25 research outputs found

    Manual correction of semi-automatic three-dimensional echocardiography is needed for right ventricular assessment in adults; validation with cardiac magnetic resonance

    Get PDF
    Background: Three-dimensional echocardiography (3DE) and semi-automatic right ventricular delineation has been proposed as an appropriate method for right ventricle (RV) evaluation. We aimed to examine how manual correction of semi-automatic delineation influences the accuracy of 3DE for RV volumes and function in a clinical adult setting using cardiac magnetic resonance (CMR) as the reference method. We also examined the feasibility of RV visualization with 3DE. Methods: 62 non-selected patients were examined with 3DE (Sonos 7500 and iE33) and with CMR (1.5T). Endocardial RV contours of 3DE-images were semi-automatically assessed and manually corrected in all patients. End-diastolic (EDV), end-systolic (ESV) volumes, stroke volume (SV) and ejection fraction (EF) were computed. Results: 53 patients (85%) had 3DE-images feasible for examination. Correlation coefficients and Bland Altman biases between 3DE with manual correction and CMR were r = 0.78, -22 +/- 27 mL for EDV, r = 0.83, -7 +/- 16 mL for ESV, r = 0.60, -12 +/- 18 mL for SV and r = 0.60, -2 +/- 8% for EF (p < 0.001 for all r-values). Without manual correction r-values were 0.77, 0.77, 0.70 and 0.49 for EDV, ESV, SV and EF, respectively (p < 0.001 for all r-values) and biases were larger for EDV, SV and EF (-32 +/- 26 mL, -21 +/- 15 mL and -6 +/- 9%, p <= 0.01 for all) compared to manual correction. Conclusion: Manual correction of the 3DE semi-automatic RV delineation decreases the bias and is needed for acceptable clinical accuracy. 3DE is highly feasible for visualizing the RV in an adult clinical setting

    Measurements of left ventricular myocardial longitudinal systolic displacement using spectral and colour tissue Doppler: time for a reassessment?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Echocardiographic measurements of left ventricular (LV) myocardial displacement may produce different results depending on the choice of employed modality and subjective adjustments during data acquisition and analysis.</p> <p>Methods</p> <p>In this study, left ventricular longitudinal systolic displacement was quantified in 57 patients (31 women and 26 men, 50 ± 16 years) using colour (colour TD) and spectral tissue Doppler (spectral TD) before and after temporal filtering (30 to 70 milliseconds in 20-millisecond steps) and changed offline gain saturation (0%, 50% and 100%), respectively. The results were compared with those obtained with anatomic M-mode.</p> <p>Results</p> <p>Whereas only minor differences occurred between the results of colour TD and anatomic M-mode measurements, spectral TD significantly overestimated the results obtained with both these methods. However, the limits of agreement between the results produced by all three studied methods were not clinically acceptable in any of the cases. The spectral TD displacement values increased along with increasing offline gain saturation whereas the effect of temporal filtering on colour Doppler measurements was insignificant.</p> <p>Conclusion</p> <p>Measurements of LV myocardial longitudinal displacement employing spectral TD, colour TD or anatomic M-mode produce different results, thus discouraging interchangeable use of these modalities. Whereas the results of spectral TD measurements can be significantly altered by changing offline gain setting, the effect of temporal filtering on colour TD measurements is insignificant, a fact that increases clinical practicality of the latter method.</p

    Brain natriuretic peptide is related to diastolic dysfunction whereas urinary albumin excretion rate is related to left ventricular mass in asymptomatic type 2 diabetes patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aims of this study were to estimate the prevalence of left ventricular systolic (LVSD) and diastolic (LVDD) dysfunction, and to test if BNP and urinary albumin excretion rate (AER) are related to LVSD, LVD and left ventricular mass (LVM) in asymptomatic type 2 diabetes patients.</p> <p>Methods</p> <p>Presence of LVSD, LVDD and LVM, determined with echocardiography, was related to levels of BNP and AER in 153 consecutive asymptomatic patients with type 2 diabetes.</p> <p>Results</p> <p>LVSD was present in 6.1% of patients whereas 49% (29% mild, 19% moderate and 0.7% severe) had LVDD and 9.4% had left ventricular hypertrophy. Increasing age (P < 0.0001) was the only independent variable related to mild LVDD whereas increasing BNP (P = 0.01), systolic blood pressure (P = 0.01), age (P = 0.003) and female gender (P = 0.04) were independent determinants of moderate to severe LVDD. AER (P = 0.003), age (P = 0.01) and male gender (P = 0.006) were directly and independently related to LVM.</p> <p>Conclusion</p> <p>About half of asymptomatic type 2 diabetes patients have LVDD. Of those, more than one third display moderate LVDD pattern paralleled by increases in BNP, suggesting markedly increased risk of heart failure, especially in females, whereas AER and male sex are related to LVM.</p

