2,400 research outputs found

    Optimization the initial weights of artificial neural networks via genetic algorithm applied to hip bone fracture prediction

    Get PDF
    This paper aims to find the optimal set of initial weights to enhance the accuracy of artificial neural networks (ANNs) by using genetic algorithms (GA). The sample in this study included 228 patients with first low-trauma hip fracture and 215 patients without hip fracture, both of them were interviewed with 78 questions. We used logistic regression to select 5 important factors (i.e., bone mineral density, experience of fracture, average hand grip strength, intake of coffee, and peak expiratory flow rate) for building artificial neural networks to predict the probabilities of hip fractures. Three-layer (one hidden layer) ANNs models with back-propagation training algorithms were adopted. The purpose in this paper is to find the optimal initial weights of neural networks via genetic algorithm to improve the predictability. Area under the ROC curve (AUC) was used to assess the performance of neural networks. The study results showed the genetic algorithm obtained an AUC of 0.858±0.00493 on modeling data and 0.802 ± 0.03318 on testing data. They were slightly better than the results of our previous study (0.868±0.00387 and 0.796±0.02559, resp.). Thus, the preliminary study for only using simple GA has been proved to be effective for improving the accuracy of artificial neural networks.This research was supported by the National Science Council (NSC) of Taiwan (Grant no. NSC98-2915-I-155-005), the Department of Education grant of Excellent Teaching Program of Yuan Ze University (Grant no. 217517) and the Center for Dynamical Biomarkers and Translational Medicine supported by National Science Council (Grant no. NSC 100- 2911-I-008-001)

    Measuring and analysing vibration motors in insoles via accelerometers

    Get PDF
    Purpose: Falling is a major public health concern among elderly people, and they often cause serious injuries1,2. They most frequently occur during walking and are associated with the chronic deterioration in the neuromuscular and sensory systems, as well as with ankle muscle weakness and lower endurance of these muscles to fatigue1,3. Vibrating insoles, providing a subsensory mechanical noise signal to the plantar side of the feet, may improve balance in healthy young and older people and in patients with stroke or diabetic neuropathy4. The object of this study is to find the most suitable vibrator to put into the insole which can effectively improve the balance control of the elderlies. Method: We choose three different vibration actuators (micro vibration motor, brushless motor and eccentric motor) with two different weights on the insole. First, we put three same motors and two accelerometers on the insole, as shown in Figure1, then attach another layer on both side of the insole. Second, connect the motors to the power supply and the accelerometer to NI PXI-1033 spectrum analyzer which is used to collect the accelerometers' data. At last, using Fast Fourier Transform (FFT) to analyze and compare the results to see which motor is the most stable and suitable to put into the insole. Results & Discussion: The results showed that the most stable one is the brushless motor. The reason why the frequency is stable is that the relationship between voltage and frequency is linear, and the error is small through continuous measurements. On the other hand, when a person weight 55 kg stands on the insole, the frequency isn't affected by the weight. These two results appear very similar to each other, as shown in Figure 2. According to the result, we use the brushless motor to be our vibrator in the insole, and hope this will help the elderlies improve their balance control ability more efficiency

    Investigating properties of the cardiovascular system using innovative analysis algorithms based on ensemble empirical mode decomposition

    Get PDF
    This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited - Copyright @ 2012 Jia-Rong Yeh et al.Cardiovascular system is known to be nonlinear and nonstationary. Traditional linear assessments algorithms of arterial stiffness and systemic resistance of cardiac system accompany the problem of nonstationary or inconvenience in practical applications. In this pilot study, two new assessment methods were developed: the first is ensemble empirical mode decomposition based reflection index (EEMD-RI) while the second is based on the phase shift between ECG and BP on cardiac oscillation. Both methods utilise the EEMD algorithm which is suitable for nonlinear and nonstationary systems. These methods were used to investigate the properties of arterial stiffness and systemic resistance for a pig's cardiovascular system via ECG and blood pressure (BP). This experiment simulated a sequence of continuous changes of blood pressure arising from steady condition to high blood pressure by clamping the artery and an inverse by relaxing the artery. As a hypothesis, the arterial stiffness and systemic resistance should vary with the blood pressure due to clamping and relaxing the artery. The results show statistically significant correlations between BP, EEMD-based RI, and the phase shift between ECG and BP on cardiac oscillation. The two assessments results demonstrate the merits of the EEMD for signal analysis.This work is supported by the National Science Council (NSC) of Taiwan (Grant number NSC 99-2221-E-155-046-MY3), Centre for Dynamical Biomarkers and Translational Medicine, National Central University, Taiwan which is sponsored by National Science Council (Grant number: NSC 100–2911-I-008-001) and the Chung-Shan Institute of Science & Technology in Taiwan (Grant numbers: CSIST-095-V101 and CSIST-095-V102)

