7 research outputs found
Screening of High Temperature Organic Materials for Future Stirling Convertors
Along with major advancement of Stirling-based convertors, high temperature organics are needed to develop future higher temperature convertors for much improved efficiencies as well as to improve the margin of reliability for the current SOA (State-of-the-Art) convertors. The higher temperature capabilities would improve robustness of the convertors and also allow them to be used in additional missions, particularly ones that require a Venus flyby for a gravity assist. Various organic materials have been employed as essential components in the convertor for their unique properties and functions such as bonding, potting, sealing, thread locking, insulation, and lubrication. The Stirling convertor radioisotope generators have been developed for potential future space applications including Lunar/Mars surface power or a variety of spacecraft and vehicles, especially with a long mission cycle, sometimes up to 17 years, such as deep space exploration. Thus, performance, durability, and reliability of the organics should be critically evaluated in terms of every possible material structure-process-service environment relations based on the potential mission specifications. The initial efforts in screening the high temperature candidates focused on the most susceptible organics, such as adhesive, potting compound, O-ring, shrink tubing, and thread locker materials in conjunction with commercially available materials. More systematic and practical test methodologies that were developed and optimized based on the extensive organic evaluations and validations performed for various Stirling convertor types were employed to determine thermal stability, outgassing, and material compatibility of the selected organic candidates against their functional requirements. Processing and fabrication conditions and procedures were also optimized. This report presents results of the three-step candidate evaluation processes, their application limitations, and the final selection recommendations
Lightweight, Durable, and Multifunctional Electrical Insulation Material Systems for High Voltage Applications
Newly developed multilayer structures of well-known polymer insulation materials significantly improved dielectric breakdown voltage, VB, or dielectric strength, K, if well-bonded, when compared to those of single material insulations or the commercial SOA systems, such as Teflon-Kapton-Teflon (TKT), at the same overall thickness. To date, the greatest improvement of the new structures from a few candidate materials, including various types of Kapton PIs and PFA or PET as bond layer (BL), was about 61% higher than that of the Kapton PI alone films, 40.1 vs. 24.9 kV, which was translated to 86.3% decrease in insulation thickness, thus significant volume and weight reduction of the final system. However, it was of interest to note that most improvements of the multilayer structures occurred at thicker overall thicknesses, above ~ 0.15 mm. Extensive analyses also showed that K of the multilayer structures increased with (i) decreasing individual layer thickness regardless of material type, (ii) increasing total accumulated thickness of PI or overall PI/BL ratio, and (iii) increasing number of interface or total number of layers, but only above the aforementioned overall thickness limit. Increases in VB of the multilayer structures were directly correlated with damage evolution and failure mode. With further material-design-process optimizations of the multilayer structures, it was expected to achieve other multifunctionalities, such as high partial discharge (PD) resistance, improved durability, EMI shielding, and high thermal dissipation in addition to high dielectric strength. These new structures can be used in various high voltage and high temperature applications, such as future hybrid or all electric aircraft wiring and power transmission as well as many other non-aerospace high power cables, electronic parts and components, printed circuit board, and so forth. The multilayer insulation system can be easily processed and manufactured with various conductor types via calendaring, compression-molding, stamping, laminating, vacuum-bagging and autoclaving, or 3D printing, even for complex 3-D components. Based on their unique structural configurations and potential capabilities, the new insulation system was identified as micro-multilayer multifunctional electrical insulation (MMEI). Patent application of the MMEI concept and current design configurations was filed for a 1-year provisional application (OAI-58834, Serial No.: 62/659,234), pending conversion to a U.S. utility application. This paper presents details of the MMEI structures, their dielectric performance analyses, potential mechanisms, and commercial scaleup feasibility assessment
Additive Manufacturing of Ultem Polymers and Composites
The objective of this project was to conduct additive manufacturing to produce aircraft engine components by Fused Deposition Modeling (FDM), using commercially available polyetherimdes Ultem 9085 and experimental Ultem 1000 filled with 10 chopped carbon fiber. A property comparison between FDM-printed and injection molded coupons for Ultem 9085, Ultem 1000 resin and the fiber-filled composite Ultem 1000 was carried out. Furthermore, an acoustic liner was printed from Ultem 9085 simulating conventional honeycomb structured liners and tested in a wind tunnel. Composite compressor inlet guide vanes were also printed using fiber-filled Ultem 1000 filaments and tested in a cascade rig. The fiber-filled Ultem 1000 filaments and composite vanes were characterized by scanning electron microscope (SEM) and acid digestion to determine the porosity of FDM-printed articles which ranged from 25-31. Coupons of Ultem 9085, experimental Ultem 1000 composites and XH6050 resin were tested at room temperature and 400F to evaluate their corresponding mechanical properties
Thermal Analysis of Potted Litz Wire for High-Power-Density Aerospace Electric Machines
Increasing the power density and efficiency of electric machines (motors and generators) is integral to bringing Electrified Aircraft (EA) to commercial realization. To that end an effort to create a High Efficiency Megawatt Motor (HEMM) with a goal of exceeding 98% efficiency and 1.46 MW of power has been undertaken at the NASA Glenn Research Center. Of the motor components the resistive losses in the stator windings are by far the largest contributor (34%) to total motor loss. The challenge is the linear relationship between resistivity and temperature, making machine operation sensitive to temperature increases. In order to accurately predict the thermal behavior of the stator the thermal conductivity of the Litz wire-potting-electrical insulation system must be known. Unfortunately, this multi material system has a wide range of thermal conductivities (0.1 W/m-K 400 W/m-K) and a high anisotropy (axial vs transverse) making the prediction of the transverse thermal conductivity an in turn the hot spot temperatures in the windings is difficult. In order to do this a device that simulates the thermal environment found in the HEMM stator was designed. This device is not unlike the motorettes (little motors) that are described in IEEE standards for testing electrical insulation lifetimes or other electric motor testing. However, because the HEMM motor design includes significant rotor electrical and thermal considerations the term motorette was not deemed appropriate. Instead statorette (or little stator) was adopted as the term for this test device. This paper discussed the design, thermal heat conjugate analysis (thermal model), manufacturing and testing of HEMM's statorette. Analysis of the results is done by thermal resistance network model and micro thermal model and is compared to analytical predictions of thermal conductivity of the insulated and potted Litz wire system
Aerospace Environmental Challenges for Electrical Insulation and Recent Developments for Electrified Aircraft
The growing trend towards high voltage electrical assets and propulsion in the aeronautics and space industry pose new challenges in electrical insulation materials that cannot be overlooked. Transition to new high voltage electrified systems with unprecedented high levels of voltage, power, and efficiency must be safe and reliable. Improvements in both performance and safety of megawatt power systems is complicated because of the need for additional power transmission wiring and cabling and new safety requirements that have the potential of making the resulting systems heavier. To mitigate this issue, novel lightweight materials and system solutions are required that would result in lower specific weights in the insulator and conductor. Although reduced size and weight of system components can be achieved with new concepts, designs, and technologies, the high voltage (≥300 V) operation presents a significant challenge. This challenge is further complicated when considering the extreme operating environment that is experienced in aircraft, spacecraft, and targeted human exploration destinations. This paper reviews the extreme environmental challenges for aerospace electrical insulation and the needs associated with operating under high voltage and extreme environments. It also examines several recently developed robust lightweight electrical insulation materials that could enhance insulation performance and life. In aerospace, research must consider mass when developing new technologies. The impact of these recent developments provides a pathway which could enable next generation high altitude all electric aircraft, lightweight power transmission cables for a future sustained presence on the Moon and missions to Mars using HV propulsion, such as spacecraft with Nuclear Electric Propulsion systems
Outcomes in Newly Diagnosed Atrial Fibrillation and History of Acute Coronary Syndromes: Insights from GARFIELD-AF
BACKGROUND: Many patients with atrial fibrillation have concomitant coronary artery disease with or without acute coronary syndromes and are in need of additional antithrombotic therapy. There are few data on the long-term clinical outcome of atrial fibrillation patients with a history of acute coronary syndrome. This is a 2-year study of atrial fibrillation patients with or without a history of acute coronary syndromes