University of the Negev; IsraelFil: Morandi, A.. Universita Degli Studi Di Pavia; ItaliaFil: Muser, Markus. No especifĂ­ca;Fil: Otte, Diettmar. No especifĂ­ca;Fil: Papadakaki, M.. No especifĂ­ca;Fil: SanmartĂ­n, J.. Universidad de Valencia; EspañaFil: Dulf, D.. No especifĂ­ca;Fil: Saplioglu, M.. No especifĂ­ca;Fil: Tzamalouka, Georgia. No especifĂ­ca
    • 

    corecore