    Permanent Deformation of Earth Dams Under Earthquakes

    Get PDF
    Assessment of dam embankment deformation by various methods such as those proposed by Newmark, Ambraseys and Seed was reviewed herewith. A simple method based on dynamic response spectrum analyses by step-by-step integration technique is proposed for independent permanent deformation evaluation. The proposed method assumes that failure occurs on a well-defined slip surface and that the material behaves elastically at stress level below failure but develops a perfectly plastic behavior above the yield acceleration. The results of the proposed method were compared with those obtained from other method for actual examples. Favorable agreement on the analytical results was achieved

    Erosion and release from biodegradable polyanhydrides

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Whitaker College of Health Sciences and Technology, 1995.Includes bibliographical references (leaves 105-109).by Lisa Y. Shieh.Ph.D

    Large strain actuation in barium titanate single crystals under stress and electric field

    Get PDF
    Large strain actuation in barium titanate (BaTiO3) single crystals subjected to combined uniaxial stress and electric field is examined. A maximum strain of about 0.45% is measured under a combined loading of 2.7 MPa compressive stress and ±1.25 MVm-1 cyclic electric field. Above 2.7 MPa, the crystal does not cycle fully between the in-plane and out-of-plane polarized states due to large compressive stress, and consequently, a considerable reduction in actuation strain is apparent. The hysteresis evolution of the crystal under combined electromechanical loading reveals incomplete switching characteristics and a considerable disproportion of slope gradients at zero electric field for the measured polarization and strain hysteresis curves. A likely cause for the disproportion of slope gradients is the cooperative operation of multiple 90° switching systems by which “polarization-free” strain changes are induced

    Single Cell Gap Transflective Liquid Crystal Display with Slanted Reflector Above Transmissive Pixels

    Get PDF
    Single cell gap transflective liquid crystal display which provides that the backlight traverses the reflective pixel portion twice and thereby follows a path similar to that of the ambient light. A slant reflector is built on the path of the back light to reflect the transmitted light to the reflective portion so that the back light and ambient light follow similar paths

    Type-2 fuzzy sets applied to multivariable self-organizing fuzzy logic controllers for regulating anesthesia

    Get PDF
    In this paper, novel interval and general type-2 self-organizing fuzzy logic controllers (SOFLCs) are proposed for the automatic control of anesthesia during surgical procedures. The type-2 SOFLC is a hierarchical adaptive fuzzy controller able to generate and modify its rule-base in response to the controller's performance. The type-2 SOFLC uses type-2 fuzzy sets derived from real surgical data capturing patient variability in monitored physiological parameters during anesthetic sedation, which are used to define the footprint of uncertainty (FOU) of the type-2 fuzzy sets. Experimental simulations were carried out to evaluate the performance of the type-2 SOFLCs in their ability to control anesthetic delivery rates for maintaining desired physiological set points for anesthesia (muscle relaxation and blood pressure) under signal and patient noise. Results show that the type-2 SOFLCs can perform well and outperform previous type-1 SOFLC and comparative approaches for anesthesia control producing lower performance errors while using better defined rules in regulating anesthesia set points while handling the control uncertainties. The results are further supported by statistical analysis which also show that zSlices general type-2 SOFLCs are able to outperform interval type-2 SOFLC in terms of their steady state performance
    corecore