10 research outputs found

    The effect of time-to-surgery on outcome in elderly patients with proximal femoral fractures

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Whether reducing time-to-surgery for elderly patients suffering from hip fracture results in better outcomes remains subject to controversial debates.</p> <p>Methods</p> <p>As part of a prospective observational study conducted between January 2002 and September 2003 on hip-fracture patients from 268 acute-care hospitals all over Germany, we investigated the relationship of time-to-surgery with frequency of post-operative complications and one-year mortality in elderly patients (age ≥65) with isolated proximal femoral fracture (femoral neck fracture or pertrochanteric femoral fracture). Patients with short (≤12 h), medium (> 12 h to ≤36 h) and long (> 36 h) times-to-surgery, counting from the time of the fracture event, were compared for patient characteristics, operative procedures, post-operative complications and one-year mortality.</p> <p>Results</p> <p>Hospital data were available for 2916 hip-fracture patients (mean age (SD) in years: 82.1 (7.4), median age: 82; 79.7% women). Comparison of groups with short (n = 802), medium (n = 1191) and long (n = 923) time-to-surgery revealed statistically significant differences in a few patient characteristics (age, American Society of Anesthesiologists ratings classification and type of admission) and in operative procedures (total hip endoprosthesis, hemi-endoprosthetic implants, other osteosynthetic procedures). However, comparison of these same groups for frequency of postoperative complications revealed only some non-significant associations with certain complications such as post-operative bleeding requiring treatment (early surgery patients) and urinary tract infections (delayed surgery patients). Both unadjusted rates of one-year all-cause mortality (between 18.1% and 20.5%), and the multivariate-adjusted hazard ratios (HR for time-to-surgery: 1.04; p = 0.55) showed no association between mortality and time-to-surgery.</p> <p>Conclusion</p> <p>Although this study found a trend toward more frequent post-operative complications in the longest time-to-surgery group, there was no effect of time-to-surgery on mortality. Shorter time-to-surgery may be associated with somewhat lower rates of post-operative complications such as decubitus ulcers, urinary tract infections, thromboses, pneumonia and cardiovascular events, and with somewhat higher rates of others such as post-operative bleeding or implant complications.</p

    Mass loss of four commercially available heat-polymerized acrylic resins after toothbrushing with three different dentifrices

    Get PDF
    The association between a toothbrush and a dentifrice is the most used denture cleaning method. The purpose of this study was to evaluate the abrasiveness of specific and non-specific denture cleaning dentifrices on different heat-polymerized acrylic resins. Sixteen specimens (90x30x3mm) of each acrylic resin (QC-20, Lucitone 550, Clássico, Vipi-Cril) were prepared and randomly assigned to 4 groups: 1: control (distilled water), 2: Colgate, 3: Bonyplus and 4: Dentu-Creme. The specimens were subjected to simulated toothbrushing in an automatic brushing machine using 35,600 brush strokes for each specimen. Brushing abrasion run at a 200-g load with the specimens immersed in 2:1 dentifrice/water slurry. Specimens were reconditioned to constant mass and the mass loss (mg) was evaluated. Data were analyzed by 2-way ANOVA and Tukey's test (a=0.05). Analysis of dentifrices' abrasive particles was made by scanning electron microscopy. Colgate produced the greatest mass reduction (42.44 mg, p<0.05), followed by Dentu-Creme (33.60 mg). Bonyplus was the less abrasive (19.91 mg), similar to the control group (19.69 mg) (p>0.05). The mass loss values indicated that QC-20 (33.13 mg) and Lucitone 550 (33.05 mg) resins were less (p<0.05) resistant to abrasion than Clássico (26.04 mg) and Vipi-Cril (23.43 mg). In conclusion, Colgate produced the greatest abrasion. Specific dentifrices for dentures tend to cause less damage to acrylic resins
    corecore