276 research outputs found
Test of ID carbon-carbon composite prototype tiles for the SPIDER diagnostic calorimeter
Additional heating will be provided to the thermonuclear fusion experiment ITER by injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction at Consorzio RFX in Padova (Italy), the production of negative ions will be studied and optimised. To this purpose the STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) diagnostic will be used to characterise the SPIDER beam during short operation (several seconds) and to verify if the beam meets the ITER requirement regarding the maximum allowed beam non-uniformity (below \ub110%). The most important measurements performed by STRIKE are beam uniformity, beamlet divergence and stripping losses. The major components of STRIKE are 16 1D-CFC (Carbon matrix-Carbon Fibre reinforced Composite) tiles, observed at the rear side by a thermal camera. The requirements of the 1D CFC material include a large thermal conductivity along the tile thickness (at least 10 times larger than in the other directions); low specific heat and density; uniform parameters over the tile surface; capability to withstand localised heat loads resulting in steep temperature gradients. So 1D CFC is a very anisotropic and delicate material, not commercially available, and prototypes are being specifically realised. This contribution gives an overview of the tests performed on the CFC prototype tiles, aimed at verifying their thermal behaviour. The spatial uniformity of the parameters and the ratio between the thermal conductivities are assessed by means of a power laser at Consorzio RFX. Dedicated linear and non-linear simulations are carried out to interpret the experiments and to estimate the thermal conductivities; these simulations are described and a comparison of the experimental data with the simulation results is presented
First hydrogen operation of NIO1: characterization of the source plasma by means of an optical emission spectroscopy diagnostic
NIO1 is a compact and flexible radiofrequency H- ion source, developed by
Consorzio RFX and INFN-LNL. Aim of the experimentation on NIO1 is the
optimization of both the production of negative ions and their extraction and
beam optics. In the initial phase of its commissioning, NIO1 was operated with
nitrogen, but now the source is regularly operated also with hydrogen. To
evaluate the source performances an optical emission spectroscopy diagnostic
was installed. The system includes a low resolution spectrometer in the
spectral range of 300-850 nm and a high resolution (50 pm) one, to study
respectively the atomic and the molecular emissions in the visible range. The
spectroscopic data have been interpreted also by means of a
collisional-radiative model developed at IPP Garching. Besides the diagnostic
hardware and the data analysis methods, the paper presents the first plasma
measurements across a transition to the full H mode, in a hydrogen discharge.
The characteristic signatures of this transition in the plasma parameters are
described, in particular the sudden increase of the light emitted from the
plasma above a certain power threshold.Comment: 3 pages, 2 figures. Contributed paper for the ICIS 2015 conference.
Accepted manuscrip
Characterization of cesium and H-/D- density in the negative ion source SPIDER
The Heating Neutral Beam Injectors (HNBs) for ITER will have to deliver 16.7
MW beams of H/D particles at 1 MeV energy. The beams will be produced from
H-/D- ions, generated by a radiofrequency plasma source coupled to an ion
acceleration system. A prototype of the ITER HNB ion source is being tested in
the SPIDER experiment, part of the ITER Neutral Beam Test Facility at Consorzio
RFX. Reaching the design targets for beam current density and fraction of
coextracted electrons is only possible by evaporating cesium in the source, in
particular on the plasma facing grid (PG) of the acceleration system. In this
way the work function of the surfaces decreases, significantly increasing the
amount of surface reactions that convert neutrals and positive ions into H-/D-.