    Visually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Visual assessment of left ventricular ejection fraction (LVEF) is often used in clinical routine despite general recommendations to use quantitative biplane Simpsons (BPS) measurements. Even thou quantitative methods are well validated and from many reasons preferable, the feasibility of visual assessment (eyeballing) is superior. There is to date only sparse data comparing visual EF assessment in comparison to quantitative methods available. The aim of this study was to compare visual EF assessment by two-dimensional echocardiography (2DE) and triplane echocardiography (TPE) using quantitative real-time three-dimensional echocardiography (RT3DE) as the reference method.</p> <p>Methods</p> <p>Thirty patients were enrolled in the study. Eyeballing EF was assessed using apical 4-and 2 chamber views and TP mode by two experienced readers blinded to all clinical data. The measurements were compared to quantitative RT3DE.</p> <p>Results</p> <p>There were an excellent correlation between eyeballing EF by 2D and TP vs 3DE (r = 0.91 and 0.95 respectively) without any significant bias (-0.5 ± 3.7% and -0.2 ± 2.9% respectively). Intraobserver variability was 3.8% for eyeballing 2DE, 3.2% for eyeballing TP and 2.3% for quantitative 3D-EF. Interobserver variability was 7.5% for eyeballing 2D and 8.4% for eyeballing TP.</p> <p>Conclusion</p> <p>Visual estimation of LVEF both using 2D and TP by an experienced reader correlates well with quantitative EF determined by RT3DE. There is an apparent trend towards a smaller variability using TP in comparison to 2D, this was however not statistically significant.</p

    Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation

    Get PDF
    BACKGROUND: Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter- and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF. METHODS: A total of 78 patients were included in this study. Fifty-five with sinus rhythm (group A) and 23 having AF (group B). 4B and SB 3DE was performed in all patients. LV volumes and EF was determined by these two modalities and inter- and intraobserver variability was analyzed. RESULTS: SB modality showed significantly lower inter- and intraobserver variability in group B in comparison to 4B when measuring LV volumes and EF, except for end-systolic volume (ESV) in intraobserver analysis. There were significant differences when calculating the LV volumes (p<0.001) and EF (p<0.05) with SB in comparison to 4B in group B. CONCLUSION: Single-beat three-dimensional full volume acquisition seems to be superior to four-beat ECG-gated acquisition in measuring left ventricular volumes and ejection fraction in patients having atrial fibrillation. The variability is significantly lower both for ejection fraction and left ventricular volumes

    Flow-volume loops derived from three-dimensional echocardiography: a novel approach to the assessment of left ventricular hemodynamics

    Get PDF
    BACKGROUND: This study explores the feasibility of non-invasive evaluation of left ventricular (LV) flow-volume dynamics using 3-dimensional (3D) echocardiography, and the capacity of such an approach to identify altered LV hemodynamic states caused by valvular abnormalities. METHODS: Thirty-one patients with moderate-severe aortic (AS) and mitral (MS) stenoses (21 and 10 patients, respectively) and 10 healthy volunteers underwent 3D echocardiography with full volume acquisition using Philips Sonos 7500 equipment. The digital 3D data were post- processed using TomTec software. LV flow-volume loops were subsequently constructed for each subject by plotting instantaneous LV volume data sampled throughout the cardiac cycle vs. their first derivative representing LV flow. After correction for body surface area, an average flow-volume loop was calculated for each subject group. RESULTS: Flow-volume loops were obtainable in all subjects, except 3 patients with AS. The flow-volume diagrams displayed clear differences in the form and position of the loops between normal individuals and the respective patient groups. In patients with AS, an "obstructive" pattern was observed, with lower flow values during early systole and larger end-systolic volume. On the other hand, patients with MS displayed a "restrictive" flow-volume pattern, with reduced diastolic filling and smaller end-diastolic volume. CONCLUSION: Non-invasive evaluation of LV flow-volume dynamics using 3D-echocardiographic data is technically possible and the approach has a capacity to identify certain specific types of alteration of LV flow-volume pattern caused by valvular abnormalities, thus reflecting underlying hemodynamic states specific for these abnormalities

    Head to head comparisons of two modalities of perfusion adenosine stress echocardiography with simultaneous SPECT

