929 research outputs found

    Detection of liquid xenon scintillation light with a Silicon Photomultiplier

    Full text link
    We have studied the feasibility of a silicon photomultiplier (SiPM) to detect liquid xenon (LXe) scintillation light. The SiPM was operated inside a small volume of pure LXe, at -95 degree Celsius, irradiated with an internal Am-241 alpha source. The gain of the SiPM at this temperature was estimated to be 1.8 x 10^6 with bias voltage at 52 V. Based on the geometry of the setup, the quantum efficiency of the SiPM was estimated to be 22% at the Xe wavelength of 178 nm. The low excess noise factor, high single photoelectron detection efficiency, and low bias voltage of SiPMs make them attractive alternative UV photon detection devices to photomultiplier tubes (PMTs) for liquid xenon detectors, especially for experiments requiring a very low energy detection threshold, such as neutralino dark matter searches

    Performance of a cryogenic system prototype for the XENON1T Detector

    Full text link
    We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K as target and detection medium for a dark matter search. In this paper we report results on the cryogenic system performance focusing on the dynamics of the gas circulation-purification through a heated getter, at flow rates above 50 Standard Liter per Minute (SLPM). A maximum flow of 114 SLPM has been achieved, and using two heat exchangers in parallel, a heat exchange efficiency better than 96% has been measured

    Characterization of the Hamamatsu S8664 Avalanche Photodiode for X-Ray and VUV-light detection

    Full text link
    We present the first operation of the Avalanche Photodiode (APD) from Hamamatsu to xenon scintillation light and to direct X-rays of 22.1 keV and 5.9 keV. A large non-linear response was observed for the direct X-ray detection. At 415 V APD bias voltage it was of about 30 % for 22.1 keV and about 45 % for 5.9 keV. The quantum efficiency for 172 nm photons has been measured to be 69 +/- 15 %.Comment: 11 pages, 3 figures, submitted to Elsevie

    A study of the etapipi channel produced in central pp interactions at 450 GeV/c

    Get PDF
    The reaction pp -> pf (eta pi pi) ps has been studied at 450 GeV/c. There is clear evidence for an a2(1320)pi decay mode of the eta2(1645) and eta2(1870). In addition, there is evidence for an a0(980)pi$ decay mode of both resonances and an f2(1270)eta decay mode of the eta2(1870). No evidence is found for a JPC = 2++ a2(1320)pi wave.Comment: 15 pages, Latex, 4 Figures Branching ratio a2pi /f2 eta correcte

    3D Position Sensitive XeTPC for Dark Matter Search

    Get PDF
    The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.Comment: Presented at the 7th UCLA Symposium on "Sources and Detection of Dark Matter and Dark Energy in the Universe

    A study of the f0(1370), f0(1500), f0(2000) and f2(1950) observed in the centrally produced 4pi final states

    Get PDF
    The production and decay properties of the f0(1370), f0(1500), f0(2000) and f2(1950) have been studied in central pp interactions at 450 GeV/c. The dPT, phi and |t| distributions of these resonances are presented. For the J = 0 states, the f0(1370) and f0(2000) have similar dPT and phi dependences. These are different to the dPT and phi dependences of the f0(980), f0(1500) and f0(1710). For the J = 2 states the f2(1950) has different dependences to the f2(1270) and f2'(1520). This shows that the dPT and phi dependences are not just J phenomena.Comment: 14 pages, Latex, 4 Figure

    Constraints on inelastic dark matter from XENON10

    Full text link
    It has been suggested that dark matter particles which scatter inelastically from detector target nuclei could explain the apparent incompatibility of the DAMA modulation signal (interpreted as evidence for particle dark matter) with the null results from CDMS-II and XENON10. Among the predictions of inelastically interacting dark matter are a suppression of low-energy events, and a population of nuclear recoil events at higher nuclear recoil equivalent energies. This is in stark contrast to the well-known expectation of a falling exponential spectrum for the case of elastic interactions. We present a new analysis of XENON10 dark matter search data extending to Enr=75_{nr}=75 keV nuclear recoil equivalent energy. Our results exclude a significant region of previously allowed parameter space in the model of inelastically interacting dark matter. In particular, it is found that dark matter particle masses mχ150m_{\chi}\gtrsim150 GeV are disfavored.Comment: 8 pages, 4 figure

    A search for light dark matter in XENON10 data

    Full text link
    We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic dark matter interpretations of excess low-energy events observed by CoGeNT and CRESST-II, as well as the DAMA annual modulation signal.Comment: Manuscript identical to v2 (published version) but also contains erratum. Note v3==v2 but without \linenumber
    corecore