416 research outputs found

    Assessment of correlation between knee notch width index and the three-dimensional notch volume

    Get PDF
    This study was done to determine whether there is a correlation between the notch volume and the notch width index (NWI) as measured on the three most frequently used radiographic views: the Holmblad 45°, Holmblad 70°, and Rosenberg view. The notch volume of 20 cadaveric knees was measured using Computed Tomography (CT). The Holmblad 45°, Holmblad 70°, and Rosenberg notch view radiographs were digitally re-created from the CT scans for each specimen, and the NWI was measured by two observers. The Pearson correlation coefficient between the NWI and notch volume was calculated, as well as between the three views. An independent t test was performed to determine the difference in NWI and notch volume between male and female specimens. The reliability for each view was also determined. There was no correlation between the NWI as measured on the Holmblad 45°, Holmblad 70°, or Rosenberg view and the notch volume. All three radiographic views proved reliable, but showed only a moderate correlation with each other. Men had larger notch volumes than women, but there was no difference in NWI. A knee with a small intercondylar notch is often considered an increased risk for ACL rupture. The NWI is a frequently used two-dimensional method to determine notch size. However, in the present study, this index was not positively correlated with the overall volume of the notch. Based on the results of the current study, the authors would advice to use caution when using notch view radiographs in a clinical setting to predict risk of ACL rupture

    Isometry of medial collateral ligament reconstruction

    Get PDF
    The purpose of this study was to determine the femoral and tibial fixation sites that would result in the most isometric MCL reconstruction technique. Seven cadaveric knees were used in this study. A navigation system was utilized to determine graft isometry continuously from 0º to 90º. Five points on the medial side of the femur and four on the tibia were tested. A graft positioned in the center of the MCL femoral attachment (FC) and attached in the center of the superficial MCL attachment on the tibia led to the best isometry (2.7 ± 1.1 mm). Movement of the origin superiorly only 4 mm (FS) led to graft excursion of greater than 10 mm (P < 0.01). MCL reconstruction performed with the origin of the MCL within the femoral footprint and the insertion in tibial footprint of the superficial MCL results in the least graft excursion when the knee is cycled between 0º and 90º. Although the MCL often heals without surgical intervention, surgical reconstruction is occasionally in Grade III MCL and combined ligamentous injuries to the knee. This study demonstrates the optimal position of the MCL reconstruction to reproduce the kinematics of the native knee

    Outcomes of Operatively Treated Acute Knee Dislocations

    Get PDF
    Knee dislocation is a complex and rare injury often presenting in the context of high velocity trauma. The aim of this study is to establish the subjective outcomes of surgically treated knee dislocations. A total of 20 knees dislocations treated by open repair were reviewed. Their progress and outcomes were assessed by using a modified Lysholm score questionnaire. Data was obtained on patient demographics, details of injury, investigation, treatment, rehabilitation, 24 months objective outcome and subjective outcomes. Six patients had a vascular deficit and six had neurological deficits. The median range of motion was 0°-100°. Patients with an initially lower pre-injury level of function were able to return an activity level comparable to their pre-injury status. 22% of competitive athletes retuned to competitive sports. 38% of patients undertaking heavy activity returned to comparable pre-injury level of activity and 67% of patients undertaking moderate level of activity before injury returned to a comparable level after repair. 68% regularly had problems running, 70% problem squatting, 40% swelling and 42% problem with stairs. Most patients however did not have locking of the knee or problems with knees giving way. Patients pain scores decreased over time to an acceptable level. Despite the severity of the injury, majority of patients achieved a satisfactory outcome, although none of the patients reached the same level of function as before the injury. 80% of the patients were satisfied with their outcome. All dissatisfied patients suffered postoperative complications

    Management of anterior cruciate ligament rupture in patients aged 40 years and older

    Get PDF
    The aim of anterior cruciate ligament (ACL) reconstruction is essentially to restore functional stability of the knee and to allow patients to return to their desired work and activities. While in the young and active population, surgery is often the best therapeutic option after an ACL tear, ACL reconstruction in middle-aged people is rather more controversial due to concerns about a higher complication rate. The purpose of our article is to establish, through a systematic review of the literature, useful decision-making criteria for the management of anterior cruciate ligament rupture in patients aged 40 years and older, guiding surgeons to the most appropriate therapeutic approach. Various reports have shown excellent results of ACL reconstruction in patients over the age of 40 in terms of subjective satisfaction, return to previous activity level, and reduced complication and failure rates. Some even document excellent outcomes in subjects of 50 years and older. Although there are limited high-level studies, data reported in the literature suggest that ACL reconstruction can be successful in appropriately selected, motivated older patients with symptomatic knee instability who want to return to participating in highly demanding sport and recreational activities. Deciding factors are based on occupation, sex, activity level of the subject, amount of time spent performing such highly demanding activities, and presence of associated knee lesions. Physiological age and activity level are more important than chronological age as deciding factors when considering ACL reconstruction