It is then of paramount importance to monitor the density of negative ions and
the density of Cs in the proximity of the PG. Monitoring the Cs spatial
distribution along the PG is also essential to guarantee the uniformity of the
beam current. In SPIDER, this is possible thanks to the Cavity Ringdown
Spectroscopy (CRDS) and the Laser absorption Spectroscopy diagnostics (LAS),
which provide line-integrated measurements of negative ion density and neutral,
ground state Cs density, respectively. The paper discusses the CRDS and LAS
measurements as a function of input power and of the magnetic and electric
field used to reduce the coextraction of electrons. Negative ion density data
are in qualitative agreement with the results in Cs-free conditions. In
agreement with simulations, Cs density is peaked in the center of the source; a
top/bottom non uniformity is however present. Several effects of plasma on Cs
deposition are presented.Comment: 17 pages, 9 figures. Paper (Preprint) following the poster
contribution at the SOFT 2022 conference. The destination journal is Fusion
Engineering and Desig
Overview of the design of the ITER heating neutral beam injectors
The heating neutral beam injectors (HNBs) of ITER are designed to deliver 16.7MWof 1 MeVD0 or
0.87 MeVH0 to the ITER plasma for up to 3600 s. They will be the most powerful neutral beam\uf0a0(NB)
injectors ever, delivering higher energy NBs to the plasma in a tokamak for longer than any previous
systems have done. The design of the HNBs is based on the acceleration and neutralisation of negative
ions as the efficiency of conversion of accelerated positive ions is so low at the required energy that a
realistic design is not possible, whereas the neutralisation ofH 12 andD 12 remains acceptable ( 4856%).
The design of a long pulse negative ion based injector is inherently more complicated than that of
short pulse positive ion based injectors because:
\u2022 negative ions are harder to create so that they can be extracted and accelerated from the ion source;
\u2022 electrons can be co-extracted from the ion source along with the negative ions, and their
acceleration must be minimised to maintain an acceptable overall accelerator efficiency;
\u2022 negative ions are easily lost by collisions with the background gas in the accelerator;
\u2022 electrons created in the extractor and accelerator can impinge on the extraction and acceleration
grids, leading to high power loads on the grids;
\u2022 positive ions are created in the accelerator by ionisation of the background gas by the accelerated
negative ions and the positive ions are back-accelerated into the ion source creating a massive power
load to the ion source;
\u2022 electrons that are co-accelerated with the negative ions can exit the accelerator and deposit power on
various downstream beamline components.
The design of the ITER HNBs is further complicated because ITER is a nuclear installation which
will generate very large fluxes of neutrons and gamma rays. Consequently all the injector components
have to survive in that harsh environment. Additionally the beamline components and theNBcell,
where the beams are housed, will be activated and all maintenance will have to be performed remotely.
This paper describes the design of theHNBinjectors, but not the associated power supplies, cooling
system, cryogenic system etc, or the high voltage bushingwhich separates the vacuum of the beamline
fromthehighpressureSF6 of the high voltage (1MV) transmission line, through which the power, gas and
coolingwater are supplied to the beam source. Also themagnetic field reduction system is not described
Beamlet scraping and its influence on the beam divergence at the BATMAN Upgrade test facility
For the ITER fusion experiment, two neutral beam injectors are required for plasma heating and current drive. Each injector supplies a power of about 17 MW, obtained from neutralization of 40 A (46 A), 1 MeV (0.87 MeV) negative deuterium (hydrogen) ions. The full beam is composed of 1280 beamlets, formed in 16 beamlet groups, and strict requirements apply to the beamlet core divergence (<7 mrad). The test facility BATMAN Upgrade uses an ITER-like grid with one beamlet group, which consists of 70 apertures. In a joint campaign performed by IPP and Consorzio RFX to better assess the beam optics, the divergence of a single beamlet was compared to a group of beamlets at BATMAN Upgrade. The single beamlet is measured with a carbon fiber composite tile calorimeter and by beam emission spectroscopy, whereas the divergence of the group of beamlets is measured by beam emission spectroscopy only. When increasing the RF power at low extraction voltages, the divergence of the beamlet and of the group of beamlets is continuously decreasing and no inflection point toward an overperveant beam is found. At the same time, scraping of the extracted ion beam at the second grid (extraction grid) takes place at higher RF power, supported by the absence of the normally seen linear behavior between the measured negative ion density in the plasma close to the extraction system and the measured extracted ion current. Beside its influence on the divergence, beamlet scraping needs to be considered for the determination of the correct perveance and contributes to the measured coextracted electron current
Statistical features of edge turbulence in RFX-mod from Gas Puffing Imaging
Plasma density fluctuations in the edge plasma of the RFX-mod device are
measured through the Gas Puffing Imaging Diagnostics. Statistical features of
the signal are quantified in terms of the Probability Distribution Function
(PDF), and computed for several kinds of discharges. The PDFs from discharges
without particular control methods are found to be adequately described by a
Gamma function, consistently with the recent results by Graves et al [J.P.
