48 research outputs found

    Assessment of linear-scale indices for perimetry in terms of progression in early glaucoma

    Get PDF
    AbstractCurrently, global indices that summarize the visual field combine sensitivities on a logarithmic (decibel) scale. Recent structure–function models for glaucoma suggest that contrast sensitivity should be converted to a linear scale before averaging across visual field locations, to better relate sensitivity with the number of surviving retinal ganglion cells (RGCs). New indices designed to represent the number of RGCs already lost are described. At least one was found to be a significantly better predictor of subsequent rate of change than traditional Mean Deviation (p=0.014) in participants with glaucomatous optic neuropathy. Issues concerning the creation of optimal global indices are discussed

    Nonlinear Trend Analysis of Longitudinal Pointwise Visual Field Sensitivity in Suspected and Early Glaucoma

    Get PDF
    Purpose: We have shown previously that a nonlinear exponential model fits longitudinal series of mean deviation (MD) better than a linear model. This study extends that work to investigate the mode (linear versus nonlinear) of change for pointwise sensitivities. Methods: Data from 475 eyes of 244 clinically managed participants were analyzed. Sensitivity estimates at each test location were fitted using two-level linear and nonlinear mixed effects models. Sensitivity on the last test date was forecast using a model fit from the earlier test dates in the series. The means of the absolute prediction errors were compared to assess accuracy, and the root means square (RMS) of the prediction errors were compared to assess precision. Results: Overall, the exponential model provided a significantly better fit (P , 0.05) to the data at the majority of test locations (69%). The exponential model fitted the data significantly better at 85% of locations in the upper hemifield and 58% of locations in the lower hemifield. The rate of visual field (VF) deterioration in the upper hemifield was more rapid (mean, À0.21 dB/y; range, À0.28 to À0.13) than in the lower hemifield (mean, À0.14 dB/y; range, À0.2 to À0.09). Conclusions: An exponential model may more accurately track pointwise VF change, at locations damaged by glaucoma. This was more noticeable in the upper hemifield where the VF changed more rapidly. However, linear and exponential models were similar in their ability to forecast future VF status

    The Effect of Stimulus Size on the Reliable Stimulus Range of Perimetry

    Get PDF
    Purpose: Automated perimetry uses a 3.5 log unit (35dB) range of stimulus contrasts to assess function within the visual field. Using 'Size III' stimuli (0.438), presenting stimuli within the highest 15dB of available contrast may not increase the response probability at locations damaged by glaucoma, due to retinal ganglion cell response saturation. This experiment examines the effect of instead using 'Size V' (1.728) stimuli. Methods: Luminance increment thresholds for circular spot stimuli of each stimulus size were measured in 35 participants (mean deviation À20.9 to À3.4 dB, ages 52-87) using the method of constant stimuli, at four locations per participant. Frequency-ofseeing curves were fit at each size and location, with three free parameters: mean, standard deviation, and asymptotic maximum response probability. These were used to estimate the contrasts to which each participant would respond on 25% of presentations (c25). Results: Using segmented orthogonal regression, the maximum observed response probabilities for size III stimuli began to decline at c25 ¼ 25.2 dB (95% confidence interval 23.3-29.0 dB from bootstrap resampling). This decline started at similar contrast for the size V stimulus: c25 ¼ 25.0dB (22.0-26.8 dB). Among locations at which the sensitivity was above these split-points for both stimulus sizes, c25 averaged 5.6 dB higher for size V than size III stimuli. Conclusions: The lower limit of the reliable stimulus range did not differ significantly between stimulus sizes. However, more locations remained within the reliable stimulus range when using the size V stimulus. Translational Relevance: Size V stimuli enable reliable clinical testing later into the glaucomatous disease process

    Predicting Progressive Glaucomatous Optic Neuropathy Using Baseline Standard Automated Perimetry Data

    Get PDF
    PURPOSE. To test the hypothesis that specific locations and patterns of threshold findings within the visual field have predictive value for progressive glaucomatous optic neuropathy (pGON). METHODS. Age-adjusted standard automated perimetry thresholds, along with other clinical variables gathered at the initial examination of 168 individuals with high-risk ocular hypertension or early glaucoma, were used as predictors in a classification tree model. The classification variable was a determination of pGON, based on longitudinally gathered stereo optic nerve head photographs. Only data for the worse eye of each individual were included. Data from 100 normal subjects were used to test the specificity of the models. RESULTS. Classification tree models suggest that patterns of baseline visual field findings are predictive of pGON with sensitivity 65% and specificity 87% on average. Average specificity when data from normal subjects were run on the models was 69%. CONCLUSIONS. Classification trees can be used to determine which visual field locations are most predictive of poorer prognosis for pGON. Spatial patterns within the visual field convey useable predictive information, in most cases when thresholds are still well within the classically defined normal range. (Invest Ophthalmol Vis Sci. 2009;50:674 -680

    Variability in Short-Wavelength Automated Perimetry Among Peri- or Postmenopausal Women: A Dependence on Phyto-Oestrogen Consumption?

    Get PDF
    Purpose:  To determine whether the hill of vision for Short-Wavelength Automated Perimetry (SWAP) is shallower for women who consume phyto-oestrogen-rich foods than for women who do not. Methods:  Visual field data were compared for two groups of healthy amenorrhoeic women 48–69 years-old with normal vision and not using hormone replacement: (1) 24 subjects who reported consuming soy and/or flax products and (2) 20 subjects who reported not consuming these products. Two types of 24-2 visual fields were measured: (1) Full Threshold SWAP and (2) a white-on-white (W/W) field obtained using a Swedish Interactive Threshold Algorithm (SITA Standard). Results:  The reduction of SWAP sensitivity from the centre of the field (4 loci, mean eccentricity = 4.2°) to the periphery (20 loci, mean eccentricity = 21.9°) was less for soy/flax consumers than for nonconsumers, both with age-referencing (mean difference = 1.7 dB, p = 0.018) and without (p = 0.012). Corresponding distinctions existed for the SWAP – W/W difference, and there was minimal effect for W/W fields alone. The peripheral age-referenced SWAP sensitivities averaged 2.5 dB higher for consumers than nonconsumers (p = 0.022). Conclusion:  The between-group distinctions are consistent with the possibility (derived from the women’s health literature) that phyto-oestrogens may counteract a decline of short-wavelength-sensitive cone-mediated response among postmenopausal women. These results suggest another potential application for SWAP outside its original intended purpose as a glaucoma test. Future studies should assess whether phyto-oestrogen consumption is most beneficial for women who are sufficiently young and/or not too far beyond menopause

    Cup Size Predicts Subsequent Functional Change in Early Glaucoma

    No full text

    Assessment of false positives with the Humphrey Field Analyzer II perimeter with the SITA Algorithm

    No full text
    PURPOSE. To evaluate the effects of false-positive (FP) response errors on mean deviation (MD), pattern standard deviation (PSD), glaucoma hemifield test (GHT), and test duration in the Humphrey Field Analyzer's (HFA II) Swedish Interactive Threshold Algorithm (SITA; Carl Zeiss Meditec, Inc., Dublin, CA). METHODS. Five individuals with glaucoma (ages 52, 63, 69, 77, and 78 years) and five individuals with normal, healthy eyes (ages 25, 34, 43, 45, and 52 years), participated in the study. Each subject was experienced in automated perimetry and performed multiple, monocular baseline SITA-standard (SITA-S) 24-2 visual field tests. In addition, normal subjects completed SITA-S 24-2 field examinations in which known frequencies of FP error were introduced (0%, 5%, 10%, 20%, or 33% frequency). Likewise, the subjects with glaucoma completed visual field examinations with 0%, 20%, and 33% error introduced during the test. RESULTS. Reported FP errors were significantly lower than the introduced frequency of error. The SITA algorithm more accurately identified FP errors when the MD and PSD diverged from normal. Test duration increased as introduced error frequencies increased. The Statpac single-field analyses indicated that two thirds of the tests with introduced errors produced a "low-patient-reliability" determination. CONCLUSIONS. HFA II SITA-S underestimates patients' FP errors, particularly among normal patients. High FP error frequencies can have adverse effects on MD and PSD, leading clinicians and researchers to an inaccurate determination of the amount and severity of visual field loss. (Invest Ophthalmol Vis Sci. 2006; 47:4632-4637

    The Nose Knows: Aroma, but Not THC Mediates the Subjective Effects of Smoked and Vaporized Cannabis Flower

    No full text
    Previous studies have shown that cannabis consumers are willing to pay more money for higher-quality products; however, the definition of “quality” cannabis has not been defined. Despite the known health risks of THC overuse, THC potency has been adopted as the primary market-driving feature of cannabis products. The purpose of this study was to objectively identify features of cannabis that contribute to its appealing subjective effects. In the course of conducting cannabis competitions, commercially available cannabis inflorescences were distributed to healthy volunteers (“judges”) in a randomized, double-blind fashion. Anonymous online survey data about the subjective effects of each cannabis sample were analyzed independently, by researchers not involved with the competitions. Pleasant subjective aroma (but not terpene expression, THC potency, or THC dose) was positively correlated with pleasant subjective effects. There was also a moderate but significant negative association between the amount of cannabis consumed and subjective appeal. These results suggest that, unlike THC potency, pleasant aroma is predictive of pleasant subjective effects. Similar to other agricultural commodities such as coffee and tea, aroma appears to be a robust indicator of the quality of cannabis inflorescence. These findings have wide-reaching public health implications, given the well-established health risks of THC overuse
    corecore