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Real-time perfusion (RTP) contrast echocardiography can be used during adenosine stress echocardiography (ASE) to evaluate myocardial ischemia. We compared two different types of RTP power modulation techniques, angiomode (AM) and high-resolution grayscale (HR), with <sup>99m</sup>Tc-tetrofosmin single-photon emission computed tomography (SPECT) for the detection of myocardial ischemia.</p> <p>Methods</p> <p>Patients with known or suspected coronary artery disease (CAD), admitted to SPECT, were prospectively invited to participate. Patients underwent RTP imaging (SONOS 5500) using AM and HR during Sonovue<sup>® </sup>infusion, before and throughout the adenosine stress, also used for SPECT. Analysis of myocardial perfusion and wall motion by RTP-ASE were done for AM and HR at different time points, blinded to one another and to SPECT. Each segment was attributed to one of the three main coronary vessel areas of interest.</p> <p>Results</p> <p>In 50 patients, 150 coronary areas were analyzed by SPECT and RTP-ASE AM and HR. SPECT showed evidence of ischemia in 13 out of 50 patients. There was no significant difference between AM and HR in detecting ischemia (p = 0.08). The agreement for AM and HR, compared to SPECT, was 93% and 96%, with Kappa values of 0.67 and 0.75, respectively (p < 0.001).</p> <p>Conclusion</p> <p>There was no significant difference between AM and HR in correctly detecting myocardial ischemia as judged by SPECT. This suggests that different types of RTP modalities give comparable data during RTP-ASE in patients with known or suspected CAD.</p

    Quantitative detection of myocardial ischaemia by stress echocardiography; a comparison with SPECT

    Get PDF
    <p>Abstract</p> <p>Aims</p> <p>Real-time perfusion (RTP) adenosine stress echocardiography (ASE) can be used to visually evaluate myocardial ischaemia. The RTP power modulation technique angio-mode (AM), provides images for off-line perfusion quantification using Qontrast<sup>® </sup>software, generating values of peak signal intensity (A), myocardial blood flow velocity (β) and myocardial blood flow (Axβ). By comparing rest and stress values, their respective reserve values (A-r, β-r, Axβ-r) are generated. We evaluated myocardial ischaemia by RTP-ASE Qontrast<sup>® </sup>quantification, compared to visual perfusion evaluation with <sup>99m</sup>Tc-tetrofosmin single-photon emission computed tomography (SPECT).</p> <p>Methods and Results</p> <p>Patients admitted to SPECT underwent RTP-ASE (SONOS 5500) using AM during Sonovue<sup>® </sup>infusion, before and throughout adenosine stress, also used for SPECT. Visual myocardial perfusion and wall motion analysis, and Qontrast<sup>® </sup>quantification, were blindly compared to one another and to SPECT, at different time points off-line.</p> <p>We analyzed 201 coronary territories (left anterior descendent [LAD], left circumflex [LCx] and right coronary [RCA] artery territories) in 67 patients. SPECT showed ischaemia in 18 patients and 19 territories. Receiver operator characteristics and kappa values showed significant agreement with SPECT only for β-r and Axβ-r in all segments: area under the curve 0.678 and 0.665; P < 0.001 and < 0.01, respectively. The closest agreements were seen in the LAD territory: kappa 0.442 for both β-r and Axβ-r; P < 0.01. Visual evaluation of ischaemia showed good agreement with SPECT: accuracy 93%; kappa 0.67; P < 0.001; without non-interpretable territories.</p> <p>Conclusion</p> <p>In this agreement study with SPECT, RTP-ASE Qontrast<sup>® </sup>quantification of myocardial ischaemia was less accurate and less feasible than visual evaluation and needs further development to be clinically useful.</p

    Comparison of different views with three-dimensional echocardiography: apical views offer superior visualization compared with parasternal and subcostal views.

    No full text
    Studies seeking to validate real-time three-dimensional echocardiography (3DE) with regard to cardiac function and dimensions have almost exclusively used apical views. However, it has never been examined whether apical views are preferable to parasternal or subcostal views. In the present study, we compared the feasibility of 3DE volumetric measurements of the four heart chambers in three different views. We included 40 patients planned for a routine two-dimensional transthoracic echocardiography examination (2DE). All patients were scanned with both 2DE and 3DE (Sonos 7500; Philips Medical Systems Andover, MA, USA). Parasternal, apical and subcostal views were used for 3DE. Volumes were calculated using manual tracing in 16 planes. 2DE was performed in parasternal longaxis, subcostal and apical four- and two-chamber views. Manual tracing was used for area calculations. To be judged fully traceable, 5/6 (85%) or more of the ventricular and atrial walls had to be adequately visualized in each plane. The left ventricle and left atrium were adequately visualized in the 3DE apical view in 34 (85%) and 40 (100%) patients, respectively. Visualization of the right atrium was adequate in 31 (78%) patients, whereas the right ventricle was adequately visualized in only 12 (30%) patients. The apical view of 3DE provided superior visualization of all four heart chambers compared with the parasternal and subcostal views, when applying a slight off-axis approach for both ventricles when needed. Thus, in the present study, there was no incremental value of assessment of chamber volumes in the parasternal and subcostal views
    corecore