    Biomechanics and anterior cruciate ligament reconstruction

    Get PDF
    For years, bioengineers and orthopaedic surgeons have applied the principles of mechanics to gain valuable information about the complex function of the anterior cruciate ligament (ACL). The results of these investigations have provided scientific data for surgeons to improve methods of ACL reconstruction and postoperative rehabilitation. This review paper will present specific examples of how the field of biomechanics has impacted the evolution of ACL research. The anatomy and biomechanics of the ACL as well as the discovery of new tools in ACL-related biomechanical study are first introduced. Some important factors affecting the surgical outcome of ACL reconstruction, including graft selection, tunnel placement, initial graft tension, graft fixation, graft tunnel motion and healing, are then discussed. The scientific basis for the new surgical procedure, i.e., anatomic double bundle ACL reconstruction, designed to regain rotatory stability of the knee, is presented. To conclude, the future role of biomechanics in gaining valuable in-vivo data that can further advance the understanding of the ACL and ACL graft function in order to improve the patient outcome following ACL reconstruction is suggested

    Intraarticular location predicts cartilage filling and subchondral bone changes in a chondral defect: A randomized, blind, long-term follow-up trial involving 82 rabbit knees

    Get PDF
    Open Access - This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited.Background and purpose: The natural history of, and predictive factors for outcome of cartilage restoration in chondral defects are poorly understood. We investigated the natural history of cartilage filling subchondral bone changes, comparing defects at two locations in the rabbit knee. Animals and methods: In New Zealand rabbits aged 22 weeks, a 4-mm pure chondral defect (ICRS grade 3b) was created in the patella of one knee and in the medial femoral condyle of the other. A stereo microscope was used to optimize the preparation of the defects. The animals were killed 12, 24, and 36 weeks after surgery. Defect filling and the density of subchondral mineralized tissue was estimated using Analysis Pro software on micrographed histological sections. Results: The mean filling of the patellar defects was more than twice that of the medial femoral condylar defects at 24 and 36 weeks of follow-up. There was a statistically significant increase in filling from 24 to 36 weeks after surgery at both locations. The density of subchondral mineralized tissue beneath the defects subsided with time in the patellas, in contrast to the density in the medial femoral condyles, which remained unchanged. Interpretation: The intraarticular location is a predictive factor for spontaneous filling and subchondral bone changes of chondral defects corresponding to ICRS grade 3b. Disregarding location, the spontaneous filling increased with long-term follow-up. This should be considered when evaluating aspects of cartilage restoration

    Revision 1 Size and position of the healthy meniscus, and its Correlation with sex, height, weight, and bone area- a cross-sectional study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Meniscus extrusion or hypertrophy may occur in knee osteoarthritis (OA). However, currently no data are available on the position and size of the meniscus in asymptomatic men and women with normal meniscus integrity.</p> <p>Methods</p> <p>Three-dimensional coronal DESSwe MRIs were used to segment and quantitatively measure the size and position of the medial and lateral menisci, and their correlation with sex, height, weight, and tibial plateau area. 102 knees (40 male and 62 female) were drawn from the Osteoarthritis Initiative "non-exposed" reference cohort, including subjects without symptoms, radiographic signs, or risk factors for knee OA. Knees with MRI signs of meniscus lesions were excluded.</p> <p>Results</p> <p>The tibial plateau area was significantly larger (p < 0.001) in male knees than in female ones (+23% medially; +28% laterally), as was total meniscus surface area (p < 0.001, +20% medially; +26% laterally). Ipsi-compartimental tibial plateau area was more strongly correlated with total meniscus surface area in men (r = .72 medially; r = .62 laterally) and women (r = .67; r = .75) than contra-compartimental or total tibial plateau area, body height or weight. The ratio of meniscus versus tibial plateau area was similar between men and women (p = 0.22 medially; p = 0.72 laterally). Tibial coverage by the meniscus was similar between men and women (50% medially; 58% laterally), but "physiological" medial meniscal extrusion was greater in women (1.83 ± 1.06mm) than in men (1.24mm ± 1.18mm; p = 0.011).</p> <p>Conclusions</p> <p>These data suggest that meniscus surface area strongly scales with (ipsilateral) tibial plateau area across both sexes, and that tibial coverage by the meniscus is similar between men and women.</p

    Rotational knee laxity: Reliability of a simple measurement device in vivo

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Double bundle ACL reconstruction has been demonstrated to decrease rotational knee laxity. However, there is no simple, commercially-available device to measure knee rotation. The investigators developed a simple, non-invasive device to measure knee rotation. In conjunction with a rigid boot to rotate the tibia and a force/moment sensor to allow precise determination of torque about the knee, a magnetic tracking system measures the axial rotation of the tibia with respect to the femur. This device has been shown to have acceptable levels of test re-test reliability to measure knee rotation in cadaveric knees.</p> <p>Methods</p> <p>The objective of this study was to determine reliability of the device in measuring knee rotation of human subjects. Specifically, the intra-tester reliability within a single testing session, test-retest reliability between two testing sessions, and inter-tester reliability were assessed for 11 male subjects with normal knees.</p> <p>Results</p> <p>The 95% confidence interval for rotation was less than 5° for intra-tester, test-retest, and inter-tester reliability, and the standard error of measurement for the differences between left and right knees was found to be less than 3°.</p> <p>Conclusion</p> <p>It was found that the knee rotation measurements obtained with this device have acceptable limits of reliability for clinical use and interpretation.</p
    corecore