69 research outputs found

    An in vitro comparison of different adhesive strategies on the micro push-out bond strength of a glass fiber post

    Get PDF
    Objectives: To evaluate in vitro the push-out bond strengths of a glass fiber post adhesively luted with self-etching resin based and self-adhesive luting cements, as well as modified application procedure of self-adhesive luting cements in combination with single step self-etch adhesives. Materials and methods: Fifty single-rooted human maxillary central incisor teeth were endodontically treated and divided into five groups (n=10). Glass fiber posts (RelyX Fiber Post) were cemented with the following materials: group 1: ED Primer II/Panavia F 2.0 (PAN); group 2: RelyX Unicem (RU); group 3: Maxcem (MC); group 4: Adper Prompt L-Pop (PLP)/RelyX Unicem; group 5: Optibond all-in-one (OB)/Maxcem. Bonded specimens were cut (1-mm-thick sections) and push-out tests were performed (crosshead-speed, 0.5 mm/min). Data were analyzed by one-way ANOVA followed by the Tukey-HSD test for post hoc comparisons at ? = 0.05. Results: The highest bond strength was recorded for groups 4 and 2, with no statistically significant differences among them (p>0.05). Group 4 showed significantly higher bond strength than group 1 (p<0.001), group 3 (p<0.0001) and group 5 (p<0.0001). Group 1 showed significantly higher bond strength than the group 3 (p<0.05). No statistically significant differences were observed among group 1 and group 2, group 1 and group 5, group 3 and group 5. Group 3 showed significantly lower push-out bond strength than the all other luting strategies except for the group 5. Conclusions: The push-out bond strength values of modified application procedure of self-adhesive luting cements (RU and MC) in combination with single step self-etch dentin adhesives (PLP and OB) did not improve the push-out bond strength of fiber post when compared with those where the conventional use of self-adhesive cements. © Medicina Oral S. L

    Smoking addiction among university students in Istanbul

    No full text
    In this study, we investigated smoking addiction and some risk factors among university students in Istanbul. A questionnaire survey of 236 university students studying in Istanbul Medical Faculty (n: 148) and other faculties (n: 88) was performed with cross-sectional and responding-under-observation methods in March-May 1999. Thirty-six per cent of the university students with mean age 24.0 (2.9 were addicted to smoking (n: 85): 41.3% males and 26.7% females; 67.5% were using imported and 32.5% were using local product cigarettes. Of the subjects, 18.1% were smoking 1-10 cigarettes a day, 61.4% 11-20 cigarettes a day and 20.5% more than 20 cigarettes a day. When alcohol and smoking addiction were compared with logistic regression analysis, with respect to gender, age, school, parents' educational levels, living style and the sources of income, the risk factor for alcohol addicts was found to be more 2.54 times than smoking addicts (OR = 2.54, 95% CI = 1.38-4.67; p = 0.003). The study has emphasized the association of alcohol and smoking addiction in university students and the prevalence of smoking addiction among adolescent females

    Effect of different adhesive strategies on the post-operative sensitivity of class I composite restorations

    No full text
    OBJECTIVE: To evaluate the post-operative sensitivity of occlusal restorations using different dentin adhesives performed by an undergraduate and a post-doctorate dentist. MATERIALS AND METHODS: One hundred and eighty-eight molar occlusal restorations were placed in 39 patients (ages between 18 and 30) using 3 different kind of adhesive systems; Optibond FL (OBF), Clearfil Protect Bond (CPB), and iBond (IB) by a post-doctorate dentist or a fifth-year dental student according to the manufacturers’ instructions. Post-operative sensitivity to cold and air was evaluated using a Visual Analog Scale (VAS) after 24 hours, 30, 90, and 180 days. Data were analyzed using the Mann-Whitney U and Friedman tests (P < 0.05). RESULTS: Post-operative sensitivity scores for OBF and CPB were higher for the dental student (P < 0.05), while IB scores did not differ statistical significantly according to the operator (P > 0.05). CONCLUSION: Operator skill and experience appears to play a role in determining the outcome of post-operative sensitivity of multi-step adhesive systems although the post-operative sensitivity was low. It is suggested that the less experienced clinicians (rather than experienced clinicians) should better use the self-etching dentin bonding systems with reduced application steps to minimize the potential risk of post-operative sensitivity of dental adhesives