Graves, et al, Plasma Phys. Control. Fusion 47, L1 (2005)]. On the other hand,
pulses with external methods for plasma control feature modified PDFs. A first
empirical analysis suggests that they may be interpolated through a linear
combination of simple functions. An inspection of the literature shows that
this kind of PDFs is common to other devices as well, and has been suggested to
be due to the simultaneous presence of different mechanisms driving
respectively coherent bursts and gaussian background turbulence. An attempt is
made to relate differences in the PDFs to plasma conditions such as the local
shift of the plasma column. A simple phenomenological model to interpret the
nature of the PDF and assign a meaning to its parameters is also developed.Comment: 27 pages. Published in PPC
On the statistics of edge fluctuations: comparative study between various fusion devices
In this paper we present a statistical study of edge fluctuations taken with
the Gas Puffing Imaging (GPI) diagnostics. We carry out a comparison of GPI
signal from an extensive database including four devices (two Tokamaks and two
Reversed Field Pinches). The data are analyzed in terms of their statistical
moments Skewness and Kurtosis, as done in [B. Labit, et al, Phys. Rev. Lett.
\textbf{98}, 255002 (2007)]. The data align along parabolic curves, although
different from machine to machine, with some spread around the best-fitting
curve. A discussion about the meaning of the parabolic trend as well as the
departure of real data from it is provided. A phenomenological model is finally
provided, attempting to accomodate experimental evidence.Comment: To appear in Plasma Physics and Controlled Fusio
Start of SPIDER operation towards ITER neutral beams
Heating Neutral Beam (HNB) Injectors will constitute the main plasma heating and current drive tool both in ITER and JT60-SA, which are the next major experimental steps for demonstrating nuclear fusion as viable energy source. In ITER, in order to achieve the required thermonuclear fusion power gain Q=10 for short pulse operation and Q=5 for long pulse operation (up to 3600s), two HNB injectors will be needed [1], each delivering a total power of about 16.5 MW into the magnetically-confined plasma, by means of neutral hydrogen or deuterium particles having a specific energy of about 1 MeV. Since only negatively charged particles can be efficiently neutralized at such energy, the ITER HNB injectors [2] will be based on negative ions, generated by caesium-catalysed surface conversion of atoms in a radio-frequency driven plasma source. A negative deuterium ion current of more than 40 A will be extracted, accelerated and focused in a multi-aperture, multi-stage electrostatic accelerator, having 1280 apertures (~ 14 mm diam.) and 5 acceleration stages (~200 kV each) [3]. After passing through a narrow gas-cell neutralizer, the residual ions will be deflected and discarded, whereas the neutralized particles will continue their trajectory through a duct into the tokamak vessels to deliver the required heating power to the ITER plasma for a pulse duration of about 3600 s. Although the operating principles and the implementation of the most critical parts of the injector have been tested in different experiments, the ITER NBI requirements have never been simultaneously attained. In order to reduce the risks and to optimize the design and operating procedures of the HNB for ITER, a dedicated Neutral Beam Test Facility (NBTF) [4] has been promoted by the ITER Organization with the contribution of the European Union\u2019s Joint Undertaking for ITER and of the Italian Government, with the participation of the Japanese and Indian Domestic Agencies (JADA and INDA) and of several European laboratories, such as IPP-Garching, KIT-Karlsruhe, CCFE-Culham, CEA-Cadarache. The NBTF, nicknamed PRIMA, has been set up at Consorzio RFX in Padova, Italy [5]. The planned experiments will verify continuous HNB operation for one hour, under stringent requirements for beam divergence (< 7 mrad) and aiming (within 2 mrad). To study and optimise HNB performances, the NBTF includes two experiments: MITICA, full-scale NBI prototype with 1 MeV particle energy and SPIDER, with 100 keV particle energy and 40 A current, aiming at testing and optimizing the full-scale ion source. SPIDER will focus on source uniformity, negative ion current density and beam optics. In June 2018 the experimental operation of SPIDER has started
- …