1,654 research outputs found
Alliances and American National Security
One of the greatest challenges facing the United States today is the translation of its overwhelming might into effective influence. Traditionally, the United States has leveraged its power through bilateral and multilateral alliances. However, the end of the Cold War and the events of September 11, 2001, have led some policymakers and analysts to question the value of alliances in American foreign and defense policy. This monograph advocates that allies are more important than ever to the achievement of U.S. national security goals.https://press.armywarcollege.edu/monographs/1366/thumbnail.jp
Measurement of outflow facility using iPerfusion
Elevated intraocular pressure (IOP) is the predominant risk factor for glaucoma, and reducing IOP is the only successful strategy to prevent further glaucomatous vision loss. IOP is determined by the balance between the rates of aqueous humour secretion and outflow, and a pathological reduction in the hydraulic conductance of outflow, known as outflow facility, is responsible for IOP elevation in glaucoma. Mouse models are often used to investigate the mechanisms controlling outflow facility, but the diminutive size of the mouse eye makes measurement of outflow technically challenging. In this study, we present a new approach to measure and analyse outflow facility using iPerfusionâ„¢, which incorporates an actuated pressure reservoir, thermal flow sensor, differential pressure measurement and an automated computerised interface. In enucleated eyes from C57BL/6J mice, the flow-pressure relationship is highly non-linear and is well represented by an empirical power law model that describes the pressure dependence of outflow facility. At zero pressure, the measured flow is indistinguishable from zero, confirming the absence of any significant pressure independent flow in enucleated eyes. Comparison with the commonly used 2-parameter linear outflow model reveals that inappropriate application of a linear fit to a non-linear flow-pressure relationship introduces considerable errors in the estimation of outflow facility and leads to the false impression of pressure-independent outflow. Data from a population of enucleated eyes from C57BL/6J mice show that outflow facility is best described by a lognormal distribution, with 6-fold variability between individuals, but with relatively tight correlation of facility between fellow eyes. iPerfusion represents a platform technology to accurately and robustly characterise the flow-pressure relationship in enucleated mouse eyes for the purpose of glaucoma research and with minor modifications, may be applied in vivo to mice, as well as to eyes from other species or different biofluidic systems
Recommended from our members
Monoaromatic compounds in ambient air of various cities: A focus on correlations between the xylenes and ethylbenzene
Speciation of o-xylene, m-xylene, p-xylene and ethylbenzene was performed by gas chromatography from ambient air and liquid fuel samples collected at various locations in 19 cities in Europe, Asia and South America. The xylene's mixing ratios were compared to each other from the various locations, which included urban air, traffic air and liquid fuel. For all samples, the xylenes exhibited robust correlations, and the slopes remained constant. The m-xylene/p-xylene ratio was found to be 2.33±0.30, and the m-xylene/o-xylene ratio was found to be 1.84±0.25. These ratios remain persistent even in biomass combustion experiments (in South America and South Africa). Comparing the xylenes to toluene and benzene indicate that combustion, but not fuel evaporation, is the major common source of the xylenes in areas dominated by automotive emissions. Although a wide range of combustion types and combustion efficiencies were encountered throughout all the locations investigated, xylenes and ethylbenzene ratios remained persistent. We discuss the implications of the constancies in the xylenes and ethylbenzene ratios on atmospheric chemistry
Recommended from our members
Influence of the public transportation system on the air quality of a major urban center. A case study: Milan, Italy
A sampling campaign was conducted in the city of Milan, Italy before and during a transportation strike in January 2004. This strike provided a unique opportunity to investigate the influence of public transportation on the air quality in a major metropolitan area. Twenty-four air samples were collected each day around the city on January 2nd, 7th and 9th. The samples were analyzed for methane, carbon monoxide, non-methane hydrocarbons (NMHCs), halocarbons and alkyl nitrates. Significant differences in the mixing ratios were observed among the three days of sampling, with January 2nd showing the lowest concentrations as a result of decreased activity in the city during the holiday season. January 9th showed the highest NMHC concentrations because of increased vehicular activity in the city due to a public transportation strike. This paper investigates the correlation between the increased number of vehicles and decreased air quality because of a reduction in public transportation. Computer simulations were able to reproduce measurements of ozone production during the January 2004 strike and a July 2005 strike. The measurements and simulations suggest that reduced VOC emissions due to the existence of public transportation lowers peak ozone by 11-33% during the summer months. © 2008 Elsevier Ltd. All rights reserved
Recommended from our members
Measurements of nonmethane hydrocarbons in 28 United States cities
Between 1999 and 2005 a sampling campaign was conducted to identify and quantify the major species of atmospheric nonmethane hydrocarbons (NMHCs) in United States cities. Whole air canister samples were collected in 28 cities and analyzed for methane, carbon monoxide (CO) and NMHCs. Ambient mixing ratios exhibited high inter- and intra-city variability, often having standard deviations in excess of 50% of the mean value. For this reason, ratios of individual NMHC to CO, a combustion tracer, were examined to facilitate comparison between cities. Ratios were taken from correlation plots between the species of interest and CO, and most NMHCs were found to have correlation coefficients (r2) greater than 0.6, particularly ethene, ethyne and benzene, highlighting the influence of vehicular emissions on NMHC mixing ratios. Notable exceptions were the short-chain alkanes, which generally had poor correlations with CO. Ratios of NMHC vs. CO were also used to identify those cities with unique NMHC sources. © 2007 Elsevier Ltd. All rights reserved
Recommended from our members
Ambient halocarbon mixing ratios in 45 Chinese cities
During this study 158 whole air samples were collected in 45 Chinese cities in January and February 2001. The spatial distribution of different classes of halocarbons in the Chinese urban atmosphere, including chlorofluorocarbons (CFCs), hydrochlorofluorocarbons (HCFCs), hydrofluorocarbons (HFCs), Halon-1211, and other chlorinated compounds is presented and discussed. Most of these compounds were enhanced compared to background levels. However, the mean enhancement of CFCs was relatively small, with CFC-12 and CFC-11 increases of 6% (range 1-31%) and 10% (range 2-89%), respectively, with respect to the global background. On the contrary, strongly enhanced levels of CFC replacement compounds and halogenated compounds used as solvents were measured. The average Halon-1211 concentration exceeded the background of 4.3 pptv by 75% and was higher than 10 pptv in several cities. Methyl chloride mixing ratios were also strongly elevated (78% higher than background levels), which is likely related to the widespread use of coal and biofuel in China. © 2006 Elsevier Ltd. All rights reserved
Localized and controlled delivery of nitric oxide to the conventional outflow pathway via enzyme biocatalysis: towards therapy for Glaucoma
Nitric oxide (NO) has been shown to lower intraocular pressure (IOP), however its therapeutic effects on outflow physiology are location- and dose-dependent. Here, a NO delivery platform that directly targets the resistance-generating region of the conventional outflow pathway and locally liberates a controlled dose of NO is reported. An increase in outflow facility (decrease in IOP) is demonstrated in mouse model
Recommended from our members
Hydroxyl concentration estimates in the sunlit snowpack at Summit, Greenland
Experiments were performed at Summit, Greenland (72°34′ N, 38°29′ W) to investigate hydroxyl mixing ratios in the sunlit surface snowpack (or firn). We added a carefully selected mixture of hydrocarbon gases (with a wide range of hydroxyl reactivities) to a UV and visible light transparent flow chamber containing undisturbed natural firn. The relative decrease in mixing ratios of these gases allowed estimation of the lower limit mixing ratio of hydroxyl radicals in the near-surface firn pore spaces. Hydroxyl mixing ratios in the firn air followed a diurnal cycle in summer 2003 (10-12 July), with peak values of more than 3.2×106 molecules cm-3 between 13:00 and 16:00 local time. The minimum value estimated was 1.1×106 molecules cm-3 at 20:00 local time. Results during spring of 2004 showed lower, but rapidly increasing, peak hydroxyl mixing ratios of 1.1×106 molecules cm-3 in the early afternoon on 15 April and 1.5×106 molecules cm-3 on 1 May. Our firn hydroxyl estimates were similar to directly measured above-snow ambient levels during the spring field season, but were only about 30% of ambient levels during summer. © 2007 Elsevier Ltd. All rights reserved
Measurement of postmortem outflow facility using iPerfusion.
The key risk factor for glaucoma is elevation of intraocular pressure (IOP) and alleviating it is the only effective therapeutic approach to inhibit further vision loss. IOP is regulated by the flow of aqueous humour across resistive tissues, and a reduction in outflow facility, is responsible for the IOP elevation in glaucoma. Measurement of outflow facility is therefore important when investigating the pathophysiology of glaucoma and testing candidate treatments for lowering IOP. Due to similar anatomy and response to pharmacological treatments, mouse eyes are a common model of human aqueous humour dynamics. The ex vivo preparation, in which an enucleated mouse eye is mounted in a temperature controlled bath and cannulated, has been well characterised and is widely used. The postmortem in situ model, in which the eyes are perfused within the cadaver, has received relatively little attention. In this study, we investigate the postmortem in situ model using the iPerfusion system, with a particular focus on i) the presence or absence of pressure-independent flow, ii) the effect of evaporation on measured flow rates and iii) the magnitude and pressure dependence of outflow facility and how these properties are affected by postmortem changes. Measurements immediately after cannulation and following multi-pressure facility measurement demonstrated negligible pressure-independent flow in postmortem eyes, in contrast to assumptions made in previous studies. Using a humidity chamber, we investigated whether the humidity of the surrounding air would influence measured flow rates. We found that at room levels of humidity, evaporation of saline droplets on the eye resulted in artefactual flow rates with a magnitude comparable to outflow, which were eliminated by a high relative humidity (>85%) environment. Average postmortem outflow facility was ∼4 nl/min/mmHg, similar to values observed ex vivo, irrespective of whether a postmortem delay was introduced prior to cannulation. The intra-animal variability of measured outflow facility values was also reduced relative to previous ex vivo data. The pressure-dependence of outflow facility was reduced in the postmortem relative to ex vivo model, and practically eliminated when eyes were cannulated >40 min after euthanisation. Overall, our results indicate that the moderately increased technical complexity associated with postmortem perfusion provides reduced variability and reduced pressure-dependence in outflow facility, when experimental conditions are properly controlled
- …