55 research outputs found

    Poly[bis­(ÎŒ2-4,4â€Č-bipyridine)­bis­(3-nitro­benzoato)nickel(II)]

    Get PDF
    The crystal structure of the title complex, [Ni(C7H4NO4)2(C10H8N2)2]n, exhibits a two-dimensional network, which is built up from slightly distorted NiN4O2 polyhedra (2 symmetry), bipyridine ligands, and carboxyl­ate anions. The NiII atoms are six-coordinated by two O atoms of two monodentate carboxyl­ate anions and four N atoms from bipyridine ligands and are connected into layers by the 4,4â€Č-bipyridine ligands

    Well-differentiated gall bladder hepatoid carcinoma producing alpha-fetoprotein: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Gall bladder carcinoma is rare, and metastatic gall bladder carcinoma from hepatocellular carcinoma has been reported in only a few patients.</p> <p>Case presentation</p> <p>We present a 73-year-old man with a history of hepatitis B virus-related liver cirrhosis and hepatocellular carcinoma. He received transcatheter arterial chemoembolization, and was diagnosed to have an alpha-fetoprotein producing gall bladder tumor with intraluminal growth. Open cholecystectomy was performed. Pathologic examination of the lesion revealed a well-differentiated hepatoid carcinoma. The lesion was thought most likely to be a metastatic lesion from previous hepatocellular carcinoma. His alpha-fetoprotein level dropped to normal levels five months after the surgery.</p> <p>Conclusion</p> <p>This unusual intraluminal growing tumor proved to be a well-differentiated hepatoid carcinoma, most likely a metastatic lesion from previous hepatocellular carcinoma. This case reminds clinicians that in looking for likely hepatocellular carcinoma recurrence, when no detectable hepatic lesion can account for an elevated alpha-fetoprotein level, the gall bladder should be included in the search for the site of metastasis.</p

    Benzodiazepines Associated With Acute Respiratory Failure in Patients With Obstructive Sleep Apnea

    Get PDF
    Aims: Obstructive sleep apnea (OSA) and insomnia commonly coexist; hypnotics are broadly prescribed for insomnia therapy. However, the safety of hypnotics use in OSA patients is unclear. We conducted a retrospective case-control study to investigate the risk of adverse respiratory events in hypnotics-using OSA patients.Methods: We obtained data from the Taiwan National Health Insurance Database from 1996 to 2013. The case group included 216 OSA patients with newly diagnosed adverse respiratory events, including pneumonia and acute respiratory failure. The control group included OSA patients without adverse respiratory events, which was randomly frequency-matched to the case group at a 1:1 ratio according to age, gender, and index year. Hypnotics exposure included benzodiazepines (BZD) and non-benzodiazepines (non-BZD). A recent user was defined as a patient who had taken hypnotics for 1–30 days, while a long-term user was one who had taken hypnotics for 31–365 days.Results: Multivariable adjusted analysis showed recent BZD use is an independent risk for adverse respiratory events (OR = 2.70; 95% CI = 1.15–6.33; P &lt; 0.001). Subgroup analysis showed both recent and long-term BZD use increased the risk of acute respiratory failure compared to never BZD use (OR = 28.6; 95% CI = 5.24–156; P &lt; 0.001, OR = 10.1; 95% CI = 1.51–67.7; P &lt; 0.05, respectively). Neither BZD nor non-BZD use increased the risk of pneumonia in OSA patients.Conclusion: BZD use might increase the risk of acute respiratory failure in OSA patients

    Real-Time Gait Cycle Parameter Recognition Using a Wearable Accelerometry System

    Get PDF
    This paper presents the development of a wearable accelerometry system for real-time gait cycle parameter recognition. Using a tri-axial accelerometer, the wearable motion detector is a single waist-mounted device to measure trunk accelerations during walking. Several gait cycle parameters, including cadence, step regularity, stride regularity and step symmetry can be estimated in real-time by using autocorrelation procedure. For validation purposes, five Parkinson’s disease (PD) patients and five young healthy adults were recruited in an experiment. The gait cycle parameters among the two subject groups of different mobility can be quantified and distinguished by the system. Practical considerations and limitations for implementing the autocorrelation procedure in such a real-time system are also discussed. This study can be extended to the future attempts in real-time detection of disabling gaits, such as festinating or freezing of gait in PD patients. Ambulatory rehabilitation, gait assessment and personal telecare for people with gait disorders are also possible applications

    International Consensus Statement on Rhinology and Allergy: Rhinosinusitis

    Get PDF
    Background: The 5 years since the publication of the first International Consensus Statement on Allergy and Rhinology: Rhinosinusitis (ICAR‐RS) has witnessed foundational progress in our understanding and treatment of rhinologic disease. These advances are reflected within the more than 40 new topics covered within the ICAR‐RS‐2021 as well as updates to the original 140 topics. This executive summary consolidates the evidence‐based findings of the document. Methods: ICAR‐RS presents over 180 topics in the forms of evidence‐based reviews with recommendations (EBRRs), evidence‐based reviews, and literature reviews. The highest grade structured recommendations of the EBRR sections are summarized in this executive summary. Results: ICAR‐RS‐2021 covers 22 topics regarding the medical management of RS, which are grade A/B and are presented in the executive summary. Additionally, 4 topics regarding the surgical management of RS are grade A/B and are presented in the executive summary. Finally, a comprehensive evidence‐based management algorithm is provided. Conclusion: This ICAR‐RS‐2021 executive summary provides a compilation of the evidence‐based recommendations for medical and surgical treatment of the most common forms of RS

    Piezoelectric Response Evaluation of ZnO Thin Film Prepared by RF Magnetron Sputtering

    No full text
    The most important parameter of piezoelectric materials is piezoelectric coefficient (d33). In this study, the piezoelectric ZnO thin films were deposited on the SiNx/Si substrate. The 4 inches substrate is diced into 8 cm× 8 cm piece. During the deposition process, a zinc target (99.999 wt%) of 2 inches diameter was used. The vertical distance between the target and the substrate holder was fixed at 5 cm. The piezoelectric response of zinc oxide (ZnO) thin films were obtained by using a direct measurement system. The system adopts a mini impact tip to generate an impulsive force and read out the piezoelectric signals immediately. Experimentally, a servo motor is used to produce a fixed quantity of force, for giving an impact against to the piezoelectric film. The ZnO thin films were deposited using the reactive radio frequency (RF) magnetron sputtering method. The electric charges should be generated because of the material’s extrusion. This phenomenon was investigated through the oscilloscope by one shot trigger. It was apparent that all ZnO films exhibit piezoelectric responses evaluated by our measurement system, however, its exhibit a significant discrepancy. The piezoelectric responses of ZnO thin film at various deposition positions were measured and the crystal structures of the sputtering pressure were also discussed. The crystalline characteristics of ZnO thin films are investigated through the XRD and SEM. The results show the ZnO thin film exhibits good crystalline pattern and surface morphology with controlled sputtering condition. The ZnO thin films sputtered using 2 inches target present various piezoelectric responses. With the exactly related position, a best piezoelectric response of ZnO thin film can be achieved
    • 

    corecore