    Surface hardness of different restorative materials after long-term immersion in sports and energy drinks

    No full text
    The purpose of this study was to evaluate the effect of sports and energy drinks on the surface hardness of different restorative materials over a 6-month period. Forty-two disk-shaped specimens were prepared for each of the four restorative materials tested: Compoglass F, Filtek Z250, Filtek Supreme, and Premise. Specimens were immersed for 2 mm daily, up to 6 months, in six storage solutions (n=7 per material for each solution): distilled water, Powerade, Gatorade, X-IR, Burn, and Red Bull. Surface hardness was measured at baseline, after 1 week, 1 month, and 6 months. Data were analyzed statistically using repeated measures ANOVA followed by the Bonferroni test for multiple comparisons (alpha=0.05). Surface hardness of the restorative materials was significantly affected by both immersion solution and immersion period (p<0.001). All tested solutions induced significant reduction in surface hardness of the restorative materials over a 6-month immersion period

    Surface hardness evaluation of different composite resin materials: influence of sports and energy drinks immersion after a short-term period

    No full text
    Objectives: This study evaluated the effect of sports and energy drinks on the surface hardness of different composite resin restorative materials over a 1-month period. Material and Methods: A total of 168 specimens: Compoglass F, Filtek Z250, Filtek Supreme, and Premise were prepared using a customized cylindrical metal mould and they were divided into six groups (N=42; n=7 per group). For the control groups, the specimens were stored in distilled water for 24 hours at 37 degrees C and the water was renewed daily. For the experimental groups, the specimens were immersed in 5 mL of one of the following test solutions: Powerade, Gatorade, X-IR, Burn, and Red Bull, for two minutes daily for up to a 1-month test period and all the solutions were refreshed daily. Surface hardness was measured using a Vickers hardness measuring instrument at baseline, after 1-week and 1-month. Data were statistically analyzed using Multivariate repeated measure ANOVA and Bonferroni's multiple comparison tests (alpha=0.05). Results: Multivariate repeated measures ANOVA revealed that there were statistically significant differences in the hardness of the restorative materials in different immersion times (p<0.001) in different solutions (p<0.001). The effect of different solutions on the surface hardness values of the restorative materials was tested using Bonferroni's multiple comparison tests, and it was observed that specimens stored in distilled water demonstrated statistically significant lower mean surface hardness reductions when compared to the specimens immersed in sports and energy drinks after a 1-month evaluation period (p<0.001). The compomer was the most affected by an acidic environment, whereas the composite resin materials were the least affected materials. Conclusions: The effect of sports and energy drinks on the surface hardness of a restorative material depends on the duration of exposure time, and the composition of the material

    KNOWLEDGE LEVEL OF 4th AND 6th GRADE MEDICAL SCHOOL STUDENTS ABOUT ADULT TETANUS AND DIPHTERIA VACCINES

    No full text
    Objective: Tetanus and diphtheria (Td) can be prevented between 95-99% if vaccination is done as recommended. Medical school students should know about this high effective vaccine

    Effect of different adhesive strategies on the post-operative sensitivity of class I composite restorations

    No full text
    OBJECTIVE: To evaluate the post-operative sensitivity of occlusal restorations using different dentin adhesives performed by an undergraduate and a post-doctorate dentist. MATERIALS AND METHODS: One hundred and eighty-eight molar occlusal restorations were placed in 39 patients (ages between 18 and 30) using 3 different kind of adhesive systems; Optibond FL (OBF), Clearfil Protect Bond (CPB), and iBond (IB) by a post-doctorate dentist or a fifth-year dental student according to the manufacturers’ instructions. Post-operative sensitivity to cold and air was evaluated using a Visual Analog Scale (VAS) after 24 hours, 30, 90, and 180 days. Data were analyzed using the Mann-Whitney U and Friedman tests (P < 0.05). RESULTS: Post-operative sensitivity scores for OBF and CPB were higher for the dental student (P < 0.05), while IB scores did not differ statistical significantly according to the operator (P > 0.05). CONCLUSION: Operator skill and experience appears to play a role in determining the outcome of post-operative sensitivity of multi-step adhesive systems although the post-operative sensitivity was low. It is suggested that the less experienced clinicians (rather than experienced clinicians) should better use the self-etching dentin bonding systems with reduced application steps to minimize the potential risk of post-operative sensitivity of dental adhesives
    corecore