245 research outputs found

    Focusing a deterministic single-ion beam

    Full text link
    We focus down an ion beam consisting of single 40Ca+ ions to a spot size of a few mum using an einzel-lens. Starting from a segmented linear Paul trap, we have implemented a procedure which allows us to deterministically load a predetermined number of ions by using the potential shaping capabilities of our segmented ion trap. For single-ion loading, an efficiency of 96.7(7)% has been achieved. These ions are then deterministically extracted out of the trap and focused down to a 1sigma-spot radius of (4.6 \pm 1.3)mum at a distance of 257mm from the trap center. Compared to former measurements without ion optics, the einzel-lens is focusing down the single-ion beam by a factor of 12. Due to the small beam divergence and narrow velocity distribution of our ion source, chromatic and spherical aberration at the einzel-lens is vastly reduced, presenting a promising starting point for focusing single ions on their way to a substrate.Comment: 16 pages, 7 figure

    Single ion implantation for single donor devices using Geiger mode detectors

    Full text link
    Electronic devices that are designed to use the properties of single atoms such as donors or defects have become a reality with recent demonstrations of donor spectroscopy, single photon emission sources, and magnetic imaging using defect centers in diamond. Improving single ion detector sensitivity is linked to improving control over the straggle of the ion as well as providing more flexibility in lay-out integration with the active region of the single donor device construction zone by allowing ion sensing at potentially greater distances. Using a remotely located passively gated single ion Geiger mode avalanche diode (SIGMA) detector we have demonstrated 100% detection efficiency at a distance of >75 um from the center of the collecting junction. This detection efficiency is achieved with sensitivity to ~600 or fewer electron-hole pairs produced by the implanted ion. Ion detectors with this sensitivity and integrated with a thin dielectric, for example 5 nm gate oxide, using low energy Sb implantation would have an end of range straggle of <2.5 nm. Significant reduction in false count probability is achieved by modifying the ion beam set-up to allow for cryogenic operation of the SIGMA detector. Using a detection window of 230 ns at 1 Hz, the probability of a false count was measured as 1E-1 and 1E-4 for operation temperatures of 300K and 77K, respectively. Low temperature operation and reduced false, dark, counts are critical to achieving high confidence in single ion arrival. For the device performance in this work, the confidence is calculated as a probability of >98% for counting one and only one ion for a false count probability of 1E-4 at an average ion number per gated window of 0.015.Comment: 10 pages, 5 figures, submitted to Nanotechnolog

    GeVn complexes for silicon-based room-temperature single-atom nanoelectronics

    Get PDF
    We propose germanium-vacancy complexes (GeVn) as a viable ingredient to exploit single-atom quantum effects in silicon devices at room temperature. Our predictions, motivated by the high controllability of the location of the defect via accurate single-atom implantation techniques, are based on ab-initio Density Functional Theory calculations within a parameterfree screened-dependent hybrid functional scheme, suitable to provide reliable bandstructure energies and defect-state wavefunctions. The resulting defect-related excited states, at variance with those arising from conventional dopants such as phosphorous, turn out to be deep enough to ensure device operation up to room temperature and exhibit a far more localized wavefunction

    Magneto-Optical Studies of Exciton Effects in Layer-Type Semiconductors

    Get PDF
    Both experimental and theoretical works were performed with particular reference to a layer-type semiconductor, GaSe, for a coherent treatment of the exciton-like and the oscillatory Landau-like spectra appearing in a form of their combination in semiconductors in magnetic fields. The interband magneto-absorption and the Faraday rotation were measured in pulsed magnetic fields up to ~200 kOe at low temperatures. The theoretical analysis was based mainly on the exact solution for an extremely anisotropic semiconductor in the magnetic field of arbitrary intensity. The exciton effects are discussed in terms of the energy spectrum, the spectral intensity, and the spectral width by the use of the band parameters deduced from the experimental results

    Global associations between regional gray matter volume and diverse complex cognitive functions: evidence from a large sample study

    Get PDF
    Correlations between regional gray matter volume (rGMV) and psychometric test scores have been measured to investigate the neural bases for individual differences in complex cognitive abilities (CCAs). However, such studies have yielded different rGMV correlates of the same CCA. Based on the available evidence, we hypothesized that diverse CCAs are all positively but only weakly associated with rGMV in widespread brain areas. To test this hypothesis, we used the data from a large sample of healthy young adults [776 males and 560 females; mean age: 20.8 years, standard deviation (SD) = 0.8] and investigated associations between rGMV and scores on multiple CCA tasks (including non-verbal reasoning, verbal working memory, Stroop interference, and complex processing speed tasks involving spatial cognition and reasoning). Better performance scores on all tasks except non-verbal reasoning were associated with greater rGMV across widespread brain areas. The effect sizes of individual associations were generally low, consistent with our previous studies. The lack of strong correlations between rGMV and specific CCAs, combined with stringent corrections for multiple comparisons, may lead to different and diverse findings in the field

    Refractive error is associated with intracranial volume

    Get PDF
    Myopia is part of the spectrum of refractive error. Myopia is associated with psychometric intelligence and, the link between brain anatomy and myopia has been hypothesized. Here we aimed to identify the associations between brain structures and refractive error in developed young adults. In a study cohort of 1,319 normal educated young adults, the refractive error showed a signifcant negative correlation with total intracranial volume and total cerebrospinal fuid (CSF) volume but not with total gray matter volume (GMV) or total white matter volume (WMV). Time spent studying was associated with refractive error but could not explain the aforementioned associations with brain volume parameters. The R2 values of the simple regression between spherical equivalent and outcome variables for each sex in non-whole brain imaging analyses were less than 0.05 in all cases and thus were weak. Psychometric intelligence was not associated with refractive error or total CSF volume, but it weakly positively correlated with total GMV and total WMV in this study population. Thus, refractive error appears to be primarily (weakly) associated with the volume of the cranium, whereas psychometric intelligence was associated with the volume of the brain
